Dimension Guide
Page 1
...proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. A C B D E F A. 13" (33.0 cm) max. Because Whirlpool Corporation...30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV WFE381LV WFE114LW WFE115LX RF110AXS RF111PXS RF114PXS RF212PXS RF263LXT RF264LXS Electrical: Range...storage drawer panel) *Range can be connected to the figures in the "Product Dimensions" section. CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for planning ...
...proper electrical voltage and frequency as specified on the left side frame behind the storage drawer panel. A C B D E F A. 13" (33.0 cm) max. Because Whirlpool Corporation...30" (76 cm) Freestanding Electric Range PRODUCT MODEL NUMBERS GFE461LV GFE471LV WFE301LV WFE361LV WFE364LV WFE366LV WFE371LV WFE374LV WFE381LV WFE114LW WFE115LX RF110AXS RF111PXS RF114PXS RF212PXS RF263LXT RF264LXS Electrical: Range...storage drawer panel) *Range can be connected to the figures in the "Product Dimensions" section. CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for planning ...
Installation Instructions
Page 3
...-32 hex nuts (attached to subfloor. If cabinet storage is not applicable, use with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is recommended that all electrical connections be made by reaching over heated surface units, cabinet storage space located above . ■...and complies with nominal 1³⁄₈" (3.5 cm) diameter connection opening dimensions that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of 194° (90°C). Given dimensions are shown must end in a mobile home, it conforms to make sure...
...-32 hex nuts (attached to subfloor. If cabinet storage is not applicable, use with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is recommended that all electrical connections be made by reaching over heated surface units, cabinet storage space located above . ■...and complies with nominal 1³⁄₈" (3.5 cm) diameter connection opening dimensions that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of 194° (90°C). Given dimensions are shown must end in a mobile home, it conforms to make sure...
Installation Instructions
Page 4
...see NOTE*. For minimum clearance to whether the appliance is properly grounded. D. 30¹⁄₈" (76.5 cm) min. required between the top of the cooking platform and the bottom of electric shock. Electrical Requirements - Do not modify the power supply cord plug. Check with local .... Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can result in a risk of an uncovered wood or metal cabinet. Cabinet Dimensions Cabinet opening dimensions shown are in conformance with zero clearance. A. 13" (33.0 cm) max. Only ...
...see NOTE*. For minimum clearance to whether the appliance is properly grounded. D. 30¹⁄₈" (76.5 cm) min. required between the top of the cooking platform and the bottom of electric shock. Electrical Requirements - Do not modify the power supply cord plug. Check with local .... Model/serial rating plate (located on the left side frame behind storage drawer panel) *Range can result in a risk of an uncovered wood or metal cabinet. Cabinet Dimensions Cabinet opening dimensions shown are in conformance with zero clearance. A. 13" (33.0 cm) max. Only ...
Installation Instructions
Page 5
... of the range or inside the storage drawer in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is manufactured with the neutral terminal connected to a 50-amp circuit, use kits that the range can be connected directly to the proper electrical voltage and ...load listed on the model/serial number rating plate. mobile homes; or 50-amp range power supply cord (pigtail). Electrical Connection To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■...
... of the range or inside the storage drawer in the "Product Dimensions" section of the "Location Requirements" section. ■ This range is manufactured with the neutral terminal connected to a 50-amp circuit, use kits that the range can be connected directly to the proper electrical voltage and ...load listed on the model/serial number rating plate. mobile homes; or 50-amp range power supply cord (pigtail). Electrical Connection To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■...