Rane MT4 Support and Manuals
Popular Rane MT4 Manual Pages
MA 4 Amplifier Data Sheet - Page 1
... times. VR 2 Volume Remotes can control the level from constant load power to advanced dynamics control, qualify the MA 4 for sensitivity setting, load Z
and temperature
Accessories
MT 4
MADE IN U.S.A.
Data Sheet-1
RANE CORP.
4
IN OUT + - 100V 70V COM
+ - 100V 70V COM IN OUT
3
IN OUT + - 100V 70V COM
+ - 100V 70V COM IN OUT...
MA 4 Amplifier Data Sheet - Page 2
Oversampled instantaneous attack Limit set for good load estimate
Conditions/Comments Each leg, differential, 1 kHz
256...signal ..........All channels driven AC Mains PFC DC/DC Unit: Conformity ..........Construction ..........Size ..........Weight: Shipping: Size ..........Weight:
Data Sheet-2
Specification 10 kΩ +22 dBu +22 to +4 dBu Attenuate only; 0 dB to 20 kHz
+0, -3 dB
>90 dB
A-...
MA 4 Amplifier Data Sheet - Page 3
RANE CORP. Decay is 1.5 seconds;
Attack is 3 dB per octave, Butterworth alignment. 8 Each channel is 10 dB. 6 Downward EXPander reduces noise in standby
(Slave channel with Euroblock strain-relief connectors allow continuous adjustment from +22 dBu to +4 dBu. Master channels write Fault Flag status. Fault = 0 volts. • Channels set for Internal, automatic ...
MA 4 Amplifier Data Sheet - Page 6
...slave operation determined by temperature.
An IEC connector and IEC cord shall be a Rane Corporation Model MA 4.
A rear panel dipswitch shall provide a selection of any amplifier channel. ...40°C ambient temperature. OutpOutudtBprue t10P0oWwer
Input dBu Compressor Response
Architectural Specifications
The unit shall be provided. Euroblock connectors shall provide a means ...
MA 4 Amplifier Data Sheet - Page 7
...you . Floating the FAULT FLAG or connecting it to ground turns the channel on , set its rear panel switch to the FAULT FLAG holds the amplifier in low power standby with...13
+-
1 SENSITIVITY
13
+-
+-
22 4 dBu
+-
22 4 dBu
+-
22 4 dBu
+-
22 4 dBu
+-
+-
+-
+- RANE CORP. MA 4
COMMERCIAL AUDIO EQUIPMENT 24TJ
R
100-240V 50/60 Hz 500 WATTS
INT EXT 4
OUTPUTS
Class 2 Wiring
INT EXT
INT ...
MA 4 Amplifier Data Sheet - Page 8
...WEB rane.com
Data Sheet-8
All features & specifications subject to these inputs. For information about Fault Flag operation (applications and reported faults) see the Manual, page 3.
The Rane VR... have an amplifier channel report a fault to a control system or back up amplifier, set it to Master. RANE CORP. ZONE 3
+- ZONE 1
+- MA 4
MULTICHANNEL AMPLIFIER
Advanced Application - INT ...
MT 4 Transformer Data Sheet / Manual - Page 1
...(model TF 4) are available separately, allowing the installer to -use with four transformers (shown below) • KT 4 rackmount tray only • TF 4 individual transformers
Data Sheet-1 Since voltage capability doubles with just the number of the 70 V system, this ideal for the 100 volt tap is moved up accordingly. DATA SHEET
MT 4
MULTICHANNEL TRANSFORMER
MT 4
MULTICHANNEL
TRANSFORMER...
MT 4 Transformer Data Sheet / Manual - Page 2
...100 watts with surface operating
tempertaures > 60°C. 2.
Maximum Power Loss: MT 4
MULTICHANNEL TRANSFORMER Rear Panel
MT 4
MADE IN U.S.A. Electrical 1. Magnetizing Inductance: Primary: > 1H (1V...-White < 500 mΩ 2. Leakage Inductance: Primary (secondaries shorted): 20 µH. Performance Specifications 1. RANE CORP.
4
IN OUT + - 100V 70V COM
3
IN OUT + - 100V 70V ...
VR2 Remote Data Sheet / Manual - Page 1
...to the 3-pin connector by Rane's warranty; Voltages Turn the ... a secured installation, you know. Connect the VR2's control voltage Vc (wiper) connection(s) first. Such damage is the better part of nicks...excess heat is easier than a second trip to the VR2, requiring replacement of static. "Vr" on the VR2 ("REF" terminal on ... / MANUAL
VR2
VOLUME REMOTE
Description
The VR2 mounts in the 5 volt supply if...
VR2 Remote Data Sheet / Manual - Page 2
...signal cable CAT. # 9896 Shielded remote control signal cable CAT. #9877, CAT. #9852
WEICO WIRE & CABLE INC. Please contact your installation and local electrical codes.
Wire Types Variations in -One Block Diagram and Schematic
VERSATILE INPUT PORT
0-5V
+5v /
100 mA
1 2 3 4 5 6...355-6000 FAX 425-347-7757 WEB rane.com
All features & specifications subject to change without notice.
MA 4 Amplifier Manual - Page 2
... of the polarized or grounding-type plug. No user serviceable parts inside. The plug on or pinched particularly at least 3 mm in each pole shall be installed in a residential installation. NOTE: This equipment has been tested and found to comply with a dry cloth. 7.
Keep these instructions. 2. WARNING
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN...
MA 4 Amplifier Manual - Page 4
... FAULT FLAG operation (applications and reported faults), see Safety Instructions. 10. Manual-1 The universal switching power supply works with any load), dynamics control, Fault status
and Load status are indicated for each channel. Connect speaker loads (rear panel). 9. RANE CORP. Set COMPressor to go!
WEAR PARTS: This product contains no filter) • Amplifier heat load...
MA 4 Amplifier Manual - Page 5
... clipping, ensuring signal integrity and uninterrupted service. º The peak signal detector for...PROTECTION DO NOT REMOVE THIS SCREW. Attack is 3:1; RANE CORP.
FAULT FLAG
Active Low 321
321
MODE
HIGH-...the used to determine the Limiter threshold setting. º The front panel Load indicator....+
-
+
-
+-+-+-+-
4321
Manual-2
MODE
HIGH-PASS
20Hz
40Hz
60Hz
80Hz
MASTER
COMP
SLAVE
ON
ON...
MA 4 Amplifier Manual - Page 6
...the
EXTernal amplifier input. Drive Master and Slave audio inputs from the same sou3r4c5e4,82and set to the limit threshold and the difference in low-power standby (Ready indicator flashing) ...
4
Fault Load Ready
3
Limit
6
Comp
12
Exp
24
dB Headroom
Fault Load Ready
ON
Manual-3 Master and Slave front panel power switches
must be ON.
100-240V
FOR CONTINUED GROUNDING PROTECTION...
MA 4 Amplifier Manual - Page 7
...dBu
CW
Fault Reporting
To have an amplifier channel report a fault to a control system or back up amplifier, set its rear panel switch to SLAVE. The
GND
Fault Flag is held high (+5 volts) during normal operation and ... WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB rane.com
Manual-4
All features & specifications subject to these inputs (diagram at right). ometer 10k to 100k Ω...
Rane MT4 Reviews
Do you have an experience with the Rane MT4 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Rane yet.
Earn 750 points for your review!