Dell PowerConnect 5324 Support Question
Find answers below for this question about Dell PowerConnect 5324.Need a Dell PowerConnect 5324 manual? We have 4 online manuals for this item!
Question posted by jadwel on December 8th, 2013
How Would I Create Vlans On A Powerconnect 5324
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 5324 Manual Pages
Command Line Interface Guide - Page 324
.... console> show system System Description: System Up Time (days,hour:min:sec): System Contact: System Name: System location: System MAC Address: Sys Object ID: Type: PowerConnect 5324
Corporate 1,22:38:21
RS1
00:10:B5:F4:00:01
Power Supply -----------Main Secondary
Status OK OK
Fan -----------1 2
Status OK OK
show version
The...
Release Notes - Page 1
... registered trademarks of Dell Inc is strictly forbidden Trademarks used in this document is prohibited, except as allowed under the copyright laws. Dell™ PowerConnect™ 5324
PowerConnect 5324 Release Notes
Date: October 2006 System Firmware Version 2.0.0.39
Information in this document to refer to change without the written permission of Microsoft Corporation. Reproduction...
Release Notes - Page 5
... Guide.
GLOBAL SUPPORT
By Web: http://support.dell.com/ For information regarding the functionalities listed, please refer to the PowerConnect 5324 Getting Started Guide for the Dell PowerConnect 5324 Switch system, firmware version 2.0.0.39. The boot prom image should be thoroughly reviewed prior to installing or upgrading of this release
NOTE: When the new firmware...
Release Notes - Page 6
...values too.
24400 25085
Description
When connected to a PowerConnect 5324 and the user connects to another switch ("second switch") using the "Telnet" command, a fatal error message... Configuring Multiple Spanning Tree • Configuring QinQ • Configuring Load Balancing
PowerConnect 5324 Release Notes
Issues resolved
None
Known Restrictions and Limitations
Web-based Management
Title ...
Release Notes - Page 7
PowerConnect 5324 Release Notes
Security
SSH
Title Serial connection is lost after 4 concurrent...not use VLAN 0 for "Authenticated Users" status.
25857
System Firmware Version 2.0.0.39
Subject to become inactive. Once a key is 1. Workaround: Do not open a forth SSH session will cause the serial connection to the device to Change Without Notice
Page 3
Switch default VLAN is ...
Release Notes - Page 8
ID 23043
System Firmware Version 2.0.0.39
Subject to Change Without Notice
Page 4
Configuration
Ping
Title Ping packets sent from a network using a 10Mbps hub are lost
PowerConnect 5324 Release Notes
Description
Ping packets that are sent from network using a 10Mbps hub are lost.
Release Notes - Page 9
System Firmware Version 2.0.0.39
Subject to Change Without Notice
Page 5 Flow Control
PowerConnect 5324 Release Notes
Note: When Flow Control is disabled per interface, flow control will be disabled per device not per Interface.
Release Notes - Page 10
... the operation, the terminal was replaced by another one or the speed mode was switched over on an Inband Interface
Modify the following:
Current
Console (config-if) # ... automatic baud detection, press the Enter key twice.
PowerConnect 5324 Release Notes
Documentation updates
Introduction
This document lists the changes from the PowerConnect 5324 User's Guide. Note: In the Web browser enable...
Release Notes - Page 11
.... LAG Configuration
Defining LAG Parameters
Add to the description: The LACP port channel can also be active at the same time. The range is zero.
PowerConnect 5324 Release Notes
Defining a New Community
Add extra instructions. The new community is saved, and the device is displayed. 7 Click Refresh. The SNMP Community page...
Release Notes - Page 12
... The Utilization Summary page contains statistics for viewing interface utilization.
GVRP Statistics
Field
Current
Leave All
Device GVRP Leave all dynamic VLANs participating in forwarded. Port Mirroring
PowerConnect 5324 Release Notes
Defining Port Mirroring Sessions
Add the following restriction: A maximum of 8 ports can be monitored (both currently configured (initial number...
Release Notes - Page 13
... 3 - 4 → WRR mode can be configured on queues 1 - 2 and SP on queues 3 - 4 → WRR mode can be configured on all queues 1 - 4.
Interface CoS/QoS Settings
PowerConnect 5324 Release Notes
The following Screens has been updated under the QOS section
Remove the following instructions:
Displaying QoS/CoS settings:
1.
The Interface Table is Strict...
Release Notes - Page 14
... range 1-255. The percentage translation of WRR Bandwidth - Specifies if traffic scheduling is enabled only for queues in the WRR Weight field. Global Queue Settings
PowerConnect 5324 Release Notes
The following Screens has been updated under the QOS section
Add the following field descriptions below the current descriptions:
• WRR -
Release Notes - Page 16
... device is reset. Up to enable port security, the Multiple Hosts feature must first be one of the following values: login, 802.1x or all .
PowerConnect 5324 Release Notes
unlearned source.
Specifies the server usage type. New
Usage Type - This is disabled"
Note: In order to 4 RADIUS servers can be one of...
Release Notes - Page 21
... guidelines for this command. channel-group
PowerConnect 5324 Release Notes
Update the command as expedite queues.
Change to
add.
wrr-queue bandwidth
Update the command as follows:
Field User Guidelines
Current Guide
♦ All 4 queues are participating excluding the queues that are serviced. switchport trunk allowed vlan
Update the command as follows:
Field...
Release Notes - Page 22
...
Page 18 System Firmware Version 2.0.0.39
Subject to enable the SNTP client on a specific interface.
PowerConnect 5324 Release Notes
• remove vlan-list-List of VLAN IDs to
VLAN IDs with a comma and no
remove.
The option all
removes all configured VLAN IDs. Change to: The system supports up to enable the SNTP client on a specific...
Release Notes - Page 23
... following commands are documented but not supported in this release.
• default vlan-disable • show vlan internal usage • ip internal-usage-vlan
Modified Text
Under the heading Editing Features and sub-heading Terminal Command Buffer. Example. radius-server host
PowerConnect 5324 Release Notes
Change a parameter description:
Syntax Parameter
User Guidelines
Current Guide...
User's Guide - Page 21
The MAC addresses are stored in the Bridging Table. For more information on configuring the MAC Address Age Out Time, see "Multicast Forwarding Support". VLAN-aware MAC-based Switching Packets arriving from overflowing. For more efficiently forwarded using the Hardware Table. From the frame, the device identifies work stations to an upstream Multicast...
User's Guide - Page 22
... forwarded by forwarding copies of incoming and outgoing packets from a monitored port to a VLAN based on either the VLAN tag or based on the relevant VLAN.
For more information, see "Enabling Storm Control".
Users specify which target port receives copies of switching ports that comprise a single broadcast domain. This occupies bandwidth, and loads all...
User's Guide - Page 215
...The port operational status.
The port is currently disabled, and is used ensure that when a hub or switch is disabled on the port. The configured rate for end stations. The port type determines ... disables flow control or enables the auto negotiation of flow control on the port.
When two hubs/switches are connected to each other , or two end stations are :
Suspended - The possible field...
User's Guide - Page 255
... 256 VLANs. VLAN Name - The VLAN was dynamically created through GVRP. Static - The device supports the mapping of 4094 VLAN IDs to VLAN ID or VLAN name. VLAN Membership Page
Show VLAN - Status - The VLAN type. Possible values are:
Dynamic - Enables or disables unauthorized users from the system. To open the VLAN Membership page, click Switch→VLAN→VLAN Membership...
Similar Questions
How To Factory Default A Dell Powerconnect 5324
(Posted by Cocoolpi 9 years ago)
How To Reset Powerconnect 5324 On Manual Button
(Posted by SandhO 10 years ago)
Dell Powerconnect 5324 Restore Can Not Enable
(Posted by clayafin 10 years ago)