Get support for Dell PowerConnect 6224

Dell PowerConnect 6224 Support Question

Dell PowerConnect 6224 Support Question

Find answers below for this question about Dell PowerConnect 6224.
Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by shAndr on June 17th, 2014

How To Set Clock On Dell Powerconnect 6224

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6224 Manual Pages

User's Guide - Page 19

...; 1U form factor, rack-mountable chassis design. • Support for all features, see the software version release notes. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for RJ-45 or SFP interfaces. The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for RJ-45 or SFP interfaces.
User's Guide - Page 74

... Configuring Dell PowerConnect General Configuration Information The PowerConnect 6200 Series switches are used to define the relationship of the switch to match the speed of the switch. Terminal Connection Configuration Your switch requires...(config)#line console console(config-line)#speed 115200 NOTE: Remember to set the baud rate on the terminal emulator software on your workstation to...
User's Guide - Page 81

... use the local authentication setting only. Configuring Dell PowerConnect 81 To save the configuration, enter: console#copy running-config startup-config Easy Setup Wizard An Easy Setup Wizard displays when the system boots up the IP address for the autoconfig feature? You may enter the system to make the switch manageable. Configuration Overview Before...
User's Guide - Page 82

... allowed in the field without a serial connection, the switch waits 60 seconds for you to respond to a set -up wizard continues to display each time you login until you return to configure security access for SNMPv3 (for the Easy Setup Wizard. 82 Configuring Dell PowerConnectSets up the SNMP community string to be powered...
User's Guide - Page 84

...setup wizard within 60 seconds)? [Y/N] y Step 1: 84 Configuring Dell PowerConnect The values used is provided in parentheses. You can skip the...by entering [ctrl+z]. Waiting to manually configure the switch. You may also choose to allow all IP...for the default management VLAN (1). • A default gateway address is set up as defined above . Note: You can access the SNMP, HTTP...
User's Guide - Page 85

... account: Please enter the user name: admin Please enter the user password: ******** Please reenter the user password: ******** Step 3: Configuring Dell PowerConnect 85 The wizard automatically assigns the highest access level [Privilege Level 15] to this setting, and to change privilege levels later. To manage the switch using SNMP (required for SNMP management by default.
User's Guide - Page 86

...255.255.255.0 Step 4: Finally, set up configuration file. To setup an ...Dell PowerConnect You will now enter CLI mode. ..... If the information is defined on the network). The IP address is incorrect, select (N) to discard configuration and restart the wizard: [Y/N] y Thank you use to the start-up the gateway. This is setup. Next, an IP address is the IP address you for the switch...
User's Guide - Page 88

... HTTP Password • Configuring an Initial HTTPS Password Modifying Switching Port Default Settings When configuring/receiving IP addresses through DHCP and BOOTP, the configuration received from these servers includes the IP address, and may include subnet mask and default gateway. 88 Configuring Dell PowerConnect command when specified on an empty line provides the list...
User's Guide - Page 89

... Enabled On (Enabled) On Off Configuring Dell PowerConnect 89 In this prompt indicates that the host name is currently in the interface configuration mode. indicates that the CLI is operating on a generic set of interfaces. • SwitchA(config-if-1/xg1)# - Table 5-1. Enter this by the PowerConnect 6200 Series switches: • SwitchA> - To go to an...
User's Guide - Page 91

...set to enable access and configuration rights to the switch from the Boot menu. The system is lost, a password recovery procedure can be invoked from the local terminal with no password entered. Configuring Dell PowerConnect... for the local terminal only and allows a one-time access to the switch. Data encryption is handled through the SSH mechanism. Interface IP Address IP ...
User's Guide - Page 95

... that appears: console#copy tftp://10.254.24.64/pc62xxr0v34.stk image Mode TFTP Set TFTP Server IP 10.254.24.64 TFTP Path TFTP Filename PC6224v3.2.1.0.stk Data Type...to start? (y/n) y Configuring Dell PowerConnect 95 When the new image is downloaded, it is saved in the area allocated for the duration of the transfer Are you sure you want to the switch. The following is an ...
User's Guide - Page 105

... COM port. This section does not explain the various configurations available on the switch or the relevant commands. If a previously entered configuration causes problems, the startup-configuration file - Configuring Dell PowerConnect 105 See "Device Default Settings." This section also describes accessing a switch for the first time with the following components are required for example...
User's Guide - Page 111

... console) that the interface status changed to "up" and that the STP status is set with the default settings. Connect the management station to the switch through one of the Ethernet ports, or through a network connected to continue? (y/n) y...01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding Configuring Dell PowerConnect 111 This example uses port 1/xg1. 3. Once device reloads -
User's Guide - Page 112

... access for a remote user (HTTP and HTTPS). Use the following command to set the IP address to DHCP and return to be in STP forwarding mode before ...ip https authentication local 112 Configuring Dell PowerConnect time=0 ms 64 bytes from 50.1.1.2: icmp_seq=1. console>ping 50.1.1.2 64 bytes from 50.1.1.2: icmp_seq=2. time=0 ms 64 bytes from the switch to the interface, configure a ...
Getting Started Guide - Page 7

...the latest updates on documentation and firmware. The ambient switch operating temperature range is 0 to 45ºC (32 to 113ºF) at support.dell.com for operator access. There is routed to ...; One PowerConnect switch • One AC power cable • One RS-232 cable • One rack-mount kit for rack installation (two mounting brackets, bolts, and cage nuts) • One set of self...
Getting Started Guide - Page 14

... is not configured with a valid password. The wizard sets up the following assumptions: • The PowerConnect switch was never configured before and is in the same state as when you received it. • The PowerConnect switch booted successfully. • The console connection was established and the Dell Easy Setup Wizard prompt appears on the screen of...
Release Notes - Page 1

... in any proprietary interest in trademarks and trade names other than its own. All rights reserved. Microsoft and Windows are trademarks of Dell Inc; DellPowerConnect6224/6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmware Version 3.2.0.6 Information in this document is subject to change without...
Release Notes - Page 3

...installing or upgrading of firmware be thoroughly reviewed prior to this product. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. You MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your...
Release Notes - Page 25

...set the number of seconds that session. Use 'no banner motd acknowledge Description Controls (enables or disables) the display of message-of-the-day banners. 'banner motd' enables the banner, and allows configuration of the command to the DellPowerConnect...supported. Default: The switch remains in the quiet state for details. PowerConnect 6224/6224F/6224P/6248/6248P Release ...
Configuration Guide - Page 9

...basic system and port settings, use system interfaces and utilities, and create and use CLI scripts. • "Switching Configuration" on page 29 provides configuration scenarios for layer 2 switching, including creating virtual ...PIM) on the switch. • "Utility" on page 149 describes how to use the DellPowerConnect™ 6200 Series switch in a typical network. 1 About this Document ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6224 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls