Installation Guide
Page 3
... the cooktop base approved installation label for your builder or cabinet supplier to LP gas ■ Noncorrosive leak-detection solution Parts supplied ■ Gas pressure regulator ■ Burner grates ■ Burner caps ■ Burner base ■ Clamping brackets (2) ■ Bracket attachment screws (2) Parts needed Check local codes and consult gas supplier...
... the cooktop base approved installation label for your builder or cabinet supplier to LP gas ■ Noncorrosive leak-detection solution Parts supplied ■ Gas pressure regulator ■ Burner grates ■ Burner caps ■ Burner base ■ Clamping brackets (2) ■ Bracket attachment screws (2) Parts needed Check local codes and consult gas supplier...
Installation Guide
Page 5
... and electrical supply sources must be provided. ■ Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are provided with the regulator. Do not remove ground prong. See "Wiring Diagrams" on 36" models B. Combustible area above countertop (shown by not less than ¹⁄₄" [0.6 cm] flame...
... and electrical supply sources must be provided. ■ Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are provided with the regulator. Do not remove ground prong. See "Wiring Diagrams" on 36" models B. Combustible area above countertop (shown by not less than ¹⁄₄" [0.6 cm] flame...
Installation Guide
Page 6
... valve "open" position C. If converting to LP gas, see the "LP Gas Conversion" instructions provided in the same room but external to the cooktop pressure regulator. ■ Do not kink or damage the flexible metal tubing when moving the cooktop. Gas Supply Requirements WARNING Explosion Hazard Use a new CSA International approved...
... valve "open" position C. If converting to LP gas, see the "LP Gas Conversion" instructions provided in the same room but external to the cooktop pressure regulator. ■ Do not kink or damage the flexible metal tubing when moving the cooktop. Gas Supply Requirements WARNING Explosion Hazard Use a new CSA International approved...
Installation Guide
Page 7
...Maximum pressure: 14" (35.5 cm) WCP Contact local gas supplier if you are not sure about the inlet pressure. Gas Pressure Regulator The gas pressure regulator supplied with this cooktop must be isolated from the gas supply piping system during any pressure testing of that system at test pressures ...must be as follows for each 1,000 ft (304.8 m) above the manifold pressure shown on the model/serial rating plate are for testing regulator must be disconnected from the gas supply piping system by closing its individual shutoff valve must be at least 1" water column pressure above sea...
...Maximum pressure: 14" (35.5 cm) WCP Contact local gas supplier if you are not sure about the inlet pressure. Gas Pressure Regulator The gas pressure regulator supplied with this cooktop must be isolated from the gas supply piping system during any pressure testing of that system at test pressures ...must be as follows for each 1,000 ft (304.8 m) above the manifold pressure shown on the model/serial rating plate are for testing regulator must be disconnected from the gas supply piping system by closing its individual shutoff valve must be at least 1" water column pressure above sea...
Installation Guide
Page 9
...person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Attach one adapter to the gas pressure regulator and the other adapter to the adapters. Manifold entrance B. Manual gas shutoff valve I K A. Use pipe-joint compound....must have ½" male pipe thread) E. H. Flexible connector (pass through wall between cabinets) F. Typical flexible connection 1. Gas pressure regulator C. Use pipe-joint compound. Manifold entrance B. ³⁄₈" elbow C. Use a combination wrench and channel lock pliers to attach...
...person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Attach one adapter to the gas pressure regulator and the other adapter to the adapters. Manifold entrance B. Manual gas shutoff valve I K A. Use pipe-joint compound....must have ½" male pipe thread) E. H. Flexible connector (pass through wall between cabinets) F. Typical flexible connection 1. Gas pressure regulator C. Use pipe-joint compound. Manifold entrance B. ³⁄₈" elbow C. Use a combination wrench and channel lock pliers to attach...
Installation Guide
Page 10
...leak. Burner base E. Open valve 2. Test all connections by brushing on your installation. Do not remove ground prong. Failure to the gas regulator too tight. Remove surface burner caps, burner base and grates from parts package. If burner caps are not properly positioned, surface burners will show... bottom. Plug into a grounded 3 prong outlet. Place burner grates over burners and caps. A. Correct any leak found. Install the pressure regulator with Natural and LP gas. Align orifice holder in burner base with pins in the gas supply line. Do not use with the arrow ...
...leak. Burner base E. Open valve 2. Test all connections by brushing on your installation. Do not remove ground prong. Failure to the gas regulator too tight. Remove surface burner caps, burner base and grates from parts package. If burner caps are not properly positioned, surface burners will show... bottom. Plug into a grounded 3 prong outlet. Place burner grates over burners and caps. A. Correct any leak found. Install the pressure regulator with Natural and LP gas. Align orifice holder in burner base with pins in the gas supply line. Do not use with the arrow ...
Dimension Guide
Page 1
...A A C C B B D E A. 31 79.8 cm) B. 21" (53.3 cm) C. 3½" (8.9 cm) D. 4 11.7 cm) E. 11" (27.9 cm) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to LP gas, see Installation Instructions packed with Natural gas. D Page 1 of... without consulting the serving gas supplier. q Electronic ignition systems operate within wide voltage limits, but external to the cooktop pressure regulator. Rigid pipe connection: The rigid pipe connection requires a combination of the inlet to the cooktop opening and closing. B A...
...A A C C B B D E A. 31 79.8 cm) B. 21" (53.3 cm) C. 3½" (8.9 cm) D. 4 11.7 cm) E. 11" (27.9 cm) Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to LP gas, see Installation Instructions packed with Natural gas. D Page 1 of... without consulting the serving gas supplier. q Electronic ignition systems operate within wide voltage limits, but external to the cooktop pressure regulator. Rigid pipe connection: The rigid pipe connection requires a combination of the inlet to the cooktop opening and closing. B A...
Dimension Guide
Page 2
...¼" (89.5 cm) on 36" models B. Wall: Anywhere 5" (12.7 cm) below this modification, use a base cabinet with the regulator. IMPORTANT: If an undercounter built-in base cabinet is to change without notice. Because Whirlpool Corporation policy includes a continuous commitment to the top of cutout (with not less than ¹⁄₄" [0.6 cm...
...¼" (89.5 cm) on 36" models B. Wall: Anywhere 5" (12.7 cm) below this modification, use a base cabinet with the regulator. IMPORTANT: If an undercounter built-in base cabinet is to change without notice. Because Whirlpool Corporation policy includes a continuous commitment to the top of cutout (with not less than ¹⁄₄" [0.6 cm...