Page 14
... excellent performance with minimal power dissipation. 3.1 Standard features The Savvio SCSI family has the following standard features: • Integrated Ultra320 SCSI controller • Multimode SCSI drivers and receivers-single-ended (SE) and low voltage differential (LVD) • 16 bit I/O data bus • Asynchronous and synchronous data transfer protocol • Firmware downloadable...
... excellent performance with minimal power dissipation. 3.1 Standard features The Savvio SCSI family has the following standard features: • Integrated Ultra320 SCSI controller • Multimode SCSI drivers and receivers-single-ended (SE) and low voltage differential (LVD) • 16 bit I/O data bus • Asynchronous and synchronous data transfer protocol • Firmware downloadable...
Savvio 10K.1 SCSI Product Manual
Page 25
...bus operations. Case 1 - Current I/O processes not allowed during the lifetime (see SFF-8451 Specification for the SCSI device being changed Seagate Savvio SCSI disc drives support all I /O process allowed during the hot connect/disconnect operation. The SCSI bus termination and termination power ...there are presented during insertion or removal, except on the SCSI bus. Refer to the device being hot plugged uses single-ended (SE) drivers and the bus is permitted during insertion or removal Case 4 - If the device being inserted or removed. A S.M.A.R.T. Depot repair or...
...bus operations. Case 1 - Current I/O processes not allowed during the lifetime (see SFF-8451 Specification for the SCSI device being changed Seagate Savvio SCSI disc drives support all I /O process allowed during the hot connect/disconnect operation. The SCSI bus termination and termination power ...there are presented during insertion or removal, except on the SCSI bus. Refer to the device being hot plugged uses single-ended (SE) drivers and the bus is permitted during insertion or removal Case 4 - If the device being inserted or removed. A S.M.A.R.T. Depot repair or...
Savvio 10K.1 SCSI Product Manual
Page 26
During drive insertion, care should not mix devices with high voltage differential (HVD) drivers and receivers and devices with SE, LVD, or multimode drivers and receivers on -line data as the drive performs normal read/write operations. Note. Controlling S.M.A.R.T. When enabled, S.M.A.R.T. The purpose is to allow data back-up ...
During drive insertion, care should not mix devices with high voltage differential (HVD) drivers and receivers and devices with SE, LVD, or multimode drivers and receivers on -line data as the drive performs normal read/write operations. Note. Controlling S.M.A.R.T. When enabled, S.M.A.R.T. The purpose is to allow data back-up ...
Savvio 10K.1 SCSI Product Manual
Page 59
... a daisy-chain interface in which the drives will be connected in an acceptable manner (per applicable SCSI Standards) to operate correctly. D 53 These drives implement driver and receiver circuits that can successfully operate at the interface with the proper impedance in the preceeding paragraph. The drives typically operate on the daisy...
... a daisy-chain interface in which the drives will be connected in an acceptable manner (per applicable SCSI Standards) to operate correctly. D 53 These drives implement driver and receiver circuits that can successfully operate at the interface with the proper impedance in the preceeding paragraph. The drives typically operate on the daisy...
Savvio 10K.1 SCSI Product Manual
Page 64
Drives must be provided for by LVD interface drivers shall have the following output characteristics when measured at power on or after a delay of 12 sec- LC model drives do not operate at the .... [11] 8 bit devices which are connected to implement equivalent contact assignments. [3] Connector contacts are multimode devices. That is either single-ended or low voltage differential drivers/receivers (selectable using 0.025-inch (0.635 mm) centerline flat ribbon cable.
Drives must be provided for by LVD interface drivers shall have the following output characteristics when measured at power on or after a delay of 12 sec- LC model drives do not operate at the .... [11] 8 bit devices which are connected to implement equivalent contact assignments. [3] Connector contacts are multimode devices. That is either single-ended or low voltage differential drivers/receivers (selectable using 0.025-inch (0.635 mm) centerline flat ribbon cable.
Savvio 10K.1 SCSI Product Manual
Page 65
...Vin = < -0.030 V (signal assertion/logic 1) Differential voltage = +0.030 V minimum with cables are not recommended. 9.7.1.2 Single-ended drivers/receivers Single-ended I/O pin assignments are designed to the drive when termination is intended for use on drives that plug directly into a backpanel..., Rev. 3, Section 6. Single Ended Circuitry VCCA LVD Signal Drivers LVD Receiver VCCB Single Ended Receiver Single Ended Negation Driver Single Ended Ground Driver LVD Signal Drivers Single Ended Assertion Driver Ground Single Ended: GND LVD: +Signal -Signal -Signal Figure...
...Vin = < -0.030 V (signal assertion/logic 1) Differential voltage = +0.030 V minimum with cables are not recommended. 9.7.1.2 Single-ended drivers/receivers Single-ended I/O pin assignments are designed to the drive when termination is intended for use on drives that plug directly into a backpanel..., Rev. 3, Section 6. Single Ended Circuitry VCCA LVD Signal Drivers LVD Receiver VCCB Single Ended Receiver Single Ended Negation Driver Single Ended Ground Driver LVD Signal Drivers Single Ended Assertion Driver Ground Single Ended: GND LVD: +Signal -Signal -Signal Figure...
Savvio 10K.1 SCSI Product Manual
Page 74
...3 shipping 24 shipping container 31 shock 32 and vibration 32 shock mount 40 signal ground 40 single unit shipping pack 10 single-ended (SE) drivers and receivers 8 single-ended interface circuit 29, 30 site installation 19 Savvio SCSI Product Manual, Rev. See S.M.A.R.T. SE-LVD alternative 59 sense key... interface data 12 SCSI Interface Product Manual 3, 5, 7 SCSI systems error 38 SCSI systems error consideration 37 SCSI systems error management 38 Seagate support service 39 sector 13 sector interleave 12 sector sizes 12 seek error 17, 18 seek positioning error 18 segment 13 self-contained 13...
...3 shipping 24 shipping container 31 shock 32 and vibration 32 shock mount 40 signal ground 40 single unit shipping pack 10 single-ended (SE) drivers and receivers 8 single-ended interface circuit 29, 30 site installation 19 Savvio SCSI Product Manual, Rev. See S.M.A.R.T. SE-LVD alternative 59 sense key... interface data 12 SCSI Interface Product Manual 3, 5, 7 SCSI systems error 38 SCSI systems error consideration 37 SCSI systems error management 38 Seagate support service 39 sector 13 sector interleave 12 sector sizes 12 seek error 17, 18 seek positioning error 18 segment 13 self-contained 13...
Savvio 10K.1 FC Product Manual
Page 13
...; Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set on the...
...; Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set on the...
Savvio 10K.1 FC Product Manual
Page 78
... (7) 52 Download microcode with offsets mode (6) 52 drive 35 drive characteristics 11 drive ID 41 drive mounting 37, 42 drive orientation 41 drive select 61 drivers and receivers 7 dual port support 49 E electrical description of connector 61 signal characteristics 67 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 enable bypass...
... (7) 52 Download microcode with offsets mode (6) 52 drive 35 drive characteristics 11 drive ID 41 drive mounting 37, 42 drive orientation 41 drive select 61 drivers and receivers 7 dual port support 49 E electrical description of connector 61 signal characteristics 67 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 enable bypass...
Savvio 10K.4 FC Product Manual
Page 5
A iii 9.5.10 Motor start controls 62 9.5.11 SEL_6 through SEL_0 ID lines 63 9.5.12 Device control codes 65 9.6 Signal characteristics 65 9.6.1 TTL input characteristics 65 9.6.2 LED driver signals 66 9.6.3 FC Differential output 66 9.6.4 FC Differential input 66 10.0 Seagate Technology support services 68 Savvio 10K.4 FC Product Manual, Rev.
A iii 9.5.10 Motor start controls 62 9.5.11 SEL_6 through SEL_0 ID lines 63 9.5.12 Device control codes 65 9.6 Signal characteristics 65 9.6.1 TTL input characteristics 65 9.6.2 LED driver signals 66 9.6.3 FC Differential output 66 9.6.4 FC Differential input 66 10.0 Seagate Technology support services 68 Savvio 10K.4 FC Product Manual, Rev.
Savvio 10K.4 FC Product Manual
Page 12
...; Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set on the...
...; Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set on the...
Savvio 10K.4 FC Product Manual
Page 72
You must AC couple the receiver to isolate potentially different DC characteristics of the LED drive signals. 9.6.2 LED driver signals Fault and Active LED signals are located in Table 28. Table 27: LED drive signal State LED off, high LED on, low Current drive ...
You must AC couple the receiver to isolate potentially different DC characteristics of the LED drive signals. 9.6.2 LED driver signals Fault and Active LED signals are located in Table 28. Table 27: LED drive signal State LED off, high LED on, low Current drive ...
Savvio 10K.4 FC Product Manual
Page 78
... drive capacity programmable 8 drive characteristics 9 drive ID 39 drive ID/option select headers 39 drive mounting 34, 40 drive orientation 39 drive select 59 driver signals 66 drivers and receivers 6 dual port support 48 E electrical description of connector 59 signal characteristics 65 specifications 20 electromagnetic compatibility 2 electromagnetic susceptibility 33 EMI requirements 2 enable...
... drive capacity programmable 8 drive characteristics 9 drive ID 39 drive ID/option select headers 39 drive mounting 34, 40 drive orientation 39 drive select 59 driver signals 66 drivers and receivers 6 dual port support 48 E electrical description of connector 59 signal characteristics 65 specifications 20 electromagnetic compatibility 2 electromagnetic susceptibility 33 EMI requirements 2 enable...
Savvio 10K.4 FC Product Manual
Page 79
... 9 internal defects/errors 35 internal drive characteristics 9 IRAW 38 J J1 connector 39 Jumper settings page command 49 jumpers 39 L latency average rotational 9 LBdata 51 LED driver signals 66 Link Service Reject (LS_RJT) 42 link services supported 42 Lock-unlock-cache command 51 Log select command 51 Log sense command 51 logic...
... 9 internal defects/errors 35 internal drive characteristics 9 IRAW 38 J J1 connector 39 Jumper settings page command 49 jumpers 39 L latency average rotational 9 LBdata 51 LED driver signals 66 Link Service Reject (LS_RJT) 42 link services supported 42 Lock-unlock-cache command 51 Log select command 51 Log sense command 51 logic...
Savvio 10K.4 FC Product Manual
Page 82
shipping container 29 shock 30 and vibration 30 shock mount 41 signal characteristics 65 LED driver 66 single-unit shipping pack kit 8 SMART 7, 15 SMP = 1 in Mode Select command 57 SO 44, 47 spindle brake 6 Stacked connection req. 44, 47 standards 2 ...
shipping container 29 shock 30 and vibration 30 shock mount 41 signal characteristics 65 LED driver 66 single-unit shipping pack kit 8 SMART 7, 15 SMP = 1 in Mode Select command 57 SO 44, 47 spindle brake 6 Stacked connection req. 44, 47 standards 2 ...
Savvio 10K.4 SAS Product Manual
Page 52
.... Type 1 does not allow the use of 10 and 16 byte commands with PI information provide the same, common LBA count (i.e. Type 2 - Seagate products do not support Type 3. 8.8.2 Setting and determining the current Type Level A drive is initialized to a type of PI by approximately 1.56% ...attempts to rewrite the data to the transferred LBA length, i.e. 512 + 8 = 520. PI formatted drives are transmitted at the HBA and HBA driver level. Provides support of 32 byte commands. Eight bytes of Protection Information to be stored on the media, but requires a low level format which...
.... Type 1 does not allow the use of 10 and 16 byte commands with PI information provide the same, common LBA count (i.e. Type 2 - Seagate products do not support Type 3. 8.8.2 Setting and determining the current Type Level A drive is initialized to a type of PI by approximately 1.56% ...attempts to rewrite the data to the transferred LBA length, i.e. 512 + 8 = 520. PI formatted drives are transmitted at the HBA and HBA driver level. Provides support of 32 byte commands. Eight bytes of Protection Information to be stored on the media, but requires a low level format which...