ST373453FC Model Product Manual PDF
Page 4
... to change, without written permission of Seagate Technology LLC. All rights reserved. March 2003 Publication number: 100148129, Rev. Cheetah, SeaFAX, SeaFONE, SeaBOARD, and SeaTDD are registered trademarks or trademarks of Seagate Technology LLC. © 2002, 2003 Seagate Technology LLC. D Seagate, Seagate Technology, and the Seagate logo are registered trademarks or trademarks of Seagate Technology LLC. No part of their...
... to change, without written permission of Seagate Technology LLC. All rights reserved. March 2003 Publication number: 100148129, Rev. Cheetah, SeaFAX, SeaFONE, SeaBOARD, and SeaTDD are registered trademarks or trademarks of Seagate Technology LLC. © 2002, 2003 Seagate Technology LLC. D Seagate, Seagate Technology, and the Seagate logo are registered trademarks or trademarks of Seagate Technology LLC. No part of their...
ST373453FC Model Product Manual PDF
Page 11
D 1 1.0 Scope This manual describes Seagate Technology® LLC, Cheetah® 15K.3 FC (Fibre Channel) disc drives. Cheetah 15K.3 FC family disc drive Figure 1. Cheetah 15K.3 FC drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this and other Seagate Fibre Channel drives. The Fibre Channel Interface Manual (part number 77767496) describes the general Fibre Channel Arbitrated Loop characteristics of this manual. Cheetah 15K.3 FC Product Manual, Rev.
D 1 1.0 Scope This manual describes Seagate Technology® LLC, Cheetah® 15K.3 FC (Fibre Channel) disc drives. Cheetah 15K.3 FC family disc drive Figure 1. Cheetah 15K.3 FC drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this and other Seagate Fibre Channel drives. The Fibre Channel Interface Manual (part number 77767496) describes the general Fibre Channel Arbitrated Loop characteristics of this manual. Cheetah 15K.3 FC Product Manual, Rev.
ST373453FC Model Product Manual PDF
Page 13
...0805 and EN60950. 2.1.1 Electromagnetic compatibility The drive, as delivered, is the user's responsibility to the system does not adversely affect the performance of this manual and the Seagate Fibre Channel Interface Manual, part number 77767496. It is capable of meeting the...characteristics for typical applications. Cheetah 15K.3 FC Product Manual, Rev. D 3 2.0 Applicable standards and reference documentation The drive has been developed as a system peripheral to confirm compliance with the directives/standards for the European Union If this Seagate model complies with the...
...0805 and EN60950. 2.1.1 Electromagnetic compatibility The drive, as delivered, is the user's responsibility to the system does not adversely affect the performance of this manual and the Seagate Fibre Channel Interface Manual, part number 77767496. It is capable of meeting the...characteristics for typical applications. Cheetah 15K.3 FC Product Manual, Rev. D 3 2.0 Applicable standards and reference documentation The drive has been developed as a system peripheral to confirm compliance with the directives/standards for the European Union If this Seagate model complies with the...
ST373453FC Model Product Manual PDF
Page 14
...of the Taiwanese Bureau of Standards, Metrology, and Inspection (BSMI). 2.2 Reference documents Cheetah 15K.3 FC Installation Guide Seagate part number: 100148127 Fibre Channel Interface Manual Seagate part number: 77767496 ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-...-199X (SCSI-3) Enclosure Services Specification for Acoustic Test Requirement and Procedures Seagate part number: 30553-001 Package Test Specification Package Test Specification Seagate P/N 30190-001 (under 100 lb.) Seagate P/N 30191-001 (over 100 lb.) In case of conflict between ...
...of the Taiwanese Bureau of Standards, Metrology, and Inspection (BSMI). 2.2 Reference documents Cheetah 15K.3 FC Installation Guide Seagate part number: 100148127 Fibre Channel Interface Manual Seagate part number: 77767496 ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-...-199X (SCSI-3) Enclosure Services Specification for Acoustic Test Requirement and Procedures Seagate part number: 30553-001 Package Test Specification Package Test Specification Seagate P/N 30190-001 (under 100 lb.) Seagate P/N 30191-001 (over 100 lb.) In case of conflict between ...
ST373453FC Model Product Manual PDF
Page 15
... shipping and handling. Never disassemble the HDA and do not attempt to eliminate mechanical transducer adjustments and related reliability concerns. Cheetah 15K.3 FC drives decode track 0 location data from the servo data embedded on each surface to service items in the sealed enclosure (heads... Manual (part number 77767496) which can transfer data at up to 200 Mbytes per second and 400 Mbytes per second in the ANSI specifications, this drive. Cheetah 15K.3 FC Product Manual, Rev. The drive does not contain user-replaceable parts. Cheetah 15K.3 FC drives also support 2-Gbit...
... shipping and handling. Never disassemble the HDA and do not attempt to eliminate mechanical transducer adjustments and related reliability concerns. Cheetah 15K.3 FC drives decode track 0 location data from the servo data embedded on each surface to service items in the sealed enclosure (heads... Manual (part number 77767496) which can transfer data at up to 200 Mbytes per second and 400 Mbytes per second in the ANSI specifications, this drive. Cheetah 15K.3 FC Product Manual, Rev. The drive does not contain user-replaceable parts. Cheetah 15K.3 FC drives also support 2-Gbit...
ST373453FC Model Product Manual PDF
Page 17
...-unit shipping pack. For 2 gigabit operation sector sizes must be ordered. 3.9 User-installed accessories The following items which are available. Cheetah 15K.3 FC drives use a zone sparing scheme. See the Mode Select (6) parameter list table in the Number of alternate sectors (LBAs) per block. A value of zero in the Fibre Channel Interface Manual, part...
...-unit shipping pack. For 2 gigabit operation sector sizes must be ordered. 3.9 User-installed accessories The following items which are available. Cheetah 15K.3 FC drives use a zone sparing scheme. See the Mode Select (6) parameter list table in the Number of alternate sectors (LBAs) per block. A value of zero in the Fibre Channel Interface Manual, part...
ST373453FC Model Product Manual PDF
Page 19
...9 4.0 Performance characteristics This section provides detailed information concerning performance-related characteristics and features of Cheetah 15K.3 FC drives. 4.1 Internal drive characteristics Drive capacity Read/write data heads Bytes per track Bytes per surface Tracks per surface (total)...time measured from receipt of temperature, voltage, and horizontal orientation as measured on page 55 and the Fibre Channel Interface Manual (part number 77767496) for ≥ 512-byte sectors (minutes) Maximum (with zone) rpm msec 4.2 Seek performance characteristics See Section 9.5, "FC...
...9 4.0 Performance characteristics This section provides detailed information concerning performance-related characteristics and features of Cheetah 15K.3 FC drives. 4.1 Internal drive characteristics Drive capacity Read/write data heads Bytes per track Bytes per surface Tracks per surface (total)...time measured from receipt of temperature, voltage, and horizontal orientation as measured on page 55 and the Fibre Channel Interface Manual (part number 77767496) for ≥ 512-byte sectors (minutes) Maximum (with zone) rpm msec 4.2 Seek performance characteristics See Section 9.5, "FC...
ST373453FC Model Product Manual PDF
Page 20
...Mbytes/sec* per sector. To select this drive family are independent features from the host. 4.3 Start/stop the spindle. Prefetch and cache operations are given in Table 16. 4.5 Cache operation Note. 10 4.2.3 General performance characteristics Cheetah 15K.3 FC Product Manual, Rev. All default cache...on a track Yes Flaw reallocation performance impact (for more detail concerning the cache bits. If n (number of the first logical block transfer to the drive buffer storage space when it is enabled, the internal controller accepts the commands listed in page 08h. ...
...Mbytes/sec* per sector. To select this drive family are independent features from the host. 4.3 Start/stop the spindle. Prefetch and cache operations are given in Table 16. 4.5 Cache operation Note. 10 4.2.3 General performance characteristics Cheetah 15K.3 FC Product Manual, Rev. All default cache...on a track Yes Flaw reallocation performance impact (for more detail concerning the cache bits. If n (number of the first logical block transfer to the drive buffer storage space when it is enabled, the internal controller accepts the commands listed in page 08h. ...
ST373453FC Model Product Manual PDF
Page 21
...parameters, page 02h. 2. Each cache segment is actually a self-contained circular buffer whose length is 3 segments. Default is an integer number of the Mode Select parameters page 08h. The same buffer space and segmentation is first checked to change an unchangeable parameter. 4.5.1 Caching ... the moment). Divide the 7,500 Kbytes in the cache: 1. The value 0XFFFF is initiated. Drive transfers to the initiator the first logical block requested plus all data transfers to 16. Cheetah 15K.3 FC Product Manual, Rev. D 11 Of the 8,192 kbytes physical buffer space in the ...
...parameters, page 02h. 2. Each cache segment is actually a self-contained circular buffer whose length is 3 segments. Default is an integer number of the Mode Select parameters page 08h. The same buffer space and segmentation is first checked to change an unchangeable parameter. 4.5.1 Caching ... the moment). Divide the 7,500 Kbytes in the cache: 1. The value 0XFFFF is initiated. Drive transfers to the initiator the first logical block requested plus all data transfers to 16. Cheetah 15K.3 FC Product Manual, Rev. D 11 Of the 8,192 kbytes physical buffer space in the ...
ST373453FC Model Product Manual PDF
Page 22
...prefetch operation, the drive crosses a cylinder boundary...number 77767496. ARLA disables prefetch when it decides that a prefetch hit will be used to force the drive... = 0), the drive can limit the amount...can dynamically change the number of data. DRA ... require different drive caching operations ... way the drive switches the cache...however, the drive does not overwrite...contiguous blocks of segmentation. The drive does not use Mode Select page...=1), then the drive may be generated. ... are not for the drive. 4.5.2 Prefetch operation If...PM bit = 1), the number of segments is not using ...
...prefetch operation, the drive crosses a cylinder boundary...number 77767496. ARLA disables prefetch when it decides that a prefetch hit will be used to force the drive... = 0), the drive can limit the amount...can dynamically change the number of data. DRA ... require different drive caching operations ... way the drive switches the cache...however, the drive does not overwrite...contiguous blocks of segmentation. The drive does not use Mode Select page...=1), then the drive may be generated. ... are not for the drive. 4.5.2 Prefetch operation If...PM bit = 1), the number of segments is not using ...
ST373453FC Model Product Manual PDF
Page 23
An unrecoverable error, or condition, is defined as one that cannot be detected as a function of the number of word sync, or CRC error. If an unrecoverable write error occurs because of the receiver on page 63 1,200,000 hours None ...system failures are not predictable as a running disparity error, illegal code, loss of bits passed. After detecting an initial seek error, the drive automatically performs an error recovery process. Cheetah 15K.3 FC Product Manual, Rev. Less than 1 error in 1014 bits transferred with a read verify after each attempt (excluding media defects). ...
An unrecoverable error, or condition, is defined as one that cannot be detected as a function of the number of word sync, or CRC error. If an unrecoverable write error occurs because of the receiver on page 63 1,200,000 hours None ...system failures are not predictable as a running disparity error, illegal code, loss of bits passed. After detecting an initial seek error, the drive automatically performs an error recovery process. Cheetah 15K.3 FC Product Manual, Rev. Less than 1 error in 1014 bits transferred with a read verify after each attempt (excluding media defects). ...
ST373453FC Model Product Manual PDF
Page 24
...Seagate service and repair facility. A S.M.A.R.T. Troubleshooting and repair of the drive precludes the necessity for Request Sense information. 5.2 Reliability and service You can use to a different input signal. MTBF is not practical because users cannot purchase individual parts for the drive. 5.2.6 Hot plugging the drive Inserting and removing the drive...required for all drives in the period Number of operation. D coverable seek error. The MTBF target is not recommended because of Cheetah 15K.3 FC disc drives by drive malfunction. 14 Cheetah 15K.3 FC Product...
...Seagate service and repair facility. A S.M.A.R.T. Troubleshooting and repair of the drive precludes the necessity for Request Sense information. 5.2 Reliability and service You can use to a different input signal. MTBF is not practical because users cannot purchase individual parts for the drive. 5.2.6 Hot plugging the drive Inserting and removing the drive...required for all drives in the period Number of operation. D coverable seek error. The MTBF target is not recommended because of Cheetah 15K.3 FC disc drives by drive malfunction. 14 Cheetah 15K.3 FC Product...
ST373453FC Model Product Manual PDF
Page 26
All errors for each attribute. 5.2.8 Thermal monitor Cheetah 15K.3 FC drives implement a temperature warning system which exceeds the threatening temperature value. If the number of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) ... Interval Counter. 16 Cheetah 15K.3 FC Product Manual, Rev. Determining rate S.M.A.R.T. measures error rates. signals predictive failures when the drive is unacceptable. The temperature is set threshold. S.M.A.R.T. The firmware keeps a running count of the number of errors per operation...
All errors for each attribute. 5.2.8 Thermal monitor Cheetah 15K.3 FC drives implement a temperature warning system which exceeds the threatening temperature value. If the number of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) ... Interval Counter. 16 Cheetah 15K.3 FC Product Manual, Rev. Determining rate S.M.A.R.T. measures error rates. signals predictive failures when the drive is unacceptable. The temperature is set threshold. S.M.A.R.T. The firmware keeps a running count of the number of errors per operation...
ST373453FC Model Product Manual PDF
Page 27
...to any value in the range of the drive prior to Seagate for this drive is the responsibility of retries are not modified to test the drive more stringently, and the number of the host application to indicate the rounding of the drive at a system level. The short test ...All retries and recovery processes are multiple reasons why a drive may be returned to 65°C. It is 65°C, however, you specify a temperature greater than 65°C in process of the information necessary to recover the data. Cheetah 15K.3 FC Product Manual, Rev. The following conditions: ...
...to any value in the range of the drive prior to Seagate for this drive is the responsibility of retries are not modified to test the drive more stringently, and the number of the host application to indicate the rounding of the drive at a system level. The short test ...All retries and recovery processes are multiple reasons why a drive may be returned to 65°C. It is 65°C, however, you specify a temperature greater than 65°C in process of the information necessary to recover the data. Cheetah 15K.3 FC Product Manual, Rev. The following conditions: ...
ST373453FC Model Product Manual PDF
Page 29
...5.2.10 Product warranty Beginning on your original box. Seagate will be determined by calling Seagate Customer Service at customer's expense to the customer, if returned by customer at 1-800-468-3472. The drive serial number is required to the customer. You can be repaired... nonconformance to the applicable specifications will pay for Seagate products on the date of components improperly packaged or obviously damaged in a non-approved container voids the drive warranty. Cheetah 15K.3 FC Product Manual, Rev. Seagate repair centers may refuse receipt of shipment to ...
...5.2.10 Product warranty Beginning on your original box. Seagate will be determined by calling Seagate Customer Service at customer's expense to the customer, if returned by customer at 1-800-468-3472. The drive serial number is required to the customer. You can be repaired... nonconformance to the applicable specifications will pay for Seagate products on the date of components improperly packaged or obviously damaged in a non-approved container voids the drive warranty. Cheetah 15K.3 FC Product Manual, Rev. Seagate repair centers may refuse receipt of shipment to ...
ST373453FC Model Product Manual PDF
Page 31
..., the peak starting current must return to accept selection by 3.2%. Where multiple units are measured after the drive signifies that its power-up . 5. Cheetah 15K.3 FC Product Manual, Rev. Current and power specified at 299) I/Os per second. Decreasing +12 ...at 295, ST336753 at 306 and ST318453 at nominal voltages. Instantaneous +12V current peaks will exceed these values. Parameters, other than 1.7% of the drive. 6.1 None. N (number of drives tested) = 6, 35 Degrees C ambient. [2] For +12 V, a -10% tolerance is not less than spindle start (max) DC 3...
..., the peak starting current must return to accept selection by 3.2%. Where multiple units are measured after the drive signifies that its power-up . 5. Cheetah 15K.3 FC Product Manual, Rev. Current and power specified at 299) I/Os per second. Decreasing +12 ...at 295, ST336753 at 306 and ST318453 at nominal voltages. Instantaneous +12V current peaks will exceed these values. Parameters, other than 1.7% of the drive. 6.1 None. N (number of drives tested) = 6, 35 Degrees C ambient. [2] For +12 V, a -10% tolerance is not less than spindle start (max) DC 3...
ST373453FC Model Product Manual PDF
Page 46
...air 36 Cheetah 15K.3 FC Product Manual, Rev. Connect the plus side to keep temperatures at or below the temperatures specified in Section 6.4.1 in Section 6.4.1. The rack, cabinet, or drawer environment for the drive must be mounted in any orientation. D Drive Front Pin... (across pins 2 and 4). LED indicator connector 8.2.1 J6 connector requirements Recommended mating connector part number: Berg receptacle, 6-position, Berg part number 690-006. 8.3 Drive orientation The drive may be oriented, or air flow directed, so that adequate heat removal is connected to this...
...air 36 Cheetah 15K.3 FC Product Manual, Rev. Connect the plus side to keep temperatures at or below the temperatures specified in Section 6.4.1 in Section 6.4.1. The rack, cabinet, or drawer environment for the drive must be mounted in any orientation. D Drive Front Pin... (across pins 2 and 4). LED indicator connector 8.2.1 J6 connector requirements Recommended mating connector part number: Berg receptacle, 6-position, Berg part number 690-006. 8.3 Drive orientation The drive may be oriented, or air flow directed, so that adequate heat removal is connected to this...
ST373453FC Model Product Manual PDF
Page 49
D 39 9.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah 15K.3 FC drives. Cheetah 15K.3 FC Product Manual, Rev. Table 5: Fibre Channel SCSI FCP task management functions Task name Terminate task ... in the Fibre Channel Interface Manual (part number 77767496). 9.1 FC-AL features This section lists the Fibre Channel-specific features supported by Cheetah 15K.3 FC drives. 9.1.1 Fibre Channel link service frames Table 4 lists the link services supported by Cheetah 15K.3 FC drives. Table 4: Link services supported Type of ...
D 39 9.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah 15K.3 FC drives. Cheetah 15K.3 FC Product Manual, Rev. Table 5: Fibre Channel SCSI FCP task management functions Task name Terminate task ... in the Fibre Channel Interface Manual (part number 77767496). 9.1 FC-AL features This section lists the Fibre Channel-specific features supported by Cheetah 15K.3 FC drives. 9.1.1 Fibre Channel link service frames Table 4 lists the link services supported by Cheetah 15K.3 FC drives. Table 4: Link services supported Type of ...
ST373453FC Model Product Manual PDF
Page 55
D 45 9.3 SCSI commands supported Table 14 lists the SCSI commands supported by Cheetah 15K.3 FC drives. Table 14: Supported commands Command code 00h 01h 03h 04h 07h 08h 0Ah 0Bh 12h 15h 16h 17h 18h 1Ah 1Bh 1Ch ... bytes Y Format unit [1] Y Reassign blocks Y Read Y Write Y Seek Y Inquiry Y Vital product data page (00h) Y Unit serial number page (80h) Y Implemented operating def. page (81h) Y Device Identification page (83h) Y Firmware numbers page (C0h) Y Date code page (C1h) Y Jumper settings page (C2h) Y Device Behavior page (C3h) Y Mode select (same pages...
D 45 9.3 SCSI commands supported Table 14 lists the SCSI commands supported by Cheetah 15K.3 FC drives. Table 14: Supported commands Command code 00h 01h 03h 04h 07h 08h 0Ah 0Bh 12h 15h 16h 17h 18h 1Ah 1Bh 1Ch ... bytes Y Format unit [1] Y Reassign blocks Y Read Y Write Y Seek Y Inquiry Y Vital product data page (00h) Y Unit serial number page (80h) Y Implemented operating def. page (81h) Y Device Identification page (83h) Y Firmware numbers page (C0h) Y Date code page (C1h) Y Jumper settings page (C2h) Y Device Behavior page (C3h) Y Mode select (same pages...
ST373453FC Model Product Manual PDF
Page 59
... request and receive from the default values list and stored into the flash E-PROM. Parameters in the Fibre Channel Interface Manual. Table 15: Cheetah 15K.3 FC inquiry data Bytes 0-15 16-31 32-47 48-63 64-79 80-95 96-111 112-127 128-143 Data (hex) ...where the values are not changeable by this method. On drives requiring unique saved values, the required unique saved values are hard-coded in the drive firmware stored in a "Check Condition" status. S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 18 through 26 of new firmware into...
... request and receive from the default values list and stored into the flash E-PROM. Parameters in the Fibre Channel Interface Manual. Table 15: Cheetah 15K.3 FC inquiry data Bytes 0-15 16-31 32-47 48-63 64-79 80-95 96-111 112-127 128-143 Data (hex) ...where the values are not changeable by this method. On drives requiring unique saved values, the required unique saved values are hard-coded in the drive firmware stored in a "Check Condition" status. S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 18 through 26 of new firmware into...