Page 3
...terminals or open-end spade terminals with 25" (63.5 cm) countertop; Product Dimensions A F B* Location Requirements IMPORTANT: Observe all electrical connections should be rated at back of range** F. 23³⁄₄" (60.3 cm) countertop notch to terminal block) ■ 3 - Model/serial number plate ...to the standards listed above the surface units should be located for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with ranges. Check existing electrical supply. This oven has been designed in * C. The model/serial rating plate is installed in a mobile home, ...
...terminals or open-end spade terminals with 25" (63.5 cm) countertop; Product Dimensions A F B* Location Requirements IMPORTANT: Observe all electrical connections should be rated at back of range** F. 23³⁄₄" (60.3 cm) countertop notch to terminal block) ■ 3 - Model/serial number plate ...to the standards listed above the surface units should be located for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with ranges. Check existing electrical supply. This oven has been designed in * C. The model/serial rating plate is installed in a mobile home, ...
Installation Instructions
Page 4
... the green ground wire of the 4-wire power supply cord is recommended that a qualified electrical installer determine that the electrical connection and wire size are in the "Product Dimensions" section of the range. ■ The wiring diagram is located behind the storage drawer panel. mobile homes; When...91.4 cm) of slack in the line so that specify use an extension cord. Nothing located in a clear plastic bag. Electrical Connection To properly install your range, you must conform with kit. Range Rating* 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW 120/208 Volts 7.8 - 12.5 KW 12...
... the green ground wire of the 4-wire power supply cord is recommended that a qualified electrical installer determine that the electrical connection and wire size are in the "Product Dimensions" section of the range. ■ The wiring diagram is located behind the storage drawer panel. mobile homes; When...91.4 cm) of slack in the line so that specify use an extension cord. Nothing located in a clear plastic bag. Electrical Connection To properly install your range, you must conform with kit. Range Rating* 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW 120/208 Volts 7.8 - 12.5 KW 12...
Installation Instructions
Page 5
...sure the wall receptacle is properly grounded. Tile countertops may permit the use a 50-amp rated cord with local codes. Electrical Shock Hazard Electrically ground range. A copy of range's final location. ■ Do not use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening... corner of NEMA Type 10-50R. 3-wire receptacle (10-50R) Electrical Requirements - If countertop is recommended that a qualified electrical installer determine that the electrical connection and wire size are in range fit over the cutout edge of Power Supply Cord Kit and Circuit ...
...sure the wall receptacle is properly grounded. Tile countertops may permit the use a 50-amp rated cord with local codes. Electrical Shock Hazard Electrically ground range. A copy of range's final location. ■ Do not use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening... corner of NEMA Type 10-50R. 3-wire receptacle (10-50R) Electrical Requirements - If countertop is recommended that a qualified electrical installer determine that the electrical connection and wire size are in range fit over the cutout edge of Power Supply Cord Kit and Circuit ...
Installation Instructions
Page 7
... Hazard Disconnect power before servicing. Remove plastic tag holding three 10-32 hex nuts from the middle post of the range. Failure to the bracket holes of the determined mounting method. U.S.A. Electrically ground range. Floor Mounting Wall Mounting A B A B A. #12 x 1⁵⁄₈" screws B. Pull cover down and toward you to the wall or...
... Hazard Disconnect power before servicing. Remove plastic tag holding three 10-32 hex nuts from the middle post of the range. Failure to the bracket holes of the determined mounting method. U.S.A. Electrically ground range. Floor Mounting Wall Mounting A B A B A. #12 x 1⁵⁄₈" screws B. Pull cover down and toward you to the wall or...
Installation Instructions
Page 9
... green ground wire from the back of the range. Removable retaining nut B. Cord/conduit plate D. The ground wire must be attached first. 9 A 4-wire connection: Power Supply Cord Use this method for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you...
... green ground wire from the back of the range. Removable retaining nut B. Cord/conduit plate D. The ground wire must be attached first. 9 A 4-wire connection: Power Supply Cord Use this method for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you...
Installation Instructions
Page 10
... with nominal 1³⁄₈" (3.5 cm) diameter connection opening , with ring terminals and marked for use with one of range. Strip outer covering back 3" (7.6 cm) to the terminal block. Complete electrical connection according to the outer terminal block posts with 10-32 hex nuts. 4. A F A E B C E D...Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method only if local codes permit connecting chassis ground ...
... with nominal 1³⁄₈" (3.5 cm) diameter connection opening , with ring terminals and marked for use with one of range. Strip outer covering back 3" (7.6 cm) to the terminal block. Complete electrical connection according to the outer terminal block posts with 10-32 hex nuts. 4. A F A E B C E D...Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method only if local codes permit connecting chassis ground ...
Installation Instructions
Page 13
...an extra part, go back through the steps to floor or wall. ■ Slide range back so rear range foot is plugged into appropriate outlet. For direct-wired ranges: WARNING Electrical Shock Hazard Disconnect power before operating. Replace all packaging materials. 4. Disconnect power. 2. ...to avoid damaging the floor covering. Complete cleaning or maintenance. 4. When moving range, slide range onto cardboard or hardboard to children and adults. Plug power cord into an outlet. ■ Electrical supply is under anti-tip bracket. 6. Check that you have all parts...
...an extra part, go back through the steps to floor or wall. ■ Slide range back so rear range foot is plugged into appropriate outlet. For direct-wired ranges: WARNING Electrical Shock Hazard Disconnect power before operating. Replace all packaging materials. 4. Disconnect power. 2. ...to avoid damaging the floor covering. Complete cleaning or maintenance. 4. When moving range, slide range onto cardboard or hardboard to children and adults. Plug power cord into an outlet. ■ Electrical supply is under anti-tip bracket. 6. Check that you have all parts...