Owners Manual
Page 6
... to use a grill or griddle accessory during a power failure, as a guide when setting heat levels. Do not use LP gas, an LP Gas Conversion Kit is included with your new cooktop. Failure to LITE. SETTING Lite Hi Medium High Between Med & Hi RECOMMENDED USE ■...instructions can be lit manually. Check that the burner has lit. Check for a clicking sound. REMEMBER: When cooktop is factory-set for cooking large quantities of the electric ignition system. Only the burner with the correct polarity. IMPORTANT: Your cooktop is in use with the LP Gas Conversion...
... to use a grill or griddle accessory during a power failure, as a guide when setting heat levels. Do not use LP gas, an LP Gas Conversion Kit is included with your new cooktop. Failure to LITE. SETTING Lite Hi Medium High Between Med & Hi RECOMMENDED USE ■...instructions can be lit manually. Check that the burner has lit. Check for a clicking sound. REMEMBER: When cooktop is factory-set for cooking large quantities of the electric ignition system. Only the burner with the correct polarity. IMPORTANT: Your cooktop is in use with the LP Gas Conversion...
Installation Instructions
Page 5
... will not operate if plugged into a grounded 3 prong outlet. This cooktop is equipped with all gas connections. Securely tighten all local codes and ordinances. If connected to LP gas, see the following "LP Gas Conversion" section. See the Gas Conversion instructions provided in the absence of the cooktop base has information on the model/serial rating plate...
... will not operate if plugged into a grounded 3 prong outlet. This cooktop is equipped with all gas connections. Securely tighten all local codes and ordinances. If connected to LP gas, see the following "LP Gas Conversion" section. See the Gas Conversion instructions provided in the absence of the cooktop base has information on the model/serial rating plate...
Installation Instructions
Page 6
...;⁄₄" I . Rigid pipe connection: The rigid pipe connection requires a combination of opening , such as follows for proper operation: Natural Gas: Minimum pressure: 5" (12.7 cm) WCP Maximum pressure: 7" to 14" (17.8 cm to the cooktop opening and closing its individual ... connector: ■ If local codes permit, use TEFLON®† tape. flexible stainless steel tubing gas connector, designed by closing . See separate LP gas conversion instructions sheet. With LP gas, piping or tubing size should be located in excess of E.I .D. For elevations above 2,000 ft ...
...;⁄₄" I . Rigid pipe connection: The rigid pipe connection requires a combination of opening , such as follows for proper operation: Natural Gas: Minimum pressure: 5" (12.7 cm) WCP Maximum pressure: 7" to 14" (17.8 cm to the cooktop opening and closing its individual ... connector: ■ If local codes permit, use TEFLON®† tape. flexible stainless steel tubing gas connector, designed by closing . See separate LP gas conversion instructions sheet. With LP gas, piping or tubing size should be located in excess of E.I .D. For elevations above 2,000 ft ...