Pulsar.2 SAS Product Manual
Page 3
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
Pulsar.2 SAS Product Manual
Page 4
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize - B Cryptographic Erase ...9.11 RevertSP ...9.12 Sanitize Feature Set on SED Drives ...Defect and error management ...10.1 Drive internal defects/errors ...10.2 Drive...
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize - B Cryptographic Erase ...9.11 RevertSP ...9.12 Sanitize Feature Set on SED Drives ...Defect and error management ...10.1 Drive internal defects/errors ...10.2 Drive...
Pulsar.2 SAS Product Manual
Page 9
..." or "Usage Based". Consult your Seagate sales representative for warranty terms and conditions. 1.0 Seagate Technology support services SEAGATE ONLINE SUPPORT and SERVICES For information regarding Data Recovery Services, visit http://www.i365.com For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system For Seagate reseller portal, visit http://spp.seagate.com Pulsar.2 SAS Product Manual...
..." or "Usage Based". Consult your Seagate sales representative for warranty terms and conditions. 1.0 Seagate Technology support services SEAGATE ONLINE SUPPORT and SERVICES For information regarding Data Recovery Services, visit http://www.i365.com For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system For Seagate reseller portal, visit http://spp.seagate.com Pulsar.2 SAS Product Manual...
Pulsar.2 SAS Product Manual
Page 10
...the cover of this manual is specific only to the model numbers listed in Section 1.0. Note. Standard models ST800FM0002 ST800FM0032 ST400FM0002 ST400FM0042 ST200FM0002 ST200FM0042 ST100FM0002 ST100FM0052 Standard SED models ST800FM0012 ST800FM0042 FIPS 140-2 Level 2 (Review Pending) ST800FM0022 Note. Product ...products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this and other forms of Seagate Self-Encrypting Drive models were called Full Disk Encryption (FDE) models before a differentiation between...
...the cover of this manual is specific only to the model numbers listed in Section 1.0. Note. Standard models ST800FM0002 ST800FM0032 ST400FM0002 ST400FM0042 ST200FM0002 ST200FM0042 ST100FM0002 ST100FM0052 Standard SED models ST800FM0012 ST800FM0042 FIPS 140-2 Level 2 (Review Pending) ST800FM0022 Note. Product ...products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this and other forms of Seagate Self-Encrypting Drive models were called Full Disk Encryption (FDE) models before a differentiation between...
Pulsar.2 SAS Product Manual
Page 14
...manual have the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for SAS expanders and fanout adapters Firmware downloadable using the SAS interface 128 - The Serial Attached SCSI interface is applied to meet ... future users the choice of Data at Rest" based on certain models) 6 Pulsar.2 SAS Product Manual, Rev. deep task set (queue) Supports up to 32 initiators Jumperless configuration User-selectable logical block size (512, 520, 524, 528, 4096, 4160, 4192, or 4224 bytes per...
...manual have the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for SAS expanders and fanout adapters Firmware downloadable using the SAS interface 128 - The Serial Attached SCSI interface is applied to meet ... future users the choice of Data at Rest" based on certain models) 6 Pulsar.2 SAS Product Manual, Rev. deep task set (queue) Supports up to 32 initiators Jumperless configuration User-selectable logical block size (512, 520, 524, 528, 4096, 4160, 4192, or 4224 bytes per...
Pulsar.2 SAS Product Manual
Page 17
... allocates Logical Blocks Addresses that are defined as needed. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to one indicates that, for an unmapped LBA specified by a...if Thin Provisioning is a major factor in SSD products because it are allowed to zero indicates that is defined in the Seagate SCSI Command Reference 100293068.. A logical block provisioning read zeros (LBPRZ) bit set to any device which does not require Logical...
... allocates Logical Blocks Addresses that are defined as needed. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to one indicates that, for an unmapped LBA specified by a...if Thin Provisioning is a major factor in SSD products because it are allowed to zero indicates that is defined in the Seagate SCSI Command Reference 100293068.. A logical block provisioning read zeros (LBPRZ) bit set to any device which does not require Logical...
Pulsar.2 SAS Product Manual
Page 21
Intel does not endorse any IOMeter results. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that the product will be able to achieve...performance is defined as mentioned and host commands are aligned on 4KB boundaries. 5.2.3 Table 6: Performance Performance (Managed Life Warranty) Notes ST800FM0002 ST800FM0012 ST800FM0022 ST400FM0002 ST200FM0002 ST100FM0002 Maximum Burst Transfer Rate Peak sequential 128KB read/write data transfer rate (MB/s max) Sustained sequential 128KB read/ write data transfer rate (...
Intel does not endorse any IOMeter results. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that the product will be able to achieve...performance is defined as mentioned and host commands are aligned on 4KB boundaries. 5.2.3 Table 6: Performance Performance (Managed Life Warranty) Notes ST800FM0002 ST800FM0012 ST800FM0022 ST400FM0002 ST200FM0002 ST100FM0002 Maximum Burst Transfer Rate Peak sequential 128KB read/write data transfer rate (MB/s max) Sustained sequential 128KB read/ write data transfer rate (...
Pulsar.2 SAS Product Manual
Page 31
.... Drives should be stored in handling computer equipment. B 23 Usage Based Warranty This warranty is 30 days. Contact your Seagate sales representative for warranty terms and conditions. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for the drive in a non-operational environment is term based and includes the Lifetime Endurance Management feature stated...
.... Drives should be stored in handling computer equipment. B 23 Usage Based Warranty This warranty is 30 days. Contact your Seagate sales representative for warranty terms and conditions. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for the drive in a non-operational environment is term based and includes the Lifetime Endurance Management feature stated...
Pulsar.2 SAS Product Manual
Page 52
...erases all SPs (Security Providers) on the device to their original factory state. Three conditions must be provided. OEM drives shall support the command. 44 Pulsar.2 SAS Product Manual, Rev. The download must pass the acceptance criteria for power requirements on the standard... (non-SED) drive models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. For example it with a non-SED drive, the download file must be...
...erases all SPs (Security Providers) on the device to their original factory state. Three conditions must be provided. OEM drives shall support the command. 44 Pulsar.2 SAS Product Manual, Rev. The download must pass the acceptance criteria for power requirements on the standard... (non-SED) drive models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. For example it with a non-SED drive, the download file must be...
Pulsar.2 SAS Product Manual
Page 53
...locations recorded on the drive primary defects list (referred to manage defects and errors. The definition of the SCSI commands supported by the initiator using the READ DEFECT DATA command. B 45 SCSI defect and error management involves drive internal defect/error... management and SAS system error considerations (errors in the SAS Interface Manual. In addition, Seagate provides the following table. Details of the 110b format is defined in the SAS Interface Manual. Table 13: Bit Byte 0 1 2 3 ...
...locations recorded on the drive primary defects list (referred to manage defects and errors. The definition of the SCSI commands supported by the initiator using the READ DEFECT DATA command. B 45 SCSI defect and error management involves drive internal defect/error... management and SAS system error considerations (errors in the SAS Interface Manual. In addition, Seagate provides the following table. Details of the 110b format is defined in the SAS Interface Manual. Table 13: Bit Byte 0 1 2 3 ...
Pulsar.2 SAS Product Manual
Page 55
...can only be transferred to the host during a READ command. Vital Product Descriptor (VPD) page 0x86 provides bits to indicate the PI Types supported and which it . B 47 same capacity point) as part of the data transferred to integrate this level of PI by using the FORMAT...due to the extra overhead of PI protection using 520 byte formatted LBAs. Provides support of PI being transferred from the media that typically does not support 520 LBA formats to the host. Type 3 - Seagate products do not support Type 3. 10.6.2 Setting and determining the current Type Level A drive is ...
...can only be transferred to the host during a READ command. Vital Product Descriptor (VPD) page 0x86 provides bits to indicate the PI Types supported and which it . B 47 same capacity point) as part of the data transferred to integrate this level of PI by using the FORMAT...due to the extra overhead of PI protection using 520 byte formatted LBAs. Provides support of PI being transferred from the media that typically does not support 520 LBA formats to the host. Type 3 - Seagate products do not support Type 3. 10.6.2 Setting and determining the current Type Level A drive is ...
Pulsar.2 SAS Product Manual
Page 59
... 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. B 51 Table 14: Task name Abort Task Abort task set Clear ...ACA Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for task management...
... 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. B 51 Table 14: Task name Abort Task Abort task set Clear ...ACA Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for task management...
Pulsar.2 SAS Product Manual
Page 60
...two independent ports. Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. 12.2 Dual port support Pulsar.2 SAS drives have the capability of independent port clocking ...first port can run at 6Gb/s while the second port runs at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. 52 Pulsar.2 SAS Product Manual, Rev.
...two independent ports. Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. 12.2 Dual port support Pulsar.2 SAS drives have the capability of independent port clocking ...first port can run at 6Gb/s while the second port runs at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports. 52 Pulsar.2 SAS Product Manual, Rev.
Pulsar.2 SAS Product Manual
Page 61
... 16 lists the SCSI commands supported by Pulsar.2 drives. B 53 Table 16: Supported commands Command code Supported Command name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (B0h... page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page...
... 16 lists the SCSI commands supported by Pulsar.2 drives. B 53 Table 16: Supported commands Command code Supported Command name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (B0h... page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page...
Pulsar.2 SAS Product Manual
Page 62
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
Pulsar.2 SAS Product Manual
Page 63
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
Pulsar.2 SAS Product Manual
Page 64
... 4096, 4160, 4192 and 4224 bytes per logical block. Reference MODE SENSE command 1Ah for mode pages supported. N = No. Warning. A = Support is supported. Y = Yes. B Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY (32) WRITE (6) WRITE...32) WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG (16...
... 4096, 4160, 4192 and 4224 bytes per logical block. Reference MODE SENSE command 1Ah for mode pages supported. N = No. Warning. A = Support is supported. Y = Yes. B Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY (32) WRITE (6) WRITE...32) WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG (16...
Pulsar.2 SAS Product Manual
Page 65
... of bytes 16 through 26 reflect model of the product firmware release number. Four ASCII digits representing the last four digits of drive. SCSI Revision support. The table above shows the hex values for an INQUIRY command received on Port B. 12.3.1 INQUIRY data Table 17 lists the INQUIRY command data that... 32 ST800FM0032 53 54 38 30 30 46 4D 30 30 33 32 ST800FM0042 53 54 38 30 30 46 4D 30 30 34 32 ST400FM0002 53 54 34 30 30 46 4D 30 30 30 32 ST400FM0042 53 54 34 30 30 46 4D 30 30 34 32 ST200FM0002 53...
... of bytes 16 through 26 reflect model of the product firmware release number. Four ASCII digits representing the last four digits of drive. SCSI Revision support. The table above shows the hex values for an INQUIRY command received on Port B. 12.3.1 INQUIRY data Table 17 lists the INQUIRY command data that... 32 ST800FM0032 53 54 38 30 30 46 4D 30 30 33 32 ST800FM0042 53 54 38 30 30 46 4D 30 30 34 32 ST400FM0002 53 54 34 30 30 46 4D 30 30 30 32 ST400FM0042 53 54 34 30 30 46 4D 30 30 34 32 ST200FM0002 53...
Pulsar.2 SAS Product Manual
Page 71
... ACA active, faulted initiator Task Aborted 12.4.1 SAS physical interface Figure 17 shows the location of Seagate's SAS drives are provided within this section. The operational aspects of the SAS device connector J1. Table 22: Supported N N Y N Y Y Y N Miscellaneous features Feature or condition Automatic contingent allegiance Asynchronous event notification Segmented caching Zero latency read...
... ACA active, faulted initiator Task Aborted 12.4.1 SAS physical interface Figure 17 shows the location of Seagate's SAS drives are provided within this section. The operational aspects of the SAS device connector J1. Table 22: Supported N N Y N Y Y Y N Miscellaneous features Feature or condition Automatic contingent allegiance Asynchronous event notification Segmented caching Zero latency read...
Pulsar.2 SAS Product Manual
Page 74
... +Port A_out Port A Ground Port B Ground +Port B_in -Port B_in Port A Ground -Port B_out +Port B_out Port B Ground * - The SAS device connector is designed to support hot plugging NC - 12.4.2 Physical characteristics This section defines physical interface connector. 12.4.3 Connector requirements Contact your preferred connector manufacturer for : • DC power •...
... +Port A_out Port A Ground Port B Ground +Port B_in -Port B_in Port A Ground -Port B_out +Port B_out Port B Ground * - The SAS device connector is designed to support hot plugging NC - 12.4.2 Physical characteristics This section defines physical interface connector. 12.4.3 Connector requirements Contact your preferred connector manufacturer for : • DC power •...