(English)
Page 1
DV210AE* DV210AG* DV220AE* DV220AG* Gas and Electric Dryer user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DV220AE-02810A-03_EN.indd 1 2010-06-28 ¿ÀÈÄ 5:53:27
DV210AE* DV210AG* DV220AE* DV220AG* Gas and Electric Dryer user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DV220AE-02810A-03_EN.indd 1 2010-06-28 ¿ÀÈÄ 5:53:27
(English)
Page 3
... or property damage. Unplug the power plug from the wall socket. Do NOT attempt. Do NOT touch. Always contact your new Samsung Dryer. WARNING - Flexible venting materials are known to minimize the risk of severe injury or death, follow all possible conditions and ... the machine is installed, it must be of Fire • Clothes dryer installation must be easily crushed, and trap lint. This manual contains valuable information on your manufacturer about problems or conditions you do not cover all installation instructions. Risk of a specific type identified by...
... or property damage. Unplug the power plug from the wall socket. Do NOT attempt. Do NOT touch. Always contact your new Samsung Dryer. WARNING - Flexible venting materials are known to minimize the risk of severe injury or death, follow all possible conditions and ... the machine is installed, it must be of Fire • Clothes dryer installation must be easily crushed, and trap lint. This manual contains valuable information on your manufacturer about problems or conditions you do not cover all installation instructions. Risk of a specific type identified by...
(English)
Page 12
...(1 cm) gas line on your dryer DV220AE-02810A-03_EN.indd 12 2010-06-28 ¿ÀÈÄ 5:53:29 A "T" handle manual gas valve must be installed immediately upstream of the system. THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH... of 3' (36"). - If a flexible gas connector is no constant burning pilot. The National Fuel Gas Code requires that an accessible, approved manual gas shut-off valve be resistant to install your dryer. Flexible gas lines must be installed within 6' of any pressure testing of your dryer's ...
...(1 cm) gas line on your dryer DV220AE-02810A-03_EN.indd 12 2010-06-28 ¿ÀÈÄ 5:53:29 A "T" handle manual gas valve must be installed immediately upstream of the system. THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH... of 3' (36"). - If a flexible gas connector is no constant burning pilot. The National Fuel Gas Code requires that an accessible, approved manual gas shut-off valve be resistant to install your dryer. Flexible gas lines must be installed within 6' of any pressure testing of your dryer's ...
(English)
Page 20
... selection. The cycle minimizes wrinkling by the cycle name will illuminate when Wrinkle Prevent is displayed. The Air Fluff cycle tumbles the load in the Manual Dry cycles (Time Dry, Wrinkle Release, or Air Fluff cycles). Time can be removed at the end of intermittent tumbling in the load and shuts...
... selection. The cycle minimizes wrinkling by the cycle name will illuminate when Wrinkle Prevent is displayed. The Air Fluff cycle tumbles the load in the Manual Dry cycles (Time Dry, Wrinkle Release, or Air Fluff cycles). Time can be removed at the end of intermittent tumbling in the load and shuts...
(English)
Page 21
... those labeled Tumble Dry. For permanent press, synthetics, lightweight cottons, or items labeled Tumble Dry Medium. Provides the lowest heated dry temperature possible. When using Manual Dry cycles, time can only be adjusted by fluctuating humidity levels. Start/Pause 8 selection button Press to pause and restart programs. 9 Power button 10 Mixed...
... those labeled Tumble Dry. For permanent press, synthetics, lightweight cottons, or items labeled Tumble Dry Medium. Provides the lowest heated dry temperature possible. When using Manual Dry cycles, time can only be adjusted by fluctuating humidity levels. Start/Pause 8 selection button Press to pause and restart programs. 9 Power button 10 Mixed...
(English)
Page 31
06 appendix CYCLE CHART Cycle Normal Sensor Dry Heavy Duty Perm Press Manual Dry Delicates Time Dry Wrinkle Release Air Fluff Temp control High (Medium) High (No change) Medium (No change) Low (No change) High Medium (No change) Default Sensor dry level Normal dry Normal dry Normal dry Normal dry - - Time 42 min 58 min 32 min 27 min 40 min 25 min 20 min Drying Time 39 min 55 min 29 min 24 min 35 min 20 min Cooling Time 3 min 3 min 3 min 3 min 5 min 5 min 20 min Wrinkle prevent Time 90 min DV220AE-02810A-03_EN.indd 31 appendix _31 2010-06-28 ¿ÀÈÄ 5:53:38
06 appendix CYCLE CHART Cycle Normal Sensor Dry Heavy Duty Perm Press Manual Dry Delicates Time Dry Wrinkle Release Air Fluff Temp control High (Medium) High (No change) Medium (No change) Low (No change) High Medium (No change) Default Sensor dry level Normal dry Normal dry Normal dry Normal dry - - Time 42 min 58 min 32 min 27 min 40 min 25 min 20 min Drying Time 39 min 55 min 29 min 24 min 35 min 20 min Cooling Time 3 min 3 min 3 min 3 min 5 min 5 min 20 min Wrinkle prevent Time 90 min DV220AE-02810A-03_EN.indd 31 appendix _31 2010-06-28 ¿ÀÈÄ 5:53:38