User Guide
Page 3
... 2 Hardware Description and Connection 9 2.1 Rear Panel ...9 2.1.1 Rear Panel Power Connection 9 2.2 Front Panel ...9 2.2.1 RJ-45 Auto-negotiating Ports 10 2.2.2 IEEE 802.3az EEE ...10 2.2.3 SFP Slots (GS1100-24 Only 10 2.2.4 Front Panel Connections ...12 2.2.5 Front Panel LEDs ...12 2.3 Hardware Installation ...14 2.3.1 Wall Mounting ...14 2.3.2 Rack Mounting ...15 2.3.3 Mounting the Switch on a Rack...
... 2 Hardware Description and Connection 9 2.1 Rear Panel ...9 2.1.1 Rear Panel Power Connection 9 2.2 Front Panel ...9 2.2.1 RJ-45 Auto-negotiating Ports 10 2.2.2 IEEE 802.3az EEE ...10 2.2.3 SFP Slots (GS1100-24 Only 10 2.2.4 Front Panel Connections ...12 2.2.5 Front Panel LEDs ...12 2.3 Hardware Installation ...14 2.3.1 Wall Mounting ...14 2.3.2 Rack Mounting ...15 2.3.3 Mounting the Switch on a Rack...
User Guide
Page 5
... DETAILS GS1100-8HP GS1100-16 8 10/100/1000Base-T Ethernet ports (including 4 PoE ports) 16 10/100/1000Base-T Ethernet ports 24 10/100/1000Base-T Ethernet ports 2 100/1000Base-X SFP slots One physical IEEE 802.3az ON/OFF button One power ON/OFF switch GS1100-24 GS1100-24E The GS1100-8HP ...Guide 5 It can be used to build highperformance switched workgroup networks. This User's Guide covers the following models: GS1100-8HP, GS1100-16, GS1100-24, and GS110024E. The Switch is fanless and designed for workgroups, departments or backbone computing environments for uplink connection...
... DETAILS GS1100-8HP GS1100-16 8 10/100/1000Base-T Ethernet ports (including 4 PoE ports) 16 10/100/1000Base-T Ethernet ports 24 10/100/1000Base-T Ethernet ports 2 100/1000Base-X SFP slots One physical IEEE 802.3az ON/OFF button One power ON/OFF switch GS1100-24 GS1100-24E The GS1100-8HP ...Guide 5 It can be used to build highperformance switched workgroup networks. This User's Guide covers the following models: GS1100-8HP, GS1100-16, GS1100-24, and GS110024E. The Switch is fanless and designed for workgroups, departments or backbone computing environments for uplink connection...
User Guide
Page 6
...Supports automatic address learning. • Supports IEEE 802.3az EEE • Supports IEEE 802.3af and IEEE 802.3at PoE standards (only GS1100-8HP) • Full wire speed forwarding rate. • Supports 802.1p CoS. • Embedded 8K MAC address table providing 8000 MAC...1.3 Applications This section provides two network topology examples in which the Switch is used. 6 GS1100 Series User's Guide Chapter 1 Getting to Know Your Switch Figure 1 Front Panel GS1100-8HP GS1100-16 GS1100-24 GS1100-24E 1.2 Features The following are the essential features of the Switch. • Conforms to IEEE...
...Supports automatic address learning. • Supports IEEE 802.3az EEE • Supports IEEE 802.3af and IEEE 802.3at PoE standards (only GS1100-8HP) • Full wire speed forwarding rate. • Supports 802.1p CoS. • Embedded 8K MAC address table providing 8000 MAC...1.3 Applications This section provides two network topology examples in which the Switch is used. 6 GS1100 Series User's Guide Chapter 1 Getting to Know Your Switch Figure 1 Front Panel GS1100-8HP GS1100-16 GS1100-24 GS1100-24E 1.2 Features The following are the essential features of the Switch. • Conforms to IEEE...
User Guide
Page 9
... supplied power cord or power adaptor to the power receptacle on or off. 2.2 Front Panel The front panel of the Switch. GS1100 Series User's Guide 9 For the GS1100-8HP, GS1100-16 and GS1100-24E, use the POWER ON/OFF switch to have the Switch power on the back of the Switch and the other end to...
... supplied power cord or power adaptor to the power receptacle on or off. 2.2 Front Panel The front panel of the Switch. GS1100 Series User's Guide 9 For the GS1100-8HP, GS1100-16 and GS1100-24E, use the POWER ON/OFF switch to have the Switch power on the back of the Switch and the other end to...
User Guide
Page 13
Off The Switch is receiving or transmitting data at 1000M speed. Blinking The port is not receiving power. GS1100 Series User's Guide 13 Off The port is below the power budget limit. PoE MAX Red On Power supplied to an ...Amber On Power is connected to the PoE port. Figure 11 Front Panel LEDs GS1100-8HP GS1100-16 GS1100-24 GS1100-24E Chapter 2 Hardware Description and Connection The following table describes the LEDs. Table 3 The Front Panel LED Descriptions: GS1100-8HP LED COLOR STATUS DESCRIPTION PWR Green On The Switch is on the Switch....
Off The Switch is receiving or transmitting data at 1000M speed. Blinking The port is not receiving power. GS1100 Series User's Guide 13 Off The port is below the power budget limit. PoE MAX Red On Power supplied to an ...Amber On Power is connected to the PoE port. Figure 11 Front Panel LEDs GS1100-8HP GS1100-16 GS1100-24 GS1100-24E Chapter 2 Hardware Description and Connection The following table describes the LEDs. Table 3 The Front Panel LED Descriptions: GS1100-8HP LED COLOR STATUS DESCRIPTION PWR Green On The Switch is on the Switch....
User Guide
Page 14
... page 15 for a comparison of the hardware installation methods of each GS1100 model: Table 5 GS1100 Series Installation Comparison Table MODEL FEATURE Desktop Device Wall-mountable Rack-mountable GS1100-8HP GS1100-16 GS1100-24 GS1100-24E Note: Ask an authorized technician to attach the Switch to a wall. 14 GS1100 Series User's Guide Chapter 2 Hardware Description and Connection Table 3 The Front...
... page 15 for a comparison of the hardware installation methods of each GS1100 model: Table 5 GS1100 Series Installation Comparison Table MODEL FEATURE Desktop Device Wall-mountable Rack-mountable GS1100-8HP GS1100-16 GS1100-24 GS1100-24E Note: Ask an authorized technician to attach the Switch to a wall. 14 GS1100 Series User's Guide Chapter 2 Hardware Description and Connection Table 3 The Front...
User Guide
Page 15
... gap must be big enough for the screw heads to slide into the wall (see the figure in a wiring closet with other equipment. GS1100 Series User's Guide 15 leave a small gap between the centers of the Switch. The Switch should not be facing up or down the back.... Use screws with your Switch on a standard EIA rack using a rackmounting kit. Hang the Switch on page 15 for wall mounting MODEL GS1100-8HP GS1100-16 DISTANCE 120 mm 148 mm GS1100-24E 207 mm 1 Screw the two screws provided with 6 mm ~ 8 mm (0.24" ~ 0.31") wide heads. Rack-mounted Installation Requirements • ...
... gap must be big enough for the screw heads to slide into the wall (see the figure in a wiring closet with other equipment. GS1100 Series User's Guide 15 leave a small gap between the centers of the Switch. The Switch should not be facing up or down the back.... Use screws with your Switch on a standard EIA rack using a rackmounting kit. Hang the Switch on page 15 for wall mounting MODEL GS1100-8HP GS1100-16 DISTANCE 120 mm 148 mm GS1100-24E 207 mm 1 Screw the two screws provided with 6 mm ~ 8 mm (0.24" ~ 0.31") wide heads. Rack-mounted Installation Requirements • ...
User Guide
Page 16
Figure 12 Attaching the Mounting Brackets (GS1100-16 and GS1100-24E) Figure 13 Attaching the Mounting Brackets (GS1100-24) 2 Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting bracket holes into the Switch. 3 Repeat steps 1 and 2 to anchor the rack ...
Figure 12 Attaching the Mounting Brackets (GS1100-16 and GS1100-24E) Figure 13 Attaching the Mounting Brackets (GS1100-24) 2 Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting bracket holes into the Switch. 3 Repeat steps 1 and 2 to anchor the rack ...
User Guide
Page 17
GS1100 Series User's Guide 17 Chapter 2 Hardware Description and Connection Figure 14 Mounting the Switch on a Rack (GS1100-16 and GS1100-24E) Figure 15 Mounting the Switch on a Rack (GS1100-24) 2 Using a #2 Philips screwdriver, install the M5 flat head screws through the mounting bracket holes into the rack. 3 Repeat steps 1 and 2 to attach the second mounting bracket on the other side of the rack.
GS1100 Series User's Guide 17 Chapter 2 Hardware Description and Connection Figure 14 Mounting the Switch on a Rack (GS1100-16 and GS1100-24E) Figure 15 Mounting the Switch on a Rack (GS1100-24) 2 Using a #2 Philips screwdriver, install the M5 flat head screws through the mounting bracket holes into the rack. 3 Repeat steps 1 and 2 to attach the second mounting bracket on the other side of the rack.
User Guide
Page 20
...path loop forms when there is a common cause of network collision or other network problems that will severely affect your network topology. 20 GS1100 Series User's Guide Too many hubs between the computers in the network A loop in the data path The network cables should not ...Replace with new standard network cables. Non-standard cables may be longer than are no loops in your network performance. Figure 16 Troubleshooting Improper Network Cabling and Topology PROBLEM Faulty cables Non-standard network cables Cabling Length CORRECTIVE ACTION Using faulty network cables may ...
...path loop forms when there is a common cause of network collision or other network problems that will severely affect your network topology. 20 GS1100 Series User's Guide Too many hubs between the computers in the network A loop in the data path The network cables should not ...Replace with new standard network cables. Non-standard cables may be longer than are no loops in your network performance. Figure 16 Troubleshooting Improper Network Cabling and Topology PROBLEM Faulty cables Non-standard network cables Cabling Length CORRECTIVE ACTION Using faulty network cables may ...
User Guide
Page 23
... 21 D Data path loop 20 disclaimer 21 E EEE 5, 10 Energy Efficient Ethernet 10 F Faulty cables 20 FCC interference statement 21 Front Panel 9 GS1100 Series User's Guide Index Index Front Panel Connections 12 H High Power over Ethernet 8 I IEEE 802.3at 8 IEEE 802.3az 10 installation precautions... 16 transceivers 10 L LED Descriptions LK/ACT 14 PWR 13, 14 Low Power Idle 10 LPI signal 10 M mounting brackets 16 N network cable crossover 12 straight-through 12 Network Cable Types 12 Non-standard network cables 20...
... 21 D Data path loop 20 disclaimer 21 E EEE 5, 10 Energy Efficient Ethernet 10 F Faulty cables 20 FCC interference statement 21 Front Panel 9 GS1100 Series User's Guide Index Index Front Panel Connections 12 H High Power over Ethernet 8 I IEEE 802.3at 8 IEEE 802.3az 10 installation precautions... 16 transceivers 10 L LED Descriptions LK/ACT 14 PWR 13, 14 Low Power Idle 10 LPI signal 10 M mounting brackets 16 N network cable crossover 12 straight-through 12 Network Cable Types 12 Non-standard network cables 20...