Sharp AF-05CML Support and Manuals

Get Help and Manuals for this Sharp item

View All Support Options Below
Free Sharp AF-05CML manuals!
Problems with Sharp AF-05CML?

Ask a Question

Popular Sharp AF-05CML Manual Pages

Service Manual - Page 1

... ...7 HOW TO REPAIR REFRIGERATION ...10 ELECTRICAL COMPONENT TEST ...12 TROUBLESHOOTING GUIDE ...13 COOLING LOAD ESTIMATE FORM ...16 RUNNING CONDITION ...18 PACKING AND ACCESSORIES ...19 REPLACEMENT PARTS LIST ...20 SHARP CORPORATION This document has been published to be used for after sales service only. AF-05CML SERVICE MANUAL S3209AF05CML/ AIR CONDITIONER MODEL AF-05CML In the interests...
Service Manual - Page 2

...Air flow rate(indoor side) CFM OTHERS Safety devices Air filter Power cord length ft Power plug type ELECTRICAL PARTS Running capacitor Fan capacitor Selector switch Thermistor Fan motor Overload relay AF-05CML...181;F 250V-6µF 2109 No. APPLI- COLD . x I.D. AF-05CML SPECIFICATIONS Models Cooling capacity BTU/h Moisture removal Pints/h ELECTRICAL DATA Phase Rared ...
Service Manual - Page 4

AF-05CML HOW TO OPERATE HOW TO OPERATE PARTS NAMES UNIT 3 4 5 6 7 8 9 10 2 1 11 1 Front Cabinet 2 Air Inlet (Indoor Side) 3 Horizontal Louvers 4 Vertical Louvers 5 Air Outlet (Indoor Side) 6 Control Panel 7 Rear Cabinet 8 Air Inlet (Outdoor Side) 9 FiIter (Pull the filter handle to the right to circulate air whenever cooling is not desired. FAN This setting can adjust the cooling ...
Service Manual - Page 5

... the air conditioner on the sill and close the window sash securely behind the top angle. 4. Secure the right and left closure assembly into the top angle and the bottom channels. If there is inclinedapproximately 1 cm (3/8") to the underside of the unit to the cabinet with a thin board or other hard filler. AF-05CML INSTALLATION INSTALLATIONS...
Service Manual - Page 11

...since air conditioners run with the refrigerant oil to 1/2 mm. The use of compressors. AF-05CML OUTER CONE HOTTEST PART OF FLAME INNER CONE TORCH STEM Composition of the heat. Figure 4 DEHYDRATING SEALED SYSTEM Many services feel ...into second stage which will not present a problem. Piston Type Compressor No good. TO RELATED SERVICE VALVE OR PROCESS TUBES OF THE UNIT.
Service Manual - Page 12

AF-05CML It becomes clear that good equipment and maintained properly must be used to detect leaks in order to remove air and moisture from the system. When a vacuum of moisture and no ...can be removed so that the system is free from the selector switch. (2) Using a volt-ohm-meter set on the suspect area and watching for the slightest change to green or purple when large leaks are not ...
Service Manual - Page 13

... leak and repair, recharge 13 Reading must be more than 10MΩ at DC 500V. Reading must be more than half of compressor 2) Check if temp.difference between terminals with steam cleaner or another method Remove the object or move the air conditioner Use Cooling Load Estimate Form (Refer to page 16). TROUBLESHOOTING GUIDE Symptom...
Service Manual - Page 14

...air conditioner 3) Partial restriction in sealed system 1) Check power source voltage, 1) Power source voltage too start voltage drop low 2) Wiring for power supply equipment too small With switch set...set switch contact at "Fan only" 1) Switch contact burn out 2) Switch contact defective 3) Switch cam defective 2) Check a. AF-05CML... Change motor 2) Change or repair lead wire 14 Fan capacitor...
Service Manual - Page 15

...switch" set -screws loosened 5) Fan touching 6) Insulation unstable 1) Change compressor 2) Repair or change 3) Repair 4) Tighten up fan nut is too high 1) Ventilate well for outdoor exchanger, avoid sun light, remove heat source from around outdoor unit 2) Improper ventilation for outdoor heat exchanger. is loose 3) Check the temp. Overload relay operates as outdoor air temp. AF-05CML...
Service Manual - Page 16

...estimate form is installed. B. Only one number should represent only the exposure with the NEMA Standards Publication for the particular locality as being part of any ...frame wall or a masonry wall over a basement. 6. AF-05CML COOLING LOAD ESTIMATE FORM INSTRUCTIONS FOR USING COOLING LOAD ESTIMATE FORM FOR ROOM AIR CONDITIONERS (AHAM PUB. RAC-1) A. C. For windows shades by...
Service Manual - Page 17

...above 5. FLOOR: (Disregard if floor is directly on linear feet of room air conditioner(s).) QUANTITY FACTORS DAY BTU/Hr (Quantity x Factor) No Inside Shades Shades ...Factor from sun. TOTAL COOLING LOAD: (BTU per hour to be used for selection of wall.) a. d. AF-05CML HEAT GAIN FROM 1. WINDOWS: Heat gain from Map) = EUGENE SACRAMENT RENO FRESNO LAS VEGAS PHOENIX FARGO ...
Service Manual - Page 18

... of the Running Condition of the performance curve. 3. SELECTOR ...HIGH COOL THERMOSTAT 64˚F 2. Outlet air temp. If you measure the Room Air Conditioner above or below this rating, the data may miss the range of a Room Air Conditioner. AF-05CML RUNNING CONDITION Note: 1. is measured between 40%RH and 70%RH. Data of Performance Curve is...
Service Manual - Page 19

PACKING AND ACCESSORIES TOP PAD ASSEMBLY (DPADBA004JBFZ) Top pad L Top pad R AF-05CML 4 3 5 6 6 Front side Accessories Operation manual Window sash foam seal Window sash seal Bottom gasket Screws Base pan angle Right closure assembly Left closure assembly 5 Packing case (SPAKCB001JBEZ) "Front side" mark 2 ...
Service Manual - Page 20

...Air filter Tube insulator Wire holder Wire holder Name badge Energy card Sharp badge Number card Wire fixing band Bulkhead ass'y Orifice ass'y CONTROL BOX PARTS...CODE 1 AZ 1 BB 1 BP 1 AC 1 AK 2 AE 1 AS 1 AC 1 AR 1 BK 1 AB 1 AX 1 AH 1 AU 1 AH 1 AC 3 AC 1 AC 4 AC 1 AC 2 AF... UNIT PARTS Base pan ass'y Cabinet ass'y Top inst. AF-05CML REPLACEMENT PARTS LIST ...
Service Manual - Page 21

...11 6-12 6-13 6-14 PART NO. MODEL NUMBER 2. TINSEA299JBRZ LANGAA011JBFE LANGAA012JBFE ...PARTS Operation manual...AF-05CML Q'TY CODE 1 AE 1 AH 1 AH 2 AK 1 AH 1 AE 1 AC 1 AW 1 AB 6 AA 7 AA 2 AD 1 AC 1 AC 1 AX 1 AH 1 AN 1 AP 1 AB 1 AB 4 AA 2 AA 7 AA 13 AA 6 AA 5 AA 3 AB 1 AC 4 AA 1 AB 2 AB 1 AB 1 AF 3 AC HOW TO ORDER REPLACEMENT PARTS...

Sharp AF-05CML Reviews

Do you have an experience with the Sharp AF-05CML that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Sharp yet.

Popular Sharp AF-05CML Search Terms

The following terms are frequently used to search for Sharp AF-05CML support:

Ask a New Question
Use the box below to post a new question about Sharp AF-05CML.
Manuals / Documents
Download any of our Sharp AF-05CML manuals for free!

We have the following 1 documents available for the Sharp AF-05CML:
  • Service Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp AF-05CML manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp AF-05CML user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.