Momentus 7200 FDE.2 SATA Product Manual
Page 3
... Restriction of Hazardous Substances (RoHS) Directive 18 2.16 Corrosive environment 18 3.0 Configuring and mounting the drive 19 3.1 Handling and static-discharge precautions 19 3.2 Configuring the drive 20 3.3 Serial ATA cables and connectors 20 3.4 Drive mounting 21 3.5 Drive integration 22 3.5.1 Drive installation 23 3.5.2 Consumer usage 23 3.6 Security Erase--ATA security commands 23 3.6.1 Secure Erase procedure 23...
... Restriction of Hazardous Substances (RoHS) Directive 18 2.16 Corrosive environment 18 3.0 Configuring and mounting the drive 19 3.1 Handling and static-discharge precautions 19 3.2 Configuring the drive 20 3.3 Serial ATA cables and connectors 20 3.4 Drive mounting 21 3.5 Drive integration 22 3.5.1 Drive installation 23 3.5.2 Consumer usage 23 3.6 Security Erase--ATA security commands 23 3.6.1 Secure Erase procedure 23...
Momentus 7200 FDE.2 SATA Product Manual
Page 5
List of Figures Figure 1. Figure 4. Figure 2. Figure 5. Typical +5V only startup and operation current profile 10 Serial ATA connectors 20 Attaching SATA cabling 20 Mounting dimensions 21 Momentus 7200 FDE.2 SATA drive label example 22 Momentus 7200 FDE.2 SATA Product Manual, Rev. Figure 3. B iii
List of Figures Figure 1. Figure 4. Figure 2. Figure 5. Typical +5V only startup and operation current profile 10 Serial ATA connectors 20 Attaching SATA cabling 20 Mounting dimensions 21 Momentus 7200 FDE.2 SATA drive label example 22 Momentus 7200 FDE.2 SATA Product Manual, Rev. Figure 3. B iii
Momentus 7200 FDE.2 SATA Product Manual
Page 7
...S.M.A.R.T. 1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate Momentus® 7200 FDE.2 SATA model drives: Standard Models FIPS 140-2 Pending Models Standard models ST9500421AS ST9320426AS ST9250411AS ST9160413AS Free Fall ...ST9500426ASG ST9320426ASG ST9250464ASG ST9160418ASG Standard models ST9500422AS ST9250412AS Free Fall Sensor models ST9320427ASG ST9250414ASG ST9160419ASG These drives provide the following models are in-process for FIPS 140-2 validation (Certification Pending): ST9500422AS, ST9320427ASG, ST9250414ASG, ...
...S.M.A.R.T. 1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate Momentus® 7200 FDE.2 SATA model drives: Standard Models FIPS 140-2 Pending Models Standard models ST9500421AS ST9320426AS ST9250411AS ST9160413AS Free Fall ...ST9500426ASG ST9320426ASG ST9250464ASG ST9160418ASG Standard models ST9500422AS ST9250412AS Free Fall Sensor models ST9320427ASG ST9250414ASG ST9160419ASG These drives provide the following models are in-process for FIPS 140-2 validation (Certification Pending): ST9500422AS, ST9320427ASG, ST9250414ASG, ...
Momentus 7200 FDE.2 SATA Product Manual
Page 8
...: • Windows XP with no measurable performance loss • All user data is encrypted on write operations and decrypted on the drive • Operations are performed with Service Pack 2 (or later) when utilizing the Windows DriveTrust API. • System/BIOS that ... will need a host system and operating system that supports ATA Security commands. 1.2 About Momentus 7200 FDE.2 SATA disc drives Momentus® 7200 FDE.2 SATA drives contain DriveTrust technology providing Full Disc Encryption (FDE) using proven Advanced Encryption Standard (AES) data encryption and decryption. ...
...: • Windows XP with no measurable performance loss • All user data is encrypted on write operations and decrypted on the drive • Operations are performed with Service Pack 2 (or later) when utilizing the Windows DriveTrust API. • System/BIOS that ... will need a host system and operating system that supports ATA Security commands. 1.2 About Momentus 7200 FDE.2 SATA disc drives Momentus® 7200 FDE.2 SATA drives contain DriveTrust technology providing Full Disc Encryption (FDE) using proven Advanced Encryption Standard (AES) data encryption and decryption. ...
Momentus 7200 FDE.2 SATA Product Manual
Page 9
...8226; ATA Security is enabled and operational when the drive leaves the Seagate factory. The purpose of full disc encryption on the drive is to access the drive, so the data on the drive in the same way you would integrate a non-FDE Momentus drive. This data at the SATA interface speed. The system... user password is null (no value). • The ATA master password is set to anyone possessing the drive. The encryption and decryption is done on powerup and when awakening from the Seagate factory, the ATA Security Interface is lost or stolen, their system is lost or stolen. It is ...
...8226; ATA Security is enabled and operational when the drive leaves the Seagate factory. The purpose of full disc encryption on the drive is to access the drive, so the data on the drive in the same way you would integrate a non-FDE Momentus drive. This data at the SATA interface speed. The system... user password is null (no value). • The ATA master password is set to anyone possessing the drive. The encryption and decryption is done on powerup and when awakening from the Seagate factory, the ATA Security Interface is lost or stolen, their system is lost or stolen. It is ...
Momentus 7200 FDE.2 SATA Product Manual
Page 10
Table 2: Drive specifications Drive specification ST9500426ASG ST9500422AS ST9500421AS ST9320427ASG ST9320426ASG ST9320426AS ST9250464ASG ST9250414ASG ST9250412AS ST9250411AS Formatted Gbytes (512 bytes/sector)* 500 320 250 ... +5V (max) 1.0 amps ST9160419ASG ST9160418ASG ST9160413AS 160 312,581,808 2 1 105 grams (0.227 lb) 4 Momentus 7200 FDE.2 SATA Product Manual, Rev. B 2.0 Drive specifications Unless otherwise noted, all specifications are measured under ambient conditions, at 25°C, and nominal power. 2.1 Specification summary table The specifications listed in BPI...
Table 2: Drive specifications Drive specification ST9500426ASG ST9500422AS ST9500421AS ST9320427ASG ST9320426ASG ST9320426AS ST9250464ASG ST9250414ASG ST9250412AS ST9250411AS Formatted Gbytes (512 bytes/sector)* 500 320 250 ... +5V (max) 1.0 amps ST9160419ASG ST9160418ASG ST9160413AS 160 312,581,808 2 1 105 grams (0.227 lb) 4 Momentus 7200 FDE.2 SATA Product Manual, Rev. B 2.0 Drive specifications Unless otherwise noted, all specifications are measured under ambient conditions, at 25°C, and nominal power. 2.1 Specification summary table The specifications listed in BPI...
Momentus 7200 FDE.2 SATA Product Manual
Page 11
...max at 2 msec) Shock, nonoperating (Gs max at 1 msec) Shock, nonoperating (Gs max at 0.5 msec) Vibration, operating Vibration, nonoperating Drive acoustics, sound power (bels) Idle** Performance seek Nonrecoverable read errors Annualized Failure Rate (AFR) Load/Unload (U/UL) cycles 25°C, 50% ...warranty for your drive. After submitting this information, the system will be asked to access the following web page: support.seagate.com/customer/warranty_validation.jsp You will display the warranty information for a specific drive, use a web browser to provide the drive serial number, ...
...max at 2 msec) Shock, nonoperating (Gs max at 1 msec) Shock, nonoperating (Gs max at 0.5 msec) Vibration, operating Vibration, nonoperating Drive acoustics, sound power (bels) Idle** Performance seek Nonrecoverable read errors Annualized Failure Rate (AFR) Load/Unload (U/UL) cycles 25°C, 50% ...warranty for your drive. After submitting this information, the system will be asked to access the following web page: support.seagate.com/customer/warranty_validation.jsp You will display the warranty information for a specific drive, use a web browser to provide the drive serial number, ...
Momentus 7200 FDE.2 SATA Product Manual
Page 12
...one billion bytes when referring to n-1, where n is the number of guaranteed sectors as defined above . 2.4 Physical organization Drive model ST9500426ASG, ST9500422AS and ST9500421AS ST9320427ASG, ST9320426ASG and ST9320426AS ST9250464ASG, ST9250414ASG, ST9250412AS and ST9250411AS ST9160419ASG, ST9160418ASG and ST9160413AS Read/...Rev. Accessible capacity may vary depending on operating environment and formatting. **During periods of drive idle, some offline activity may occur according to the drive when entering S3 and S4; while in LBA mode, all blocks (sectors) are consecutively...
...one billion bytes when referring to n-1, where n is the number of guaranteed sectors as defined above . 2.4 Physical organization Drive model ST9500426ASG, ST9500422AS and ST9500421AS ST9320427ASG, ST9320426ASG and ST9320426AS ST9250464ASG, ST9250414ASG, ST9250412AS and ST9250411AS ST9160419ASG, ST9160418ASG and ST9160413AS Read/...Rev. Accessible capacity may vary depending on operating environment and formatting. **During periods of drive idle, some offline activity may occur according to the drive when entering S3 and S4; while in LBA mode, all blocks (sectors) are consecutively...
Momentus 7200 FDE.2 SATA Product Manual
Page 13
... rate (Gbits/sec) I/O data-transfer rate (Gbits/sec max) Interleave Cache buffer Serial ATA (SATA) Perpendicular 1,490k 265k 394 7,200 1.23 3.0 1:1 16 Mbytes 2.6 Physical characteristics Drive specification Height (mm) (inches) Width (mm) (inches) Length (mm) (inches) Typical weight ST9500426ASG, ST9500422AS, ST9500421AS ST9320427ASG, ST9320426ASG, ST9320426AS ST9250464ASG, ST9250414ASG, ST9250412AS and ST9250411AS 9.4 +/-0.2 0.371 +/-0.008...
... rate (Gbits/sec) I/O data-transfer rate (Gbits/sec max) Interleave Cache buffer Serial ATA (SATA) Perpendicular 1,490k 265k 394 7,200 1.23 3.0 1:1 16 Mbytes 2.6 Physical characteristics Drive specification Height (mm) (inches) Width (mm) (inches) Length (mm) (inches) Typical weight ST9500426ASG, ST9500422AS, ST9500421AS ST9320427ASG, ST9320426ASG, ST9320426AS ST9250464ASG, ST9250414ASG, ST9250412AS and ST9250411AS 9.4 +/-0.2 0.371 +/-0.008...
Momentus 7200 FDE.2 SATA Product Manual
Page 14
...times are taken with nominal power at least 5,000 measurements of seeks between random tracks, less overhead. 2.7 Seek time Seek measurements are measured using drive diagnostics. B However, due to the manner in which these specifications. 2.8 Start/stop times Time to ready Power-on to Ready (sec) Standby... to Ready (sec) Typical 4.5 3.0 Max @ 25°C 5.0 3.5 8 Momentus 7200 FDE.2 SATA Product Manual, Rev. These drives are formatted, benchmark tests that include command overhead or measure logical seeks may produce results that vary from these...
...times are taken with nominal power at least 5,000 measurements of seeks between random tracks, less overhead. 2.7 Seek time Seek measurements are measured using drive diagnostics. B However, due to the manner in which these specifications. 2.8 Start/stop times Time to ready Power-on to Ready (sec) Standby... to Ready (sec) Typical 4.5 3.0 Max @ 25°C 5.0 3.5 8 Momentus 7200 FDE.2 SATA Product Manual, Rev. These drives are formatted, benchmark tests that include command overhead or measure logical seeks may produce results that vary from these...
Momentus 7200 FDE.2 SATA Product Manual
Page 15
..., based on three 63 sector read or write operations every 100 msecs. • Idle mode power Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location. • Standby mode During Standby mode, the...*During periods of power-on to the S.M.A.R.T. Momentus 7200 FDE.2 SATA Product Manual, Rev. specification, which may occur according to the time that the drive spindle reaches operating speed. • Seek mode During seek mode, the read/write actuator arm moves toward a specific position on the disc surface and does...
..., based on three 63 sector read or write operations every 100 msecs. • Idle mode power Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location. • Standby mode During Standby mode, the...*During periods of power-on to the S.M.A.R.T. Momentus 7200 FDE.2 SATA Product Manual, Rev. specification, which may occur according to the time that the drive spindle reaches operating speed. • Seek mode During seek mode, the read/write actuator arm moves toward a specific position on the disc surface and does...
Momentus 7200 FDE.2 SATA Product Manual
Page 16
... at the host system power supply across an equivalent 15-ohm resistive load on the +5 volt line. 2.9.1.1 Typical current profile Figure 1. Using 5-volt power, the drive is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% 10 Momentus 7200...
... at the host system power supply across an equivalent 15-ohm resistive load on the +5 volt line. 2.9.1.1 Typical current profile Figure 1. Using 5-volt power, the drive is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% 10 Momentus 7200...
Momentus 7200 FDE.2 SATA Product Manual
Page 17
... power Self refresh-low power Self refresh-low power Self refresh-low power Self refresh-low power Self refresh-low power • Active mode The drive is in Active mode during the read/write and seek operations. • Idle mode The buffer remains enabled, and the... delay times to Active mode any time disc access is reinitialized and begins counting down from the host. In both Idle and Standby mode, the drive accepts all commands and returns to zero. Momentus 7200 FDE.2 SATA Product Manual, Rev. If the standby timer reaches zero before any time disc access...
... power Self refresh-low power Self refresh-low power Self refresh-low power Self refresh-low power Self refresh-low power • Active mode The drive is in Active mode during the read/write and seek operations. • Idle mode The buffer remains enabled, and the... delay times to Active mode any time disc access is reinitialized and begins counting down from the host. In both Idle and Standby mode, the drive accepts all commands and returns to zero. Momentus 7200 FDE.2 SATA Product Manual, Rev. If the standby timer reaches zero before any time disc access...
Momentus 7200 FDE.2 SATA Product Manual
Page 18
...°F) within the operating ambient conditions. B Above 1,000 feet (305 meters), the maximum temperature is defined as the temperature of the environment immediately surrounding the drive. 2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is derated linearly by 1°C every 1000 feet. Operating Nonoperating 0° to 60°C (32° to...
...°F) within the operating ambient conditions. B Above 1,000 feet (305 meters), the maximum temperature is defined as the temperature of the environment immediately surrounding the drive. 2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is derated linearly by 1°C every 1000 feet. Operating Nonoperating 0° to 60°C (32° to...
Momentus 7200 FDE.2 SATA Product Manual
Page 19
...is 600 Gs based on a nonrepetitive half-sine shock pulse of 0.5 msec duration. 2.10.6 Vibration All vibration specifications assume that the drive is 1,000 Gs based on a nonrepetitive half-sine shock pulse of 1 msec duration. Max displacement may experience without incurring physical damage or...shock of 350 Gs based on half-sine shock pulses of 2 msec. 2.10.5.2 Nonoperating shock The nonoperating shock level that the drive can experience without incurring physical damage or degradation in this document when subjected to peak). 2.10.5 Shock All shock specifications assume that the...
...is 600 Gs based on a nonrepetitive half-sine shock pulse of 0.5 msec duration. 2.10.6 Vibration All vibration specifications assume that the drive is 1,000 Gs based on a nonrepetitive half-sine shock pulse of 1 msec duration. Max displacement may experience without incurring physical damage or...shock of 350 Gs based on half-sine shock pulses of 2 msec. 2.10.5.2 Nonoperating shock The nonoperating shock level that the drive can experience without incurring physical damage or degradation in this document when subjected to peak). 2.10.5 Shock All shock specifications assume that the...
Momentus 7200 FDE.2 SATA Product Manual
Page 20
...installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: 14 Momentus 7200 FDE.2 SATA Product Manual, Rev. Seagate uses the lower limit for the threshold ...During periods of hearing. Testing is the use of the absolute threshold of drive idle, some offline activity may increase acoustic and power to the S.M.A.R.T. Test for Prominent Discrete Tones (PDTs) Seagate follows the ECMA-74 standards for measurement and identification of sound is measured ...
...installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: 14 Momentus 7200 FDE.2 SATA Product Manual, Rev. Seagate uses the lower limit for the threshold ...During periods of hearing. Testing is the use of the absolute threshold of drive idle, some offline activity may increase acoustic and power to the S.M.A.R.T. Test for Prominent Discrete Tones (PDTs) Seagate follows the ECMA-74 standards for measurement and identification of sound is measured ...
Momentus 7200 FDE.2 SATA Product Manual
Page 21
... web page: support.seagate.com/customer/warranty_validation.jsp You will display the warranty information for warranty support, if possible, you should provide the valid ATA Master password, or return the drive in the Security Erased...177; 1 kV differential, ± 2 kV common, AC mains B 150 kHz to provide the drive serial number, model number (or part number) and country of purchase. Test Electrostatic discharge Radiated RF immunity... the User Data Area accessible. If these recommendations are not followed, Seagate cannot access the drive to perform failure analysis to verify your...
... web page: support.seagate.com/customer/warranty_validation.jsp You will display the warranty information for warranty support, if possible, you should provide the valid ATA Master password, or return the drive in the Security Erased...177; 1 kV differential, ± 2 kV common, AC mains B 150 kHz to provide the drive serial number, model number (or part number) and country of purchase. Test Electrostatic discharge Radiated RF immunity... the User Data Area accessible. If these recommendations are not followed, Seagate cannot access the drive to perform failure analysis to verify your...
Momentus 7200 FDE.2 SATA Product Manual
Page 22
...B and the immunity levels are recognized in the Electromagnetic Compatibility Directive (2004/108/EEC). Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the test systems, we cannot guarantee that display the...inches (nominal). Momentus 72004 (B) • Trade name or applicant: Seagate Technology LLC • Manufacturing date: October 30, 2008 • Manufacturer/nationality: USA and China Australian C-Tick (N176) If these drives have the C-Tick marking, they comply with the Australia/New Zealand Standard...
...B and the immunity levels are recognized in the Electromagnetic Compatibility Directive (2004/108/EEC). Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the test systems, we cannot guarantee that display the...inches (nominal). Momentus 72004 (B) • Trade name or applicant: Seagate Technology LLC • Manufacturing date: October 30, 2008 • Manufacturer/nationality: USA and China Australian C-Tick (N176) If these drives have the C-Tick marking, they comply with the Australia/New Zealand Standard...
Momentus 7200 FDE.2 SATA Product Manual
Page 23
...installation. If this device in electronic products, effective July 2006. This drive is no Federal Communications Commission verification or certification of Hazardous Substances (RoHS) Seagate designs its products to Identify and Resolve Radio-Television Interference Problems. ... interference will not occur in a residential installation. Refer to publication number 004-000-00345-4. 2.15 Environmental protection Seagate designs its products to meet environmental protection requirements worldwide, including regulations restricting certain chemical substances. Momentus 7200 FDE.2...
...installation. If this device in electronic products, effective July 2006. This drive is no Federal Communications Commission verification or certification of Hazardous Substances (RoHS) Seagate designs its products to Identify and Resolve Radio-Television Interference Problems. ... interference will not occur in a residential installation. Refer to publication number 004-000-00345-4. 2.15 Environmental protection Seagate designs its products to meet environmental protection requirements worldwide, including regulations restricting certain chemical substances. Momentus 7200 FDE.2...
Momentus 7200 FDE.2 SATA Product Manual
Page 24
... humidity greater than the threshold defined by the China RoHS MCV Standard. The silver, copper, nickel and gold films used in Seagate products are especially sensitive to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845.... "X RoHS MCV 2.16 Corrosive environment Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to the presence of the printed circuit board assembly (PCBA) or ...
... humidity greater than the threshold defined by the China RoHS MCV Standard. The silver, copper, nickel and gold films used in Seagate products are especially sensitive to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845.... "X RoHS MCV 2.16 Corrosive environment Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to the presence of the printed circuit board assembly (PCBA) or ...