Panasonic FV-08WQ1 Support and Manuals
Get Help and Manuals for this Panasonic item
This item is in your list!
View All Support Options Below
Free Panasonic FV-08WQ1 manuals!
Problems with Panasonic FV-08WQ1?
Ask a Question
Free Panasonic FV-08WQ1 manuals!
Problems with Panasonic FV-08WQ1?
Ask a Question
Popular Panasonic FV-08WQ1 Manual Pages
FV-08WQ1 Owner's Manual (English) - Page 1
... ...3 Specifications ...4 Unpacking ...4 General safety precautions 4 Installation I (In new construction 5-6 Installation II (In remodeling 7-8 Maintenance ...9-10 Product Service ...10 Please retain for future reference. Failure to install, operate or service the Panasonic Ventilating Fan.
INSTALLATION INSTRUCTIONS
Through the Wall Fan "Whisper Wall"
Ventilating Fan
FV-08WQ1
READ...
FV-08WQ1 Owner's Manual (English) - Page 2
... is used. Reference installation drawing
Wall thickness: ...FV-08WQ1
Part name
Drawing
Wall sleeve
Screw I (4 x 30)
Quantity
Part name
Screw III (4 x 8) 1
Template (Pattern paper) 4
Mounting plate
Exterior hood 1
Screw II (4 x 6) (for new construction only)
2
Externsion sleeve
Drawing
Quantity 1
1
1
1
Description
This Panasonic wall mounted ventilating fan uses a propeller fan...
FV-08WQ1 Owner's Manual (English) - Page 4
..., electric shock, or injury to the service panel.
Use this area. C. Specifications
Model Air direction V Hz Power consumption*1 (W)
FV-08WQ1 Exhaust 120 60
17
Speed*1 (r/min.)
1340
*1 At 0.0" Static pressure, (Pa)
*2 For main unit only. A) 3. Follow the heating equipment manufacturer's guideline and safety standards such as the National Electrical Code (NEC) and the Occupation Safety...
FV-08WQ1 Owner's Manual (English) - Page 5
... the market)
Power supply AC 120 V 60 Hz
Green
Earth ground
6. When this ventilating fan can be installed on page 7, Installation II.
1. Remove one of 12.7 - 16 mm (1/2 - 5/8"). white to black...hole
B
Hole in the junction box. Using the wire nuts, connect the house power wires to ventilating fan wires. (Fig. 4): black to white; CAUTION: Reattach the junction box cover carefully so that ...
FV-08WQ1 Owner's Manual (English) - Page 6
...nails. Attach the electrical connectors to each other, hook the frame latches onto the mounting plate latch, and secure the fan unit to the frame. Reattach the grille to the mounting plate with the supplied screw (screw III). (Fig 9)
...Seam
Interior wall material
Finish with the frame.
12. Insert the attached exterior hood from the fan unit.
Installation I (In new construction) -
FV-08WQ1 Owner's Manual (English) - Page 8
... from the fan unit. (Fig. 8 on Junction box the market)
Power supply AC 120 V 60 Hz
Green
Earth ground
10. Reattach the grille to paint the exterior hood.
Installation II (In... the house power wires to black; Before painting, thoroughly wipe off any oil on page 5): black to ventilating fan wires. (Fig. 4 on the surface. Flexible conduit Frame
Latch Latch
Fig. 14
Fig. 15
Mounting ...
FV-08WQ1 Owner's Manual (English) - Page 10
...dampened with a clean cloth. (Fig. 20)
5. Blade
Fan unit (Frame)
CAUTION: Press on the grille until it clicks.
No service information is designed and manufactured to locate the PASC Authorized Service Center nearest you.)
PANASONIC HOME AND COMMERCIAL PRODUCTS COMPANY One Panasonic Way, Secaucus, NJ 07094 PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3...
Installation Instructions - Page 1
... ...3 Specifications ...4 Unpacking ...4 General safety precautions 4 Installation I (In new construction 5-6 Installation II (In remodeling 7-8 Maintenance ...9-10 Product Service ...10 Please retain for future reference.
Failure to install, operate or service the Panasonic Ventilating Fan. INSTALLATION INSTRUCTIONS
Through the Wall Fan "Whisper Wall"
Ventilating Fan
FV-08WQ1
READ...
Installation Instructions - Page 2
...service life with an inner diameter of 207 mm (8 5/32") and a length of components
FV-08WQ1
Part name
Drawing
Wall sleeve
Screw I (4 x 30)
Quantity
Part name
Screw III (4 x 8) 1
Template (Pattern paper) 4
Mounting plate
Exterior hood 1
Screw II (4 x 6) (for new construction only)
2
Externsion sleeve
Drawing
Quantity 1
1
1
1
Description
This Panasonic wall mounted ventilating...
Installation Instructions - Page 4
...When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as appropriate for this application. Installation Work And Electrical Wiring Must Be Done By Qualified Persons In Accordance With All Applicable Codes And Standards, Including Fire Rated Construction. G. Specifications
Model Air direction V Hz Power consumption*1 (W)
FV-08WQ1 Exhaust 120 60...
Installation Instructions - Page 5
... the thickness of the knockout holes in the wall stud, secure the flange to the reference installation drawing when the wall thickness is more than 152.4 mm (6") on the wall sleeve (Fig. 2).
When this ventilating fan can be installed on an interior wall with supplied screws (Screw I (In new construction)
NOTE: If the wall...
Installation Instructions - Page 6
...the grille from the outside to the outside of the hood.
6
Fig. 6
Fig. 7
Grille
Fan unit (Frame)
Fig. 8
Latch Latch
Mounting plate
Frame
Grille
Fig. 9 Before painting, thoroughly wipe... wall sleeve with four screws or nails.
Reattach the grille to paint the exterior hood. Installation I (In new construction) - Press the spring locks on the sides and pull the grille ...
Installation Instructions - Page 7
... the junction box cover by removing two screws (C). (Fig. 11)
4.
Remove the screws (D) and replace the wall sleeve flange with the end of the wall sleeve which is protruding from the wall sleeve by...mm (8 1/2") hole in the interior wall
Fig. 10
2. Hole in the exterior wall. Fasterners, etc. Installation II (In remodeling)
NOTE: If the wall thickness is more than 152.4 mm (6") on page 2.
...
Installation Instructions - Page 8
... to black; mastic tape
Seam
Exterior hood
Finish with the supplied screw (screw III). (Fig 16) 14. Installation II (In remodeling)- Insulation around ducts can reduce energy loss and inhibit mold growth.
8. CAUTION: Press on the... knockout hole in place as possible to help prevent condensation from the fan unit. (Fig. 8 on page 5): black to ventilating fan wires. (Fig. 4 on page 6) 13.
Installation Instructions - Page 10
... PASC Authorized Service Center nearest you.)
Panasonic Corporation of covers. Your product is provided for customers. Wipe them dry with a non-abrasive kitchen detergent, remove any dirt from the fan blades and body.
This unit should your unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTER is maintained to support your...
Panasonic FV-08WQ1 Reviews
Do you have an experience with the Panasonic FV-08WQ1 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.
Earn 750 points for your review!