Whirlpool WGD5620H Support and Manuals
Get Help and Manuals for this Whirlpool item
This item is in your list!
View All Support Options Below
Free Whirlpool WGD5620H manuals!
Problems with Whirlpool WGD5620H?
Ask a Question
Free Whirlpool WGD5620H manuals!
Problems with Whirlpool WGD5620H?
Ask a Question
Popular Whirlpool WGD5620H Manual Pages
Specification Sheet - Page 1
... money on your utility bills. Specifications subject to 150 minutes after the cycle ends or until you washed in the U.S.A. Front Load Gas Dryer
WGD5620H
White WGD5620HW
Key Features & Benefits
Wrinkle Shield™ Option Help keep wrinkles from setting into clean, dry fabrics with product.
For complete details, see Installation Instructions packed with the Wrinkle Shield™...
Installation Instructions - Page 5
... 20 A circuit for a gas dryer or 30 A circuit for an electric dryer.
■■ If using a power supply cord: Use a UL Listed power supply cord kit marked for your washer's water supply by purchasing the necessary parts noted in ring terminals or spade terminals with clothes dryers. Some codes limit, or do not permit, installing dryer in longer drying...
Installation Instructions - Page 6
... Part Number 346764 is suitable for wall, door, floor moldings, dryer venting, and gas line.
■■ Additional spacing should also be made in the same closet as a dryer. Space must not be considered on all sides of the door are required. Openings (such as dryer exhaust opening. Installation spacing for recessed area or closet installation All dimensions...
Installation Instructions - Page 8
... Power Supply Cord Replacement Part Number 8529008.
4-wire receptacle (14-30R)
For further information, please reference service numbers located in a risk of the equipment- A time-delay fuse or circuit breaker is recommended.
ELECTRIC DRYER POWER HOOKUP - CANADA ONLY
ELECTRICAL REQUIREMENTS
GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
It is your Use and Care Guide.
grounding...
Installation Instructions - Page 9
...NOTE: Pipe-joint compounds that an individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the dryer. A. 3/8" flexible gas connector B. 3/8" pipe to prevent kinking. Securely tighten all gas connections. Examples of Chemours.
9 Failure to the dryer. If this information does not agree with the National Fuel Gas Code, ANSI Z223.1. See illustration below.
■...
Installation Instructions - Page 17
... authorized service personnel. Connect gas supply to action of propane gas. Use pipe-joint compound on an approved noncorrosive leak-detection solution. A.
Non-flared male fitting
Remove red cap from gas pipe. Then, test all gas connections. Install a shut-off valve
1. Flared male fitting B. A recommended connection is shown. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe...
Installation Instructions - Page 23
....
Not Level
LEVEL
2. COMPLETE INSTALLATION CHECKLIST
Check that the flexible gas line is not level, prop up or down, and check again for leaks. Check to side. Gas Models: Plug into a grounded outlet. LEVEL DRYER
1. Repeat from side to be level for certain part replacement or repair.
Adjust leveling legs
Not Level...
Owners Manual 1 - Page 3
... installer, service agency, or the gas supplier.
3 Flexible venting materials are known to collapse, be performed by a qualified installer. − Install the clothes dryer according to follow all clothes dryers in the exhaust duct. Install all installation instructions. − Save these instructions.
WARNING FIRE HAZARD Failure to the manufacturer's instructions and local codes...
Owners Manual 1 - Page 8
... gun and compound (new vent installations)
Adjustable wrench that all models):
Pliers or slip-joint pliers
Tape measure
Utility knife
Tin snips (new vent installations)
Leveling legs (4) (Length and appearance of legs may be required, depending on your dryer.
Check local codes. Available Accessories:
Refer to the Quick Start Guide for service contact information.
For further...
Owners Manual 1 - Page 9
..., you will be made in the "Gas Dryer Power Hookup" section. � A sturdy floor to support dryer and a total weight (dryer and load) of installation and servicing, spacing for companion appliances, and clearances for ease of 200 lbs. (90.7 kg). Lower temperatures may cause dryer not to bottom of dryer. � Steam models only: Cold water faucets located within 2 ft...
Owners Manual 1 - Page 10
... appliance must have a proper outlet installed by UL for test gauge connection, immediately upstream of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. SAVE THESE INSTRUCTIONS
Explosion Hazard
Use a new CSA International approved gas supply line.
Gas Dryer Power Hookup - If this dryer be plugged into a grounded...
Owners Manual 1 - Page 12
... PTFE plumber's tape.
12 For mobile home use: Gas dryers must be securely fastened to supply line type, size, and location.
3. Connect gas supply to dryer
A. 3/8" (9.5 mm) flexible gas connector
B. 3/8" (9.5 mm) dryer pipe
C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to existing gas line. Bubbles will show a leak. Install a shut-off valve. Closed valve
B. Securely tighten all connections...
Owners Manual 1 - Page 13
... airflow and poor performance.
� Do not install in enclosed walls, ceilings, or floors.
� The total length should cap the vent to avoid sagging and kinking that may be used for best drying performance and to follow these instructions can be included in final dryer location.
� Remove excess to keep rodents...
Whirlpool WGD5620H Reviews
Do you have an experience with the Whirlpool WGD5620H that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Whirlpool yet.
Earn 750 points for your review!