Product Manual
Page 7
... 5.0 Compatibility summary 29 5.1 Installation considerations 29 5.2 BIOS versions tested 30 5.3 Operating system versions tested 30 5.4 Compatibility test configurations 31 5.5 Software utilities 31 5.6 Other certification 31 6.0 Seagate Technology support services 33 Momentus Product Manual, Rev.
... 5.0 Compatibility summary 29 5.1 Installation considerations 29 5.2 BIOS versions tested 30 5.3 Operating system versions tested 30 5.4 Compatibility test configurations 31 5.5 Software utilities 31 5.6 Other certification 31 6.0 Seagate Technology support services 33 Momentus Product Manual, Rev.
Product Manual
Page 9
Figure 3. Momentus disc drive 1 Typical 5V startup and operation current profile 9 Jumper settings 17 Mounting dimensions-top, side and end view 18 Momentus Product Manual, Rev. Figure 4. Figure 2. E vii List of Figures Figure 1.
Figure 3. Momentus disc drive 1 Typical 5V startup and operation current profile 9 Jumper settings 17 Mounting dimensions-top, side and end view 18 Momentus Product Manual, Rev. Figure 4. Figure 2. E vii List of Figures Figure 1.
Product Manual
Page 11
1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate® Momentus™ 54 drives: • ST94011A • ST94811A • ST92011A • ST92811A These drives provide the following key features: • 5,400-RPM ... disc drive Momentus Product Manual, Rev. drive monitoring and reporting. • Support for Read Multiple and Write Multiple commands. • Support for autodetection of -the-art cache and on ST94811A and ST92811A models) combine for S.M.A.R.T. Figure 1. Fluid Dynamic Bearing (FDB) motor. ...
1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate® Momentus™ 54 drives: • ST94011A • ST94811A • ST92011A • ST92811A These drives provide the following key features: • 5,400-RPM ... disc drive Momentus Product Manual, Rev. drive monitoring and reporting. • Support for Read Multiple and Write Multiple commands. • Support for autodetection of -the-art cache and on ST94811A and ST92811A models) combine for S.M.A.R.T. Figure 1. Fluid Dynamic Bearing (FDB) motor. ...
Product Manual
Page 13
... 1: Specifications Drive specification Formatted Gbytes (512 bytes/sector) Guaranteed sectors Bytes per sector Physical read ), 2.0 (write) 12.0 12.0 14.0 Momentus Product Manual, Rev. Multiword DMA modes 0-2; For convenience, the phrases the drive and this drive are used throughout this manual to -track seek... time (msec typical) Average seek time (msec typical) Average seek, read (msec typical) Average seek, write (msec typical) ST94011A ST94811A ST92011A ST92811A 40 40 20 20 78,140,160 78,140,160 39,070,080 39,070,080 512 2 2 1 1 1 1 1 1 2 ...
... 1: Specifications Drive specification Formatted Gbytes (512 bytes/sector) Guaranteed sectors Bytes per sector Physical read ), 2.0 (write) 12.0 12.0 14.0 Momentus Product Manual, Rev. Multiword DMA modes 0-2; For convenience, the phrases the drive and this drive are used throughout this manual to -track seek... time (msec typical) Average seek time (msec typical) Average seek, read (msec typical) Average seek, write (msec typical) ST94011A ST94811A ST92011A ST92811A 40 40 20 20 78,140,160 78,140,160 39,070,080 39,070,080 512 2 2 1 1 1 1 1 1 2 ...
Product Manual
Page 14
specification, which may occur according to the S.M.A.R.T. Table 1: Specifications Drive specification ST94011A ST94811A ST92011A Full-stroke seek (msec) 22 (typical); 26 (max) Seek power (typical) 2.4 watts Read/write power (typical) 2.4 watts Idle mode (typical) 1.2 watts ...of drive idle, some offline activity may increase acoustic and power to operational levels. **Typical notebooks will not contribute to battery power consumption. 4 Momentus Product Manual, Rev. while in the S3 and S4 states, drive sleep and drive standby modes will pull power to the drive when entering ...
specification, which may occur according to the S.M.A.R.T. Table 1: Specifications Drive specification ST94011A ST94811A ST92011A Full-stroke seek (msec) 22 (typical); 26 (max) Seek power (typical) 2.4 watts Read/write power (typical) 2.4 watts Idle mode (typical) 1.2 watts ...of drive idle, some offline activity may increase acoustic and power to operational levels. **Typical notebooks will not contribute to battery power consumption. 4 Momentus Product Manual, Rev. while in the S3 and S4 states, drive sleep and drive standby modes will pull power to the drive when entering ...
Product Manual
Page 15
2.2 Formatted capacity Model ST94011A ST94811A ST92011A ST92811A Formatted capacity 40 Gbytes 40 Gbytes 20 Gbytes 20 Gbytes Guaranteed sectors 78,140,160 78,140,160 39,070,080 39,070,... in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n-1, where n is the number of guaranteed sectors as defined above. 2.4 Physical organization Model ST94011A ST94811A ST92011A ST92811A Read/write heads 2 2 1 1 Number of discs 1 1 1 1 Momentus Product Manual, Rev. E 5
2.2 Formatted capacity Model ST94011A ST94811A ST92011A ST92811A Formatted capacity 40 Gbytes 40 Gbytes 20 Gbytes 20 Gbytes Guaranteed sectors 78,140,160 78,140,160 39,070,080 39,070,... in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n-1, where n is the number of guaranteed sectors as defined above. 2.4 Physical organization Model ST94011A ST94811A ST92011A ST92811A Read/write heads 2 2 1 1 Number of discs 1 1 1 1 Momentus Product Manual, Rev. E 5
Product Manual
Page 16
... rate OD (Mbytes/sec max) Sustained data transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer ST94011A and ST92011A ST94811A and ST92811A Specification Parallel ATA RLL 0,11 642,000 100,780 65 5,400 48.25 34.5 100 (Ultra DMA mode 5) 1:1 2 Mbytes (2,048 kbytes) 8 Mbytes (8,192... Width Length Typical weight (mm) (inches) (mm) (inches) (mm) (inches) (grams) (pounds) 9.5 +/-0.2 0.374 +/-0.0078 69.85 +/-0.25 2.75 +/-0.0098 100.2 +/-0.25 3.945 +/-0.0098 99 0.218 6 Momentus Product Manual, Rev. E
... rate OD (Mbytes/sec max) Sustained data transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer ST94011A and ST92011A ST94811A and ST92811A Specification Parallel ATA RLL 0,11 642,000 100,780 65 5,400 48.25 34.5 100 (Ultra DMA mode 5) 1:1 2 Mbytes (2,048 kbytes) 8 Mbytes (8,192... Width Length Typical weight (mm) (inches) (mm) (inches) (mm) (inches) (grams) (pounds) 9.5 +/-0.2 0.374 +/-0.0078 69.85 +/-0.25 2.75 +/-0.0098 100.2 +/-0.25 3.945 +/-0.0098 99 0.218 6 Momentus Product Manual, Rev. E
Product Manual
Page 17
... directions. • Average seek time is a true statistical random average of seeks between random tracks, less overhead. *Typical seek times (msec) Track-to Ready (sec) 2.6 8 Momentus Product Manual, Rev. All times are expected to meet the seek times represented in which these drives are formatted, benchmark tests that include command overhead...
... directions. • Average seek time is a true statistical random average of seeks between random tracks, less overhead. *Typical seek times (msec) Track-to Ready (sec) 2.6 8 Momentus Product Manual, Rev. All times are expected to meet the seek times represented in which these drives are formatted, benchmark tests that include command overhead...
Product Manual
Page 18
... conditions, using 40 percent random seeks, 40 percent read/write mode (1 write for the drives are active. specification, which may occur according to operational levels. 8 Momentus Product Manual, Rev. This mode is not typical. • Read/write power and current Read/write power is measured with the heads on track, based...
... conditions, using 40 percent random seeks, 40 percent read/write mode (1 write for the drives are active. specification, which may occur according to operational levels. 8 Momentus Product Manual, Rev. This mode is not typical. • Read/write power and current Read/write power is measured with the heads on track, based...
Product Manual
Page 19
... power, the drive is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% Momentus Product Manual, Rev. 2.9.1.1 Typical current profile 1.2 1.0 0.8 Amps 0.6 0.4 0.2 0.0 +5 Volt Current during spindle start - Note. Equivalent resistance is expected to operate with a maximum of 100 mV peak...
... power, the drive is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% Momentus Product Manual, Rev. 2.9.1.1 Typical current profile 1.2 1.0 0.8 Amps 0.6 0.4 0.2 0.0 +5 Volt Current during spindle start - Note. Equivalent resistance is expected to operate with a maximum of 100 mV peak...
Product Manual
Page 20
... power management through the system setup program. In Standby mode, the drive buffer is enabled, the heads are parked and the spindle is necessary. 10 Momentus Product Manual, Rev. If the standby timer reaches zero before any drive activity is at rest. In most systems, you can also enter Standby mode...
... power management through the system setup program. In Standby mode, the drive buffer is enabled, the heads are parked and the spindle is necessary. 10 Momentus Product Manual, Rev. If the standby timer reaches zero before any drive activity is at rest. In most systems, you can also enter Standby mode...
Product Manual
Page 21
...;F max) 2.10.4 Altitude Operating -198.12 m to 3,048 m (-650 ft to 10,000+ ft) Nonoperating -304.8 to 12,192 m (-1,000 ft to 40,000+ ft) Momentus Product Manual, Rev.
...;F max) 2.10.4 Altitude Operating -198.12 m to 3,048 m (-650 ft to 10,000+ ft) Nonoperating -304.8 to 12,192 m (-1,000 ft to 40,000+ ft) Momentus Product Manual, Rev.
Product Manual
Page 22
... 800 Gs based on a nonrepetitive half-sine shock pulse of 1 msec duration. The nonoperating shock level that the drive may apply below 22 Hz. 12 Momentus Product Manual, Rev. E Max displacement may experience while meeting the performance standards specified in this document. 5-500 Hz 1.0 Gs (0 to peak).
... 800 Gs based on a nonrepetitive half-sine shock pulse of 1 msec duration. The nonoperating shock level that the drive may apply below 22 Hz. 12 Momentus Product Manual, Rev. E Max displacement may experience while meeting the performance standards specified in this document. 5-500 Hz 1.0 Gs (0 to peak).
Product Manual
Page 23
... seconds B Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94 Momentus Product Manual, Rev. For all tests, the drive is defined by the following table: Table 5: Electromagnetic immunity Test Electrostatic discharge Radiated RF immunity Electrical fast...
... seconds B Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94 Momentus Product Manual, Rev. For all tests, the drive is defined by the following table: Table 5: Electromagnetic immunity Test Electrostatic discharge Radiated RF immunity Electrical fast...
Product Manual
Page 24
... by TUV North America. 2.14.2 Electromagnetic compatibility Hard drives that all systems will comply with properly shielded I /O ports. Seagate uses an independent laboratory to the levels specified by EN 55024. E Drives are defined by the product standards for Information Technology...and provide CE marking for operation inside a properly designed enclosure, with the directives. Testing is designed for their products. 14 Momentus Product Manual, Rev. 2.13 Reliability Measurement type Nonrecoverable read errors Mean time between failures Load/Unload (U/UL) 25°C, ...
... by TUV North America. 2.14.2 Electromagnetic compatibility Hard drives that all systems will comply with properly shielded I /O ports. Seagate uses an independent laboratory to the levels specified by EN 55024. E Drives are defined by the product standards for Information Technology...and provide CE marking for operation inside a properly designed enclosure, with the directives. Testing is designed for their products. 14 Momentus Product Manual, Rev. 2.13 Reliability Measurement type Nonrecoverable read errors Mean time between failures Load/Unload (U/UL) 25°C, ...
Product Manual
Page 25
... customer. ST92011A, ST94811A and ST92811A • Certificate numbers: ST94011A ST92011A ST94811A ST92811A E-H011-03-1191(B) E-H011-03-1192(B) E-H011-03-1189(B) E-H011-03-1190(B) • Trade name or applicant: Seagate Technology • ...Manufacturing date: April 2003 • Manufacturer/nationality: USA, Singapore and China Australian C-Tick (N176) If these drives have the Korea Ministry of Information and Communication (MIC) logo, they comply with the manufacturer's instructions, may cause interference to radio and television reception. Momentus...
... customer. ST92011A, ST94811A and ST92811A • Certificate numbers: ST94011A ST92011A ST94811A ST92811A E-H011-03-1191(B) E-H011-03-1192(B) E-H011-03-1189(B) E-H011-03-1190(B) • Trade name or applicant: Seagate Technology • ...Manufacturing date: April 2003 • Manufacturer/nationality: USA, Singapore and China Australian C-Tick (N176) If these drives have the Korea Ministry of Information and Communication (MIC) logo, they comply with the manufacturer's instructions, may cause interference to radio and television reception. Momentus...
Product Manual
Page 26
Refer to Identify and Resolve Radio-Television Interference Problems. This booklet is available from the Superintendent of Documents, U.S. E You may find helpful the following booklet prepared by the Federal Communications Commission: How to publication number 004-000-00345-4. 16 Momentus Product Manual, Rev. If necessary, you should consult your dealer or an experienced radio/television technician for additional suggestions. Government Printing Office, Washington, DC 20402.
Refer to Identify and Resolve Radio-Television Interference Problems. This booklet is available from the Superintendent of Documents, U.S. E You may find helpful the following booklet prepared by the Federal Communications Commission: How to publication number 004-000-00345-4. 16 Momentus Product Manual, Rev. If necessary, you should consult your dealer or an experienced radio/television technician for additional suggestions. Government Printing Office, Washington, DC 20402.
Product Manual
Page 27
... to potential handling and electrostatic discharge (ESD) hazards. Removal voids the warranty. For additional information about using the Cable select option, see section 3.2.2. Jumper settings Momentus Product Manual, Rev. Some factory-installed labels contain information needed to pins 1 and 2 of a computer that is plugged into a grounded outlet. Do not press down...
... to potential handling and electrostatic discharge (ESD) hazards. Removal voids the warranty. For additional information about using the Cable select option, see section 3.2.2. Jumper settings Momentus Product Manual, Rev. Some factory-installed labels contain information needed to pins 1 and 2 of a computer that is plugged into a grounded outlet. Do not press down...
Product Manual
Page 28
... select determine the master and slave drives by their physical position on the interface bus. Mounting dimensions-top, side and end view 18 .160 (4.06) Momentus Product Manual, Rev. Master and slave drives are determined by selecting or deselecting pin 28, CSEL, on the cable. full thread 4X M3 X 0.5-6H Mounting...
... select determine the master and slave drives by their physical position on the interface bus. Mounting dimensions-top, side and end view 18 .160 (4.06) Momentus Product Manual, Rev. Master and slave drives are determined by selecting or deselecting pin 28, CSEL, on the cable. full thread 4X M3 X 0.5-6H Mounting...
Product Manual
Page 29
... 44 Signal Name Ground DD8 DD9 DD10 DD11 DD12 DD13 DD14 DD15 (keypin) Ground Ground Ground PSYNC:CSEL Ground IOCS16PDIAGDA2 CS3FXGround +5V (Motor) No connection Momentus Product Manual, Rev.
... 44 Signal Name Ground DD8 DD9 DD10 DD11 DD12 DD13 DD14 DD15 (keypin) Ground Ground Ground PSYNC:CSEL Ground IOCS16PDIAGDA2 CS3FXGround +5V (Motor) No connection Momentus Product Manual, Rev.