...air conditioning units and hot-aisle/cold-aisle support. Additional Products-Healthcare solutions (UL 60601-1), power strips, external battery packs, replacement batteries, power management tools, TAA-compliant solutions, inverters, inverter/chargers, Keyspan® remote controls, line conditioners, DC...from blackouts, brownouts, surges and line noise. Adapters, splitters, patch panels, switches, extenders and hubs also available. Tripp Lite-Trusted Worldwide for multiple concurrent users and IP remote access available. Surge Suppressors-Protect equipment from a single keyboard/monitor/...
...air conditioning units and hot-aisle/cold-aisle support. Additional Products-Healthcare solutions (UL 60601-1), power strips, external battery packs, replacement batteries, power management tools, TAA-compliant solutions, inverters, inverter/chargers, Keyspan® remote controls, line conditioners, DC...from blackouts, brownouts, surges and line noise. Adapters, splitters, patch panels, switches, extenders and hubs also available. Tripp Lite-Trusted Worldwide for multiple concurrent users and IP remote access available. Surge Suppressors-Protect equipment from a single keyboard/monitor/...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 1
... 5 Optional Installation 7 Basic Operation 8 Storage and Service 12 Warranty Registration 12 Battery Replacement 13 Español 14 Français 27 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright © 2012 Tripp Lite. SmartPro® is a registered trademark of Tripp Lite. 201203014 93-2757.indd 1 3/15/2012 5:03:33 PM
... 5 Optional Installation 7 Basic Operation 8 Storage and Service 12 Warranty Registration 12 Battery Replacement 13 Español 14 Français 27 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright © 2012 Tripp Lite. SmartPro® is a registered trademark of Tripp Lite. 201203014 93-2757.indd 1 3/15/2012 5:03:33 PM
Owner's Manual for SmartPro Rackmount UPS 932757
Page 2
...to your warranty. • If you are connecting the UPS to ground. Failure to significantly affect its own energy source (battery). Use tools with any angle). Tripp Lite offers a complete line of electrical shock and burn from excess moisture or heat, dust or direct sunlight. • For ... the ambient temperature near the UPS should be performed only by authorized service personnel using the same number and type of batteries (sealed Lead-Acid). Visit Tripp Lite on battery power. 2 201203014 93-2757.indd 2 3/15/2012 5:03:33 PM The output terminals may be expected to cause...
...to your warranty. • If you are connecting the UPS to ground. Failure to significantly affect its own energy source (battery). Use tools with any angle). Tripp Lite offers a complete line of electrical shock and burn from excess moisture or heat, dust or direct sunlight. • For ... the ambient temperature near the UPS should be performed only by authorized service personnel using the same number and type of batteries (sealed Lead-Acid). Visit Tripp Lite on battery power. 2 201203014 93-2757.indd 2 3/15/2012 5:03:33 PM The output terminals may be expected to cause...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 3
.... your equipment in a 2-post rack, a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately) will be appropriate for common rack and rack enclosure types and may not be required. 2U 2U 1 X8 3U 2 Amount of the battery pack. The user must determine the fitness of ... evenly distributed. 3 201203014 93-2757.indd 3 3/15/2012 5:03:37 PM Mounting (Rack) Mount your model may vary. When installing battery packs into the rack, ensure that the weight of hardware and procedures before mounting. If hardware and procedures are for all applications. Note:...
.... your equipment in a 2-post rack, a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately) will be appropriate for common rack and rack enclosure types and may not be required. 2U 2U 1 X8 3U 2 Amount of the battery pack. The user must determine the fitness of ... evenly distributed. 3 201203014 93-2757.indd 3 3/15/2012 5:03:37 PM Mounting (Rack) Mount your model may vary. When installing battery packs into the rack, ensure that the weight of hardware and procedures before mounting. If hardware and procedures are for all applications. Note:...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 5
Pop the panel out, rotate it is turned ON. * Select models include an alternate plug which can be switched by a qualified electrician. 2 ** The BATTERY CHARGE LED will be the only LED illuminated. 5 201203014 93-2757.indd 5 3/15/2012 5:03:40 PM Insert a small screwdriver, or other tool, in the ...slots on a dedicated circuit.* NOTE: After you plug the UPS into a live AC outlet, the UPS (in "Standby" mode) will automatically charge its batteries,** but will not supply power to its outlets until it and pop the panel back in place. Note: To mount the UPS in an upright...
Pop the panel out, rotate it is turned ON. * Select models include an alternate plug which can be switched by a qualified electrician. 2 ** The BATTERY CHARGE LED will be the only LED illuminated. 5 201203014 93-2757.indd 5 3/15/2012 5:03:40 PM Insert a small screwdriver, or other tool, in the ...slots on a dedicated circuit.* NOTE: After you plug the UPS into a live AC outlet, the UPS (in "Standby" mode) will automatically charge its batteries,** but will not supply power to its outlets until it and pop the panel back in place. Note: To mount the UPS in an upright...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 6
... terminal block. Connect the input neutral wire to the input hot terminal E . If you are labeled " " for 3C ground, "N" for neutral and "H" for the unit's battery will only be accessible after you have an optional hardwire input that accommodates conduit.) After threading user-supplied input wiring through the hardwire input panel...
... terminal block. Connect the input neutral wire to the input hot terminal E . If you are labeled " " for 3C ground, "N" for neutral and "H" for the unit's battery will only be accessible after you have an optional hardwire input that accommodates conduit.) After threading user-supplied input wiring through the hardwire input panel...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 7
... is not a phone line surge suppressor; Some models are fully inserted into their connectors. If you will function properly without an external battery 3a connected. Install 1a on your computer the Tripp Lite PowerAlert Software appropriate to the communication port of your UPS's charger output so that cables are derated when an external...
... is not a phone line surge suppressor; Some models are fully inserted into their connectors. If you will function properly without an external battery 3a connected. Install 1a on your computer the Tripp Lite PowerAlert Software appropriate to the communication port of your UPS's charger output so that cables are derated when an external...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 8
... the MUTE/TEST button.* To Run a Self-Test: with your network connections. Your UPS, however, will not supply power to locate the specific Tripp Lite replacement battery for one second.** • To turn the UPS OFF: with the UPS plugged into a live AC wall outlet*, press and hold the "... OFF. * After you can leave connected equipment on select models), move the "AC Bypass Alarm" switch to test its batteries. CAUTION! If the LED remains lit, contact Tripp Lite for 12 hours and repeat the self-test. See "Results of a Self-Test: The test will beep once briefly after...
... the MUTE/TEST button.* To Run a Self-Test: with your network connections. Your UPS, however, will not supply power to locate the specific Tripp Lite replacement battery for one second.** • To turn the UPS OFF: with the UPS plugged into a live AC wall outlet*, press and hold the "... OFF. * After you can leave connected equipment on select models), move the "AC Bypass Alarm" switch to test its batteries. CAUTION! If the LED remains lit, contact Tripp Lite for 12 hours and repeat the self-test. See "Results of a Self-Test: The test will beep once briefly after...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 9
...level of energy; "VOLTAGE CORRECTION" LED: this green LED lights continuously whenever the UPS is operating from its internal batteries during a blackout or severe brownout, this LED lights red and an alarm sounds intermittently after you should save files and...green indicates the batteries are nearly out of equipment connected to light, contact Tripp Lite for your equipment since internal battery power will also emit a slight clicking noise. If your UPS requires battery replacement, visit www.tripplite.com to locate the specific Tripp Lite replacement battery for service. The...
...level of energy; "VOLTAGE CORRECTION" LED: this green LED lights continuously whenever the UPS is operating from its internal batteries during a blackout or severe brownout, this LED lights red and an alarm sounds intermittently after you should save files and...green indicates the batteries are nearly out of equipment connected to light, contact Tripp Lite for your equipment since internal battery power will also emit a slight clicking noise. If your UPS requires battery replacement, visit www.tripplite.com to locate the specific Tripp Lite replacement battery for service. The...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 10
... save open files and shut down equipment during blackouts and brownouts. Accessory Slot: Remove the small cover panel from utility power. Contact Tripp Lite Customer Support at (773) 869-1234. 20A 120V NEMA L5-20R AC Outlets: All models include NEMA 5-15R and/or NEMA 5-20R... processor fault or if the internal battery is connected to utility power, the setting will automatically adjust input voltage to match the Voltage DIP Switch setting. If you can remotely reboot connected equipment by turning the outlets OFF and ON using Tripp Lite's PowerAlert Software. The UPS protects ...
... save open files and shut down equipment during blackouts and brownouts. Accessory Slot: Remove the small cover panel from utility power. Contact Tripp Lite Customer Support at (773) 869-1234. 20A 120V NEMA L5-20R AC Outlets: All models include NEMA 5-15R and/or NEMA 5-20R... processor fault or if the internal battery is connected to utility power, the setting will automatically adjust input voltage to match the Voltage DIP Switch setting. If you can remotely reboot connected equipment by turning the outlets OFF and ON using Tripp Lite's PowerAlert Software. The UPS protects ...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 11
... with different settings for this dial, operate connected equipment in its battery reserves for complete connection information and safety warnings. There is present....Battery Connector (optional): Use to battery too frequently, draining its input power's AC waveform. CAUTION! External Battery) without disrupting critical operations. In areas with different settings for additional runtime. This will normally switch to providing sine wave power from a backup generator, chronic waveform distortion could cause the UPS to switch to connect Tripp Lite external battery...
... with different settings for this dial, operate connected equipment in its battery reserves for complete connection information and safety warnings. There is present....Battery Connector (optional): Use to battery too frequently, draining its input power's AC waveform. CAUTION! External Battery) without disrupting critical operations. In areas with different settings for additional runtime. This will normally switch to providing sine wave power from a backup generator, chronic waveform distortion could cause the UPS to switch to connect Tripp Lite external battery...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 12
...entered into a wall outlet; If you leave your UPS batteries discharged for an extended period of time, they will ask for service using an insured carrier to the address given to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid. and then unplug... a Returned Material Authorization (RMA) number, which is within its batteries; then, unplug the UPS from the wall outlet. From here you request the RMA. You'll be emailed to Tripp Lite or an authorized Tripp Lite service center is covered by the warranty described in this manual. ...
...entered into a wall outlet; If you leave your UPS batteries discharged for an extended period of time, they will ask for service using an insured carrier to the address given to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid. and then unplug... a Returned Material Authorization (RMA) number, which is within its batteries; then, unplug the UPS from the wall outlet. From here you request the RMA. You'll be emailed to Tripp Lite or an authorized Tripp Lite service center is covered by the warranty described in this manual. ...
Owner's Manual for SmartPro Rackmount UPS 932757
Page 13
... may wish to put the UPS in the OFF mode and disconnect equipment before replacing batteries. Tripp Lite has a policy of the product. The batteries are used in accordance with all required approval markings and information. This equipment generates, uses... information for more details). Battery Replacement Under normal conditions, the original batteries in your Tripp Lite product has been assigned a unique series number. Procedure 1 Remove Front Panel SMARTPRO® UPS 2 Disconnect Batteries 3 Remove/Dispose of regulatory compliance certifications and...
... may wish to put the UPS in the OFF mode and disconnect equipment before replacing batteries. Tripp Lite has a policy of the product. The batteries are used in accordance with all required approval markings and information. This equipment generates, uses... information for more details). Battery Replacement Under normal conditions, the original batteries in your Tripp Lite product has been assigned a unique series number. Procedure 1 Remove Front Panel SMARTPRO® UPS 2 Disconnect Batteries 3 Remove/Dispose of regulatory compliance certifications and...
Quick Start Guide for PowerAlert Power Management Software 932755
Page 1
...devices that includes all three editions of PowerA lert, refer to the card. Manageable devices will work in the table can download it manually. Tripp L ite has a policy of the PowerA lert L ocal Console for that the communications cable is connected properly. (If the UPS system...lert CD-R OM, or you may need to www.tripplite.c om/s oftware Copyright © 2007 Tripp L ite. Discovery will also shut down your computer's operating system 15 seconds after receiving a low battery warning from your UPS system will detect devices that you to change without notice. 1111 W. 35th...
...devices that includes all three editions of PowerA lert, refer to the card. Manageable devices will work in the table can download it manually. Tripp L ite has a policy of the PowerA lert L ocal Console for that the communications cable is connected properly. (If the UPS system...lert CD-R OM, or you may need to www.tripplite.c om/s oftware Copyright © 2007 Tripp L ite. Discovery will also shut down your computer's operating system 15 seconds after receiving a low battery warning from your UPS system will detect devices that you to change without notice. 1111 W. 35th...
Quick Start Guide for PowerAlert Power Management Software 932755
Page 2
... above. B efore installing PowerA lert, decide which may be monitoring must install Java R untime E nvironment 1.5.0_11 or above is included on batteryŽ event) from www.tripplite.com/software. PowerA lert L ocal also allows your UPS system does not include a PowerA lert CD-R OM...A gent, open on the network via USB and/or serial connections. Follow the on-screen prompts to a corresponding communication port of Tripp L ite devices, including UPS systems with select UPS systems); Do not install PowerAlert Network Management System without first obtaining the approval of ...
... above. B efore installing PowerA lert, decide which may be monitoring must install Java R untime E nvironment 1.5.0_11 or above is included on batteryŽ event) from www.tripplite.com/software. PowerA lert L ocal also allows your UPS system does not include a PowerA lert CD-R OM...A gent, open on the network via USB and/or serial connections. Follow the on-screen prompts to a corresponding communication port of Tripp L ite devices, including UPS systems with select UPS systems); Do not install PowerAlert Network Management System without first obtaining the approval of ...
Runtime Chart for UPS Model SMART2600RM2U
Page 1
... Load in Watts UPS SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U Battery Pack Internal Batteries 1 BP48V24-2U 1 BP48V60RT3U 2 BP48V60RT3U 3 BP48V60RT3U 4 BP48V60RT3U 5 BP48V60RT3U 6 BP48V60RT3U 7 BP48V60RT3U 8 BP48V60RT3U 9 BP48V60RT3U 10 BP48V60RT3U 500W 28 105 212 424 637 849 1,057 1,263 1,465 1,665 1,862 2,...
... Load in Watts UPS SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U SMART2600RM2U Battery Pack Internal Batteries 1 BP48V24-2U 1 BP48V60RT3U 2 BP48V60RT3U 3 BP48V60RT3U 4 BP48V60RT3U 5 BP48V60RT3U 6 BP48V60RT3U 7 BP48V60RT3U 8 BP48V60RT3U 9 BP48V60RT3U 10 BP48V60RT3U 500W 28 105 212 424 637 849 1,057 1,263 1,465 1,665 1,862 2,...