Installation Instructions
Page 6
... mm) A Rear View C B 12 13/16" (325 mm) 11/16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857...
... mm) A Rear View C B 12 13/16" (325 mm) 11/16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857...
Installation Instructions
Page 7
This model series features brushed stainless-steel filters, halogen lights, hood liner, and a 1000CFM integral blower. 15/8" (42mm) 45/16" (110 mm) Top View 21¾" (553 mm) A B 24¾" (629 mm) C 36 po 40½" (1,...) 223/16" (564 mm) 44Ǫ" (1,127 mm) 253/16" (640 mm) 50Ǫ" (1,280 mm) A Rear View C B 14 5/16" (363 mm) Table 2: VCIB Custom Insert Overall Dimensions English 5 VCIBxxJP Overall Dimensions VCIBxxJP - 24" (610 mm) in depth and with widths of 41½" (1,054 mm), 52½" (1,334 mm) or...
This model series features brushed stainless-steel filters, halogen lights, hood liner, and a 1000CFM integral blower. 15/8" (42mm) 45/16" (110 mm) Top View 21¾" (553 mm) A B 24¾" (629 mm) C 36 po 40½" (1,...) 223/16" (564 mm) 44Ǫ" (1,127 mm) 253/16" (640 mm) 50Ǫ" (1,280 mm) A Rear View C B 14 5/16" (363 mm) Table 2: VCIB Custom Insert Overall Dimensions English 5 VCIBxxJP Overall Dimensions VCIBxxJP - 24" (610 mm) in depth and with widths of 41½" (1,054 mm), 52½" (1,334 mm) or...
Installation Instructions
Page 8
... of 30" (762 mm) to Countertop Figure 1: Typical Hood Installation NOTICE: The hood could incur some damage from heat if a THERMADOR PROFESSIONAL® series range or rangetop is operated with Blowers ....11 kg) VCIN54JP 82 lb (37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied... a wider hood can vary. Distance From Cooking Surface The installation height ranges from a minimum height of the cooking surface. Installation Preparation The custom insert unit is installed at minimum clearances. Hood installation height...
... of 30" (762 mm) to Countertop Figure 1: Typical Hood Installation NOTICE: The hood could incur some damage from heat if a THERMADOR PROFESSIONAL® series range or rangetop is operated with Blowers ....11 kg) VCIN54JP 82 lb (37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied... a wider hood can vary. Distance From Cooking Surface The installation height ranges from a minimum height of the cooking surface. Installation Preparation The custom insert unit is installed at minimum clearances. Hood installation height...
Installation Instructions
Page 12
...applicable local codes, this may be connected to saturation with the CAN 1- When connected to a GFCI-protected supply, THERMADOR PROFESSIONAL® custom insert hoods are protected from outside weather conditions and not subject to its own circuit. • If the grounded socket is located...straight run . In the U.S., if there are available for Gas Burning Appliances and/or local codes. Installation Codes for THERMADOR PROFESSIONAL® custom insert series hoods. The appliance must be in accordance with the National Electric Code ANSI/NFPA No. 70, Current Issue. Choosing the ...
...applicable local codes, this may be connected to saturation with the CAN 1- When connected to a GFCI-protected supply, THERMADOR PROFESSIONAL® custom insert hoods are protected from outside weather conditions and not subject to its own circuit. • If the grounded socket is located...straight run . In the U.S., if there are available for Gas Burning Appliances and/or local codes. Installation Codes for THERMADOR PROFESSIONAL® custom insert series hoods. The appliance must be in accordance with the National Electric Code ANSI/NFPA No. 70, Current Issue. Choosing the ...
Installation Instructions
Page 15
.../8" (327 mm) dia. 97/8" (251 mm) 203/4" 10" (527 mm) (254 mm) 19 7/8" (505 mm) Figure 8: VTR1330E Remote Blower Custom insert models can be replaced with remote blowers (VCIN models). Connect the remote blower to the connector inside the junction box. 7. Close the junction box cover... Lost or missing wire nuts should only be installed with spring type wire nuts, rated for further wiring details. 9. Figure 9: Wiring the Hood with the blower unit. 1. Remove junction box channel covering the wires (see the instructions supplied with a Remote Blower English 13 For complete ...
.../8" (327 mm) dia. 97/8" (251 mm) 203/4" 10" (527 mm) (254 mm) 19 7/8" (505 mm) Figure 8: VTR1330E Remote Blower Custom insert models can be replaced with remote blowers (VCIN models). Connect the remote blower to the connector inside the junction box. 7. Close the junction box cover... Lost or missing wire nuts should only be installed with spring type wire nuts, rated for further wiring details. 9. Figure 9: Wiring the Hood with the blower unit. 1. Remove junction box channel covering the wires (see the instructions supplied with a Remote Blower English 13 For complete ...
Installation Instructions
Page 16
Run five (5) wires (#14 AWG) in the junction box. 9. Figure 11: Wiring the Hood with the blower unit. 12 1/8" (308 mm) 12 " (305 mm) 7/8" (22 mm) ø 9 7/8" (251 mm)...mm) Figure 10: VTI1010D Inline Blower 1. Remove circular knockouts (Figure 5 on chassis. Wiring the Hood with an Inline Blower Both VCIN and VCIB custom insert models can be replaced with spring type wire nuts, rated for a minimum of two (2 #...wire to junction box. 5. Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from the inline blower to the connector inside the junction box. 7.
Run five (5) wires (#14 AWG) in the junction box. 9. Figure 11: Wiring the Hood with the blower unit. 12 1/8" (308 mm) 12 " (305 mm) 7/8" (22 mm) ø 9 7/8" (251 mm)...mm) Figure 10: VTI1010D Inline Blower 1. Remove circular knockouts (Figure 5 on chassis. Wiring the Hood with an Inline Blower Both VCIN and VCIB custom insert models can be replaced with spring type wire nuts, rated for a minimum of two (2 #...wire to junction box. 5. Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from the inline blower to the connector inside the junction box. 7.
Installation Instructions
Page 17
b) Remove the junction box cover (refer to the hood after the hood is installed. 1. Remote Harness Remove 3x screws Harness Mounting Hole Figure 14: Remote Harness Mounting Hole b) Run harness through Partition c) Unplug harness from the remote...: Remove stainless steel panel d) Remove core partition (Figure 13). Figure 13: Remove core partition English 15 Remote Control Installation (optional) NOTE: When using the Custom Insert with remote the unit loses the "AUTO" function and the over-temperature heat sensor described in Figure 14, until it clicks. Access wiring a) Remove filters...
b) Remove the junction box cover (refer to the hood after the hood is installed. 1. Remote Harness Remove 3x screws Harness Mounting Hole Figure 14: Remote Harness Mounting Hole b) Run harness through Partition c) Unplug harness from the remote...: Remove stainless steel panel d) Remove core partition (Figure 13). Figure 13: Remove core partition English 15 Remote Control Installation (optional) NOTE: When using the Custom Insert with remote the unit loses the "AUTO" function and the over-temperature heat sensor described in Figure 14, until it clicks. Access wiring a) Remove filters...
Installation Instructions
Page 19
Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. Figure 19: Remote Install English 17 4. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Insert remote control into cutout. Secure from Figure 12 and Figure 13.
Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. Figure 19: Remote Install English 17 4. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Insert remote control into cutout. Secure from Figure 12 and Figure 13.
Installation Instructions
Page 23
...a) Refer to "Blower Motor Installation" beginning on accidentally. ½" (12.7 mm) x18 CAUTION: The hood weighs at least 60 lbs; Figure 25: VCIN Trim Installation 6. WARNING: To avoid electrical shock hazard, ... VCINxxJP Housing Framework" beginning on page 6 for applicable model according to the bottom of the housing. Install hood trim a) Hold trim flush to dimensions in Figure 25. c) Build housing framework for clearance specifications. Use caution ... property damage or personal injury. 1. Install the unit a) Install the custom insert inside the custom hood.
...a) Refer to "Blower Motor Installation" beginning on accidentally. ½" (12.7 mm) x18 CAUTION: The hood weighs at least 60 lbs; Figure 25: VCIN Trim Installation 6. WARNING: To avoid electrical shock hazard, ... VCINxxJP Housing Framework" beginning on page 6 for applicable model according to the bottom of the housing. Install hood trim a) Hold trim flush to dimensions in Figure 25. c) Build housing framework for clearance specifications. Use caution ... property damage or personal injury. 1. Install the unit a) Install the custom insert inside the custom hood.
Installation Instructions
Page 24
c) Secure to the sides of the blower and the lights. Connect to "Installing Grease Trays, Filter Spacers, and Filters" on page 28. 10. Install hood filters, filter spacers, and grease trays a) Refer to ductwork 8. c) Connect wiring for applicable blower motor (see Figure 5 on high, close the windows and doors to ... in the OFF position. d) Ensure all controls are in any outlet vent for backdraft. b) Remove circular knock-out holes located on back side of the insert (see Figure 5 on page 11).
c) Secure to the sides of the blower and the lights. Connect to "Installing Grease Trays, Filter Spacers, and Filters" on page 28. 10. Install hood filters, filter spacers, and grease trays a) Refer to ductwork 8. c) Connect wiring for applicable blower motor (see Figure 5 on high, close the windows and doors to ... in the OFF position. d) Ensure all controls are in any outlet vent for backdraft. b) Remove circular knock-out holes located on back side of the insert (see Figure 5 on page 11).
Installation Instructions
Page 29
... sides of the blower and the lights. With the blower on high, close the windows and doors to the area to the rear of the insert (see Figure 5 on page 11). Test the installation. Connect Electric a) Remove the junction box cover (see blower instructions beginning on page 11). ½" ...circular knock-out holes located on page 11). a) Test the operation of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 37). 7. Install Hood Filters and Grease Trays a) Refer to Ductwork 8. Plug electrical cord into grounded outlet. 9. Install the Unit a) Install the custom...
... sides of the blower and the lights. With the blower on high, close the windows and doors to the area to the rear of the insert (see Figure 5 on page 11). Test the installation. Connect Electric a) Remove the junction box cover (see blower instructions beginning on page 11). ½" ...circular knock-out holes located on page 11). a) Test the operation of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 37). 7. Install Hood Filters and Grease Trays a) Refer to Ductwork 8. Plug electrical cord into grounded outlet. 9. Install the Unit a) Install the custom...
Installation Instructions
Page 30
... the filters. The grease trays must be from 2 or 3 grease trays per hood. 3. push down and in . Reverse the above directions to 4 filters per hood. Insert in at the bottom. Depending upon the size and model of hood, there will be from hood pieces. 2. c) Filters - Remove all plastic from 2 to remove the grease trays, filter...
... the filters. The grease trays must be from 2 or 3 grease trays per hood. 3. push down and in . Reverse the above directions to 4 filters per hood. Insert in at the bottom. Depending upon the size and model of hood, there will be from hood pieces. 2. c) Filters - Remove all plastic from 2 to remove the grease trays, filter...
User Manual
Page 6
Pay special attention to read this manual. This manual provides information for two styles of THERMADOR PROFESSIONAL® custom insert hoods: • VCINxxJP - 22" (559 mm) in depth, and with widths of 41½" (1,054 mm), 52½" (1,334 mm) or 58½" (1,486 ...for additional options. Use only THERMADOR® blowers with widths of a remote, inline, or integral blower. Contact Customer Service for more details. All VCINxxJP hoods require the choice of 33¾" (857 mm), 45¾" (1,162 mm) or 51¾" (1,315 mm). Figure 1: Custom Insert BLOWER REMOTE BLOWER 600 CFM REMOTE...
Pay special attention to read this manual. This manual provides information for two styles of THERMADOR PROFESSIONAL® custom insert hoods: • VCINxxJP - 22" (559 mm) in depth, and with widths of 41½" (1,054 mm), 52½" (1,334 mm) or 58½" (1,486 ...for additional options. Use only THERMADOR® blowers with widths of a remote, inline, or integral blower. Contact Customer Service for more details. All VCINxxJP hoods require the choice of 33¾" (857 mm), 45¾" (1,162 mm) or 51¾" (1,315 mm). Figure 1: Custom Insert BLOWER REMOTE BLOWER 600 CFM REMOTE...
User Manual
Page 9
Thus when heat, smoke, moisture, grease and cooking odors are those created by the blower itself. HIGH Hood Control Buttons Custom Insert Control Panel Auto (custom insert control panel only) When in order to be cleaned. MED 3 - Auto feature is disabled if a remote control is pressed, the...and the higher speed for 10 minutes at the current speed then turns off. It automatically adjusts every 5 minutes. Figure 2: Custom Insert Control Panel Clean Filter Reminder After 40 hours of ventilation in the kitchen is done where the only air currents are produced, they will...
Thus when heat, smoke, moisture, grease and cooking odors are those created by the blower itself. HIGH Hood Control Buttons Custom Insert Control Panel Auto (custom insert control panel only) When in order to be cleaned. MED 3 - Auto feature is disabled if a remote control is pressed, the...and the higher speed for 10 minutes at the current speed then turns off. It automatically adjusts every 5 minutes. Figure 2: Custom Insert Control Panel Clean Filter Reminder After 40 hours of ventilation in the kitchen is done where the only air currents are produced, they will...
User Manual
Page 10
...control will remain operational. All the controls will blink, indicating an overtemperature condition. A second press dims the lights. OFF Heat Sensor (custom insert control panel only) Heat sensor feature is disabled if a remote control is not working due to activate at 161 °F (72 °C) ...case of this extreme condition, the three fan speed indicator LEDs will occur. Over-temperature Condition The high temperature sensor protects the hood from high temperatures which may damage components. Lights This button controls the halogen lighting. A third press turns the lights off ....
...control will remain operational. All the controls will blink, indicating an overtemperature condition. A second press dims the lights. OFF Heat Sensor (custom insert control panel only) Heat sensor feature is disabled if a remote control is not working due to activate at 161 °F (72 °C) ...case of this extreme condition, the three fan speed indicator LEDs will occur. Over-temperature Condition The high temperature sensor protects the hood from high temperatures which may damage components. Lights This button controls the halogen lighting. A third press turns the lights off ....