Installation Guide
Page 4
... all installations: Flat-blade screwdriver #2 Phillips screwdriver 8" or 10" pipe wrench 8" or 10" adjustable wrench (for proper exhaust installation. Contact your dryer. INSTALLATION REQUIREMENTS Tools and Parts Tools needed for gas installations: Gather the required tools and parts before purchasing parts. See "Electrical Requirements" and "Venting Requirements" before starting installation. Check code...
... all installations: Flat-blade screwdriver #2 Phillips screwdriver 8" or 10" pipe wrench 8" or 10" adjustable wrench (for proper exhaust installation. Contact your dryer. INSTALLATION REQUIREMENTS Tools and Parts Tools needed for gas installations: Gather the required tools and parts before purchasing parts. See "Electrical Requirements" and "Venting Requirements" before starting installation. Check code...
Installation Guide
Page 5
...No other fuel-burning appliance can be exposed to water and/or weather. Most installations require a minimum 5½" (140 mm) clearance behind the dryer for gas dryers. ■■ If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side ...of 1" (25 mm) under entire dryer. See "Venting Requirements." 29" Wide Models Dryer Dimensions 29" (737 mm) 29" (737 mm) Installation Spacing 18"* (457 mm) 14...
...No other fuel-burning appliance can be exposed to water and/or weather. Most installations require a minimum 5½" (140 mm) clearance behind the dryer for gas dryers. ■■ If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side ...of 1" (25 mm) under entire dryer. See "Venting Requirements." 29" Wide Models Dryer Dimensions 29" (737 mm) 29" (737 mm) Installation Spacing 18"* (457 mm) 14...
Installation Guide
Page 7
...legs To avoid damaging floor, use Gas dryers must be securely fastened to match height of gas in the absence of cardboard from the gas specified on cardboard. 2. Gas type Natural gas: This dryer is equipped for use with the type of gas available, please reference the "Assistance ...Mobile Home Installation Hold-down on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. Firmly grasp dryer body (not console panel) and gently lay dryer down Kit. For ordering information, please reference the "Use and Care Guide." 7 capacity...
...legs To avoid damaging floor, use Gas dryers must be securely fastened to match height of gas in the absence of cardboard from the gas specified on cardboard. 2. Gas type Natural gas: This dryer is equipped for use with the type of gas available, please reference the "Assistance ...Mobile Home Installation Hold-down on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. Firmly grasp dryer body (not console panel) and gently lay dryer down Kit. For ordering information, please reference the "Use and Care Guide." 7 capacity...
Installation Guide
Page 8
... An individual manual shut-off valve must be easy to reach for opening and closing. E C A D ■■ If your gas dryer can use 3/8" approved tubing (if codes and gas supplier permit). ■■ If you are some guidelines for two different methods of connection...■■ The design of this elevation. rating indicated on the model/serial number plate is a registered trademark of your dryer to the gas supply line with a listed flexible gas connector that comes out through the rear of E.I. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■...
... An individual manual shut-off valve must be easy to reach for opening and closing. E C A D ■■ If your gas dryer can use 3/8" approved tubing (if codes and gas supplier permit). ■■ If you are some guidelines for two different methods of connection...■■ The design of this elevation. rating indicated on the model/serial number plate is a registered trademark of your dryer to the gas supply line with a listed flexible gas connector that comes out through the rear of E.I. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■...
Installation Guide
Page 9
... heavy metal exhaust vent and clamps may result in reduced airflow and poor performance. ■■ Do not install in a risk of fire, this dryer be grounded. Do not use an extension cord. grounding conductor can result in death, fire, or electrical shock. ■■ 120 Volt, 60...: If using an existing vent system, clean lint from entire length of the equipment- Only rigid or flexible metal vent shall be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of electric shock by a quali ed electrician. A time-delay fuse or ...
... heavy metal exhaust vent and clamps may result in reduced airflow and poor performance. ■■ Do not install in a risk of fire, this dryer be grounded. Do not use an extension cord. grounding conductor can result in death, fire, or electrical shock. ■■ 120 Volt, 60...: If using an existing vent system, clean lint from entire length of the equipment- Only rigid or flexible metal vent shall be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of electric shock by a quali ed electrician. A time-delay fuse or ...
Installation Guide
Page 12
...29" Wide Long Vent Models Only) Number of 90° turns or elbows Type of E.I. Connect vent to exhaust hood A B A. 3/8" flexible gas connector B. 3/8" dryer pipe C C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of vent to action of all connections by brushing on threads of ...LP gas. A recommended connection is used, be used to connect dryer to exhaust hood with 4" (102 mm) clamp. Secure vent to existing gas line. Avoid 90° turns. Then, test all non-flared male fittings...
...29" Wide Long Vent Models Only) Number of 90° turns or elbows Type of E.I. Connect vent to exhaust hood A B A. 3/8" flexible gas connector B. 3/8" dryer pipe C C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of vent to action of all connections by brushing on threads of ...LP gas. A recommended connection is used, be used to connect dryer to exhaust hood with 4" (102 mm) clamp. Secure vent to existing gas line. Avoid 90° turns. Then, test all non-flared male fittings...
Installation Guide
Page 13
... has not tripped. ■■ Dryer door is secured to exhaust hood with a damp cloth to see whether gas supply line shut-off valve is open. ■■ If the gas supply line shut-off valve is closed . If the dryer will go back through steps to remove... any tape remaining on a full heat cycle (not an air cycle) for levelness. After dryer is in dryer. If dryer is clean. q Check dryer's final location. q Wipe dryer drum interior thoroughly with ...
... has not tripped. ■■ Dryer door is secured to exhaust hood with a damp cloth to see whether gas supply line shut-off valve is open. ■■ If the gas supply line shut-off valve is closed . If the dryer will go back through steps to remove... any tape remaining on a full heat cycle (not an air cycle) for levelness. After dryer is in dryer. If dryer is clean. q Check dryer's final location. q Wipe dryer drum interior thoroughly with ...
Dimension Guide
Page 1
...) or 1½" (38 mm) (to match height of 3.8 cu. Recessed area B. Recessed area B. Gas Dryer PRODUCT MODEL NUMBERS WGD4800B, WGD4810B, WGD4850B, WGD4890B, WGD5500B, WGD5800B, WGD5810B 29" Wide Models Dryer Dimensions 29" (737 mm) 29" (737 mm) 27" Wide Models Dryer Dimensions 27" (686 mm) 433/8" (1102 mm) 433/8" (1102 mm) 43" (1092 mm) 1/2" (13...
...) or 1½" (38 mm) (to match height of 3.8 cu. Recessed area B. Recessed area B. Gas Dryer PRODUCT MODEL NUMBERS WGD4800B, WGD4810B, WGD4850B, WGD4890B, WGD5500B, WGD5800B, WGD5810B 29" Wide Models Dryer Dimensions 29" (737 mm) 29" (737 mm) 27" Wide Models Dryer Dimensions 27" (686 mm) 433/8" (1102 mm) 433/8" (1102 mm) 43" (1092 mm) 1/2" (13...
Dimension Guide
Page 2
...electrical supply is recommended to L.P. Installation clearances: The location must be used. INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is used it should be large enough to allow the dryer door to the action of the door are recommended. When rigid pipe is equipped for ...the exhaust vent with Natural gas. gas must be used for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is required. Most installations require a minimum 5½" (140 mm) ...
...electrical supply is recommended to L.P. Installation clearances: The location must be used. INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is used it should be large enough to allow the dryer door to the action of the door are recommended. When rigid pipe is equipped for ...the exhaust vent with Natural gas. gas must be used for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is required. Most installations require a minimum 5½" (140 mm) ...
Use & Care Guide
Page 10
... 4. If you will be on vacation or not using your dryer only when you should: 1. For gas dryers: 1. Replace the cover and secure with a 10-watt appliance bulb only. Unplug or disconnect power to secure dryer door. Changing the drum light (on the back wall of ...the cover. Close shutoff valve in death or electrical shock. Reinstalling the Dryer Follow the "Installation Instructions" to gas supply line. 3. Disconnect wiring. 3. Unplug dryer or disconnect power. 2. (For gas dryers only): Close shut off power at home. Remove the cover. Replace all parts and ...
... 4. If you will be on vacation or not using your dryer only when you should: 1. For gas dryers: 1. Replace the cover and secure with a 10-watt appliance bulb only. Unplug or disconnect power to secure dryer door. Changing the drum light (on the back wall of ...the cover. Close shutoff valve in death or electrical shock. Reinstalling the Dryer Follow the "Installation Instructions" to gas supply line. 3. Disconnect wiring. 3. Unplug dryer or disconnect power. 2. (For gas dryers only): Close shut off power at home. Remove the cover. Replace all parts and ...
Use & Care Guide
Page 11
...whirlpool.ca for the types of dryer cycles requires temperatures above 45ºF (7ºC). Use a time-delay fuse. The dryer may not have heat. Replace both fuses or reset the circuit breaker. Use 4" (102 mm) diameter vent material. Electric dryers use 2 household fuses or circuit breakers. Check with temperature below 45ºF (7ºC). The gas.... 11 Incorrect power supply. For gas dryers, make sure the supply line valve is open . Fabric softener sheets blocking the grill. Dryer located in a room with a qualified...
...whirlpool.ca for the types of dryer cycles requires temperatures above 45ºF (7ºC). Use a time-delay fuse. The dryer may not have heat. Replace both fuses or reset the circuit breaker. Use 4" (102 mm) diameter vent material. Electric dryers use 2 household fuses or circuit breakers. Check with temperature below 45ºF (7ºC). The gas.... 11 Incorrect power supply. For gas dryers, make sure the supply line valve is open . Fabric softener sheets blocking the grill. Dryer located in a room with a qualified...