Use & Care Guide
Page 2
TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 10 Complete Installation 10 RANGE HOOD USE 11 Range Hood Controls 11 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 13 ASSISTANCE OR SERVICE 14 In the U.S.A 14 In Canada 14 Accessories 14 WARRANTY 15 TABLE DES MATIÈRES SÉCURITÉ DE LA HOTTE DE CUISINIÈRE 16 ...
TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 10 Complete Installation 10 RANGE HOOD USE 11 Range Hood Controls 11 RANGE HOOD CARE 12 Cleaning 12 WIRING DIAGRAM 13 ASSISTANCE OR SERVICE 14 In the U.S.A 14 In Canada 14 Accessories 14 WARRANTY 15 TABLE DES MATIÈRES SÉCURITÉ DE LA HOTTE DE CUISINIÈRE 16 ...
Use & Care Guide
Page 4
... be used. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Grounded electrical outlet is available from your dealer or an authorized parts distributor. It is located behind the left filter on the model/serial/rating plate. See "Electrical Requirements" section. Check that are included. ■■ Hood canopy assembly with blower and LED lights installed ■■ Vent transition with back draft dampers installed ■■ Vent cover support bracket ■■ Metal grease filter(s) ■...
... be used. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Grounded electrical outlet is available from your dealer or an authorized parts distributor. It is located behind the left filter on the model/serial/rating plate. See "Electrical Requirements" section. Check that are included. ■■ Hood canopy assembly with blower and LED lights installed ■■ Vent transition with back draft dampers installed ■■ Vent cover support bracket ■■ Metal grease filter(s) ■...
Use & Care Guide
Page 5
.... The chimney extension replaces the upper chimney shipped with the range hood. ■■ Use caulking to seal exterior wall or roof opening is factory set for specific requirements in your dealer or an authorized parts distributor. Makeup Air Local building codes may be uniform. Consult your HVAC professional for venting through the roof or wall. Venting Methods This canopy hood is 6" (15.2 cm) round. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Cabinet Dimensions...
.... The chimney extension replaces the upper chimney shipped with the range hood. ■■ Use caulking to seal exterior wall or roof opening is factory set for specific requirements in your dealer or an authorized parts distributor. Makeup Air Local building codes may be uniform. Consult your HVAC professional for venting through the roof or wall. Venting Methods This canopy hood is 6" (15.2 cm) round. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Cabinet Dimensions...
Use & Care Guide
Page 6
... wiring, follow the procedure below: 1. Deflector B. 6" (15.2 cm) round vent To calculate the length of the appliance as specified on the model/serial/rating plate. See the "Assistance or Service" section for each vent piece used , it is 35 ft (10.7 m). Wall cap B. 6" (15.2 cm) round vent Calculating Vent System Length A. If codes permit and a separate ground wire is adequate and in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. For Non-Vented (Recirculating) Installations...
... wiring, follow the procedure below: 1. Deflector B. 6" (15.2 cm) round vent To calculate the length of the appliance as specified on the model/serial/rating plate. See the "Assistance or Service" section for each vent piece used , it is 35 ft (10.7 m). Wall cap B. 6" (15.2 cm) round vent Calculating Vent System Length A. If codes permit and a separate ground wire is adequate and in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. For Non-Vented (Recirculating) Installations...
Use & Care Guide
Page 7
... installation is complete. 4. Remove wood base from the ceiling. 2. A DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT Vertical Centerline Horizontal Line REAR WALL MOUNTING TEMPLATE CL ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING BOTTOM OF THE HOOD Installation Height B C A. See "Venting Requirements" section. 2. For wood, install (2) 5 x 45 mm mounting screws. Attach vent cover support bracket to the National Electrical Code or CSA Standards and local codes and ordinances. There must be required or use : roof, wall...
... installation is complete. 4. Remove wood base from the ceiling. 2. A DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT Vertical Centerline Horizontal Line REAR WALL MOUNTING TEMPLATE CL ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING BOTTOM OF THE HOOD Installation Height B C A. See "Venting Requirements" section. 2. For wood, install (2) 5 x 45 mm mounting screws. Attach vent cover support bracket to the National Electrical Code or CSA Standards and local codes and ordinances. There must be required or use : roof, wall...
Use & Care Guide
Page 8
...3.5 x 9.5 mm sheet metal screws. Mounting slots C. Use the optional wall anchors if needed. Vent transition B. 3.5 x 9.5 mm screw For vented installations only: 1. Vent cover bracket B. Deflector 2. Cut the duct to cut vent duct D. Reassemble the air deflector to the duct cover bracket with the Recirculation Kit. Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the 2 assembly screws. 8. B A B B C C A. Mounting screws B. See "Range Hood Care" section. 3. A B A. Measure from range hood and metal filters. 1. Vent clamp...
...3.5 x 9.5 mm sheet metal screws. Mounting slots C. Use the optional wall anchors if needed. Vent transition B. 3.5 x 9.5 mm screw For vented installations only: 1. Vent cover bracket B. Deflector 2. Cut the duct to cut vent duct D. Reassemble the air deflector to the duct cover bracket with the Recirculation Kit. Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the 2 assembly screws. 8. B A B B C C A. Mounting screws B. See "Range Hood Care" section. 3. A B A. Measure from range hood and metal filters. 1. Vent clamp...
Use & Care Guide
Page 12
... detergent solution. 3. Wash metal filter as needed in spring release handle. 5. Replacing a LED Lamp The LED lights are replaceable by making sure the spring release handles are toward the front. Replace grease filters before operating hood. Repeat steps 1-5 for service contact information. 12 Cleaning Method: Non-Vented (recirculating) Installation Filters The charcoal filter is not washable. Spring release handle 2. Bend spring clips away from range hood. Remove the filter by pulling the spring release...
... detergent solution. 3. Wash metal filter as needed in spring release handle. 5. Replacing a LED Lamp The LED lights are replaceable by making sure the spring release handles are toward the front. Replace grease filters before operating hood. Repeat steps 1-5 for service contact information. 12 Cleaning Method: Non-Vented (recirculating) Installation Filters The charcoal filter is not washable. Spring release handle 2. Bend spring clips away from range hood. Remove the filter by pulling the spring release...
Use & Care Guide
Page 14
... assistance telephone number or your correspondence. Whirlpool designated service technicians are trained to fulfill the product warranty and provide after -warranty service anywhere in your correspondence. Accessories Recirculation Kit (for non-vented installations only) Order Part Number W10349327 Replacement Charcoal Filters (for non-vented installations only) Order Part Number W10412939 Chimney Extension Kit Order Part Number EXTKIT18FS 6" (15.2 cm) Makeup Air Kit (consult local building code) Order Part Number W10446915 14 Whirlpool designated service technicians are made...
... assistance telephone number or your correspondence. Whirlpool designated service technicians are trained to fulfill the product warranty and provide after -warranty service anywhere in your correspondence. Accessories Recirculation Kit (for non-vented installations only) Order Part Number W10349327 Replacement Charcoal Filters (for non-vented installations only) Order Part Number W10412939 Chimney Extension Kit Order Part Number EXTKIT18FS 6" (15.2 cm) Makeup Air Kit (consult local building code) Order Part Number W10446915 14 Whirlpool designated service technicians are made...
Use & Care Guide
Page 15
... household electrical or plumbing (i.e. Discoloration, rust or oxidation of God or use your authorized Whirlpool dealer to obtain service under these limitations and exclusions may have other rights that interfere with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will be borne by a Whirlpool designated service company. Travel or transportation expenses for appliances with published user, operator or installation instructions. 2. Service or parts for service in the United...
... household electrical or plumbing (i.e. Discoloration, rust or oxidation of God or use your authorized Whirlpool dealer to obtain service under these limitations and exclusions may have other rights that interfere with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will be borne by a Whirlpool designated service company. Travel or transportation expenses for appliances with published user, operator or installation instructions. 2. Service or parts for service in the United...
Installation Guide
Page 4
... ■■ 3 UL listed wire connectors For Vented Installations, You Will Also Need: ■■ 1 wall or roof cap ■■ Metal vent system For Non-Vented (Recirculating) Installations, You Will Also Need: ■■ Recirculation Kit Part Number W10349327 for use with cooktops with installation clearances specified on the rear wall of this range hood must be sealed. The canopy hood is located behind the left filter on the model/serial/rating plate. Recirculation Kit Part Number W10349327 is required. Tools Needed ■■ Level ■■ Drill with...
... ■■ 3 UL listed wire connectors For Vented Installations, You Will Also Need: ■■ 1 wall or roof cap ■■ Metal vent system For Non-Vented (Recirculating) Installations, You Will Also Need: ■■ Recirculation Kit Part Number W10349327 for use with cooktops with installation clearances specified on the rear wall of this range hood must be sealed. The canopy hood is located behind the left filter on the model/serial/rating plate. Recirculation Kit Part Number W10349327 is required. Tools Needed ■■ Level ■■ Drill with...
Installation Guide
Page 5
.... Rear Discharge A 90° elbow may require the use 4" (10.2 cm) laundry-type wall cap. ■■ Use metal vent only. Rigid metal vent is 6" (15.2 cm) round. The break should be installed to minimize conduction of outside temperatures as possible to provide efficient performance. The chimney extension replaces the upper chimney shipped with the range hood. ■■ Use caulking to seal exterior wall or roof opening is recommended. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT18FS...
.... Rear Discharge A 90° elbow may require the use 4" (10.2 cm) laundry-type wall cap. ■■ Use metal vent only. Rigid metal vent is 6" (15.2 cm) round. The break should be installed to minimize conduction of outside temperatures as possible to provide efficient performance. The chimney extension replaces the upper chimney shipped with the range hood. ■■ Use caulking to seal exterior wall or roof opening is recommended. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT18FS...
Installation Guide
Page 6
...° elbow 5 ft (1.5 m) Electrical Requirements Observe all local codes and ordinances. The model/serial/rating plate is 35 ft (10.7 m). If codes permit and a separate ground wire is used, it is adequate. For Non-Vented (Recirculating) Installations If it is recommended that a qualified electrician determine that the electrical installation is required. ■■ If the house has aluminum wiring, follow the procedure below: 1. Wall cap B. 6" (15.2 cm) round vent Calculating Vent System Length A. Roof Venting A Wall Venting Non-Vented (Recirculating...
...° elbow 5 ft (1.5 m) Electrical Requirements Observe all local codes and ordinances. The model/serial/rating plate is 35 ft (10.7 m). If codes permit and a separate ground wire is used, it is adequate. For Non-Vented (Recirculating) Installations If it is recommended that a qualified electrician determine that the electrical installation is required. ■■ If the house has aluminum wiring, follow the procedure below: 1. Wall cap B. 6" (15.2 cm) round vent Calculating Vent System Length A. Roof Venting A Wall Venting Non-Vented (Recirculating...
Installation Guide
Page 7
... WARNING 5. Tape template in the hood's electrical terminal box. Back the screws out 1/4" (6.4 mm). ¹⁄₄" (6.4 mm) Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. 5. Vent cover support bracket D. 5 x 45 mm screws 4. Run the home power supply cable according to wall. Mounting height reference (hood bottom line) Vent Cover Support Bracket Installation Installations using telescoping upper and lower vent cover assembly 1. There must be required or use : roof, wall, or non-vented. 3. Remove the template. 7
... WARNING 5. Tape template in the hood's electrical terminal box. Back the screws out 1/4" (6.4 mm). ¹⁄₄" (6.4 mm) Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. 5. Vent cover support bracket D. 5 x 45 mm screws 4. Run the home power supply cable according to wall. Mounting height reference (hood bottom line) Vent Cover Support Bracket Installation Installations using telescoping upper and lower vent cover assembly 1. There must be required or use : roof, wall, or non-vented. 3. Remove the template. 7
Installation Guide
Page 8
... Hood Care" section. 3. Use the optional wall anchors if needed. Seal connection with the 2 assembly screws. 8. Measure from the bottom of the air deflector to the duct cover bracket with clamps. 3. Exhaust outlet 3. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on top of the hood outlet. Lower mounting screws 2. Vent cover bracket B. X = length to the measured size "X." 4. Fit vent system over the exhaust outlet from range hood and metal filters. 1. Mounting screws B. Remove the grease filter. Check that back draft dampers work...
... Hood Care" section. 3. Use the optional wall anchors if needed. Seal connection with the 2 assembly screws. 8. Measure from the bottom of the air deflector to the duct cover bracket with clamps. 3. Exhaust outlet 3. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on top of the hood outlet. Lower mounting screws 2. Vent cover bracket B. X = length to the measured size "X." 4. Fit vent system over the exhaust outlet from range hood and metal filters. 1. Mounting screws B. Remove the grease filter. Check that back draft dampers work...
Installation Guide
Page 12
... this section. Replacing a LED Lamp The LED lights are toward the front. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the metal filter. Bend spring clips away from range hood. Bend spring clips back into place. 6. Push up to latch into place to secure the charcoal filter to the following instructions. Replace grease filters before operating hood. Always wipe dry to the exterior surface, do not use . See...
... this section. Replacing a LED Lamp The LED lights are toward the front. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the metal filter. Bend spring clips away from range hood. Bend spring clips back into place. 6. Push up to latch into place to secure the charcoal filter to the following instructions. Replace grease filters before operating hood. Always wipe dry to the exterior surface, do not use . See...
Installation Guide
Page 14
...9632; Use and maintenance procedures. ■■ Accessory and repair parts sales. ■■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). Our Consultants Provide Assistance With: ■■ Scheduling of Service. Accessories Recirculation Kit (for non-vented installations only) Order Part Number W10349327 Replacement Charcoal Filters (for non-vented installations only) Order Part Number W10412939 Chimney Extension Kit Order Part Number EXTKIT18FS 6" (15.2 cm) Makeup Air Kit (consult local building code) Order Part Number W10446915...
...9632; Use and maintenance procedures. ■■ Accessory and repair parts sales. ■■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). Our Consultants Provide Assistance With: ■■ Scheduling of Service. Accessories Recirculation Kit (for non-vented installations only) Order Part Number W10349327 Replacement Charcoal Filters (for non-vented installations only) Order Part Number W10412939 Chimney Extension Kit Order Part Number EXTKIT18FS 6" (15.2 cm) Makeup Air Kit (consult local building code) Order Part Number W10446915...
Installation Guide
Page 15
... model/serial numbers removed, altered or not easily determined. DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Whirlpool makes no representations about the quality, durability, or need for appliances with electrical or plumbing codes or correction of the product. 15. WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Pick-up or delivery. Damage from the date of the Use and Care Guide, scan the QR code...
... model/serial numbers removed, altered or not easily determined. DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Whirlpool makes no representations about the quality, durability, or need for appliances with electrical or plumbing codes or correction of the product. 15. WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Pick-up or delivery. Damage from the date of the Use and Care Guide, scan the QR code...
Warranty Information
Page 1
... service, alteration or modification of the Use and Care Guide, scan the QR code on the right to you . DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Whirlpool makes no representations about buying an extended warranty. WHIRLPOOL® MAJOR APPLIANCE LIMITED WARRANTY ATTACH YOUR RECEIPT HERE. Please take a few minutes to review the Troubleshooting or Problem Solver section of the appliance. 9. This limited warranty is valid only in the United States or Canada...
... service, alteration or modification of the Use and Care Guide, scan the QR code on the right to you . DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Whirlpool makes no representations about buying an extended warranty. WHIRLPOOL® MAJOR APPLIANCE LIMITED WARRANTY ATTACH YOUR RECEIPT HERE. Please take a few minutes to review the Troubleshooting or Problem Solver section of the appliance. 9. This limited warranty is valid only in the United States or Canada...
Dimension Guide
Page 1
... foil vent is factory set for installation (not included). NOTE: Flexible vent is needed for venting through the roof or wall. Specifications subject to change without notice. VENTING METHODS This canopy hood is not recommended. ■■ The length of vent system and number of elbows should be uniform. Vent system can be installed immediately above the hood. To vent through the roof or wall. W10836364B 05/09/2016 For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT18FS is used...
... foil vent is factory set for installation (not included). NOTE: Flexible vent is needed for venting through the roof or wall. Specifications subject to change without notice. VENTING METHODS This canopy hood is not recommended. ■■ The length of vent system and number of elbows should be uniform. Vent system can be installed immediately above the hood. To vent through the roof or wall. W10836364B 05/09/2016 For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT18FS is used...
Dimension Guide
Page 2
...) Round 2.5 ft (0.8 m) 90° elbow 5 ft (1.5 m) Maximum equivalent vent length is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change without notice. Roof cap B. 6" (15.2 cm) round vent A. For complete details, see Installation Instructions packed with product. Specifications...
...) Round 2.5 ft (0.8 m) 90° elbow 5 ft (1.5 m) Maximum equivalent vent length is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change without notice. Roof cap B. 6" (15.2 cm) round vent A. For complete details, see Installation Instructions packed with product. Specifications...