Panasonic CU-E12RKUA Support and Manuals

Get Help and Manuals for this Panasonic item

View All Support Options Below
Free Panasonic CU-E12RKUA manuals!
Problems with Panasonic CU-E12RKUA?

Ask a Question

Popular Panasonic CU-E12RKUA Manual Pages

E12RKUA Installation Manual - Page 1

... Model A B C D E9RKUA, E12RKUA...repairing a refrigeration parts. INSTALLATION...set and the service port of the installation plate). Ensure the hooks are fully inserted to section 4. 4 EVACUATION OF THE EQUIPMENT WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in instructions. When installing at the join. Please fasten the installation...
E12RKUA Operating Manual - Page 3

...manual...guide 1 3 Inserting the batteries 2 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover 2 3 Clock setting TIMER ON SET 1 Press CLOCK 1 2 3 2 Set the time OFF CANCEL 1 AC RC SET...6-7 To learn more 8 Cleaning instructions 9 Troubleshooting 10-11 Information 12 Accessories • Remote control •...
E12RKUA Service Manual - Page 1

Any attempt to service or repair the products dealt with the service manual for use this manual together with in this service information by anyone else could result in attempting to service a product. CU-2E18NBU and CU-5E36QBU, Order No. Products powered by electricity should be assured of no refrigerant leakage during the installation or repairing of potential dangers in serious ...
E12RKUA Service Manual - Page 2

... connection please refer to Multi outdoor manual).........71 17.3 Remote Control Button 72 18. TABLE OF CONTENTS 1. Specification 5 3. Block Diagram 18 7.1 CS-E9RKUAW CU-E9RKUA CS-E12RKUAW CU-E12RKUA 18 7.2 CS-E18RKUAW CU-E18RKUA CS-E24RKUAW CU-E24RKUA 19 8. Printed Circuit Board 28 10.1 Indoor Unit 28 10.2 Outdoor Unit 30 11. Installation Instruction (E18RK and E24RK 41 12...
E12RKUA Service Manual - Page 7

Model Indoor Outdoor CS-E9RKUAW CU-E9RKUA CS-E12RKUAW CU-E12RKUA DRY BULB WET BULB DRY BULB WET BULB Indoor Operation Range (Cooling) (°F / ...42.8°F Wet Bulb) 3. Cooling capacities are subjected to change without prior notice for further improvement. 7 Specifications are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature...
E12RKUA Service Manual - Page 52

...4 5 Close position Figure 2 13.5.2 Horizontal Airflow (CU-E9RKUA CU-E12RKUA) The horizontal airflow direction louvers can be set using remote control, the vane will shift to close ... 13.5.1.1 CU-E9RKUA CU-E12RKUA Operation Mode Airflow Direction Heating Cooling Soft Dry A Auto with Heat Exchanger Temperature B C Manual Auto Manual Auto Manual 13.5.1.2 CU-E18RKUA CU-E24RKUA Vane...
E12RKUA Service Manual - Page 75

... To Clear Memorized Error Code after breakdown repair, the Timer LED will be used until repaired. Note: Display only for 4 seconds) will not blink. The code "H00" (no codes are matched, Power... no codes are matched, Power LED will light up for E C O N A V I OFF/ON AUTO COMFORT MODE TEMP POW ERFU QUIET L/ F A N SPEED AIR SWING TIMER ON 1 2 OFF SET CHECK CLOCK SET 3 ...
E12RKUA Service Manual - Page 89

...; The supply power is detected for the specified indoor or outdoor unit PCB. ● Replace the indoor and outdoor unit PCB. 89 Is the indoor and outdoor unit model number matched? NO ● Match the compatible model (follow specification). NO Change for its requirement by the indoor/outdoor transmission. Check indoor and outdoor PCB...
E12RKUA Service Manual - Page 120

20.2 Heat Mode Performance Data Unit setting: Standard piping length, Hi Fan, Heat mode at 86°F Voltage: 230V 20.2.1 CS-E9RKUAW CU-E9RKUA Rated frequency (compressor speed is ... 1104 23.9 (75.02) TC IP 13471 1114 14239 1089 13891 1071 20.2.2 CS-E12RKUAW CU-E12RKUA Rated frequency (compressor speed is fixed during forced heating or cooling for capacity measurement and diagnosis purpose...
E12RKUA Service Manual - Page 130

21.3 Piping Length Correction Factor The characteristic of the unit has to be corrected in accordance with the piping length. 21.3.1 CS-E9RKUAW CU-E9RKUA CS-E12RKUAW CU-E12RKUA Cooling Capacity Correction Factor 1.040 1.030 1.020 1.010 1.000 0.990 0.980 0.970 0.960 9.5 1.060 1.050 1.040 1.030 1.020 1.010 1.000 0.990 0.980 0.970 0.960 0.950...
E12RKUA Service Manual - Page 138

22.2 Outdoor Unit 22.2.1 CU-E9RKUA CU-E12RKUA 38 49 34 48 47 29 31 28 11 2 45 46 6 7 4 5 20 50 51 30 40 3 19 23 36 37 24 39 43 12 18 22 17 8 42 13 10 44 9 1 27 26 32 15 16 14 33 41 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 138
E12RKUA Service Manual - Page 139

...CWE161010 G0C193J00002 CWB001058 CWD041161A CWA43C2432 CWA341065 CWG87C900 CWB111061 CWA43C2393 CWB121047 CWG861078 CWG50C2388 CWG712210 CWG712209 CWG565107 CU-E12RKUA CWB32C4129 ← ← ← CWB021654 CWB011367 CWA73C9161R ← CWE04C1558 CWA50C3315 ...40 41 42 43 44 45 46 47 48 49 PART NAME & DESCRIPTION CHASSIS COMPLETE FAN MOTOR BRACKET SCREW - VALVE) HEATER BAG-COMPLETE STRAINER V-...
E12RKUA Service Manual - Page 140

SAFETY REF. NO. 50 51 PART NAME & DESCRIPTION SOUND PROOF MATERIAL SOUND PROOF MATERIAL QTY. 1 1 CU-E9RKUA CWG302292 CWG302569 (Note)  All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).  "O" marked parts are recommended to be kept in stock. CU-E12RKUA ← ← REMARK 140
E12RKUA Submittal Sheet - Page 1

... Rifled Row x stage x FPI Size 2 x 15 x 21 1 x 12-13/32 x 24 Tube Size (in.) Drain Connection Size (in . Split System Submittal Data System: E12RKUA Indoor: CS-E12RKUAW Outdoor: CU-E12RKUA Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15 15...
CU-E12RKUAW Outdoor Unit Parts List - Page 1

22.2 Outdoor Unit 22.2.1 CU-E9RKUA CU-E12RKUA 38 49 34 48 47 29 31 28 11 2 45 46 6 7 4 5 20 50 51 30 40 3 19 23 36 37 24 39 43 12 18 22 17 8 42 13 10 44 9 1 27 26 32 15 16 14 33 41 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 138

Panasonic CU-E12RKUA Reviews

Do you have an experience with the Panasonic CU-E12RKUA that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Panasonic yet.

Popular Panasonic CU-E12RKUA Search Terms

The following terms are frequently used to search for Panasonic CU-E12RKUA support:

Ask a New Question
Use the box below to post a new question about Panasonic CU-E12RKUA.
Manuals / Documents
Download any of our Panasonic CU-E12RKUA manuals for free!

We have the following 5 documents available for the Panasonic CU-E12RKUA:
  • E12RKUA Service Manual
  • E12RKUA Operating Manual
  • CU-E12RKUAW Outdoor Unit Parts List
  • E12RKUA Submittal Sheet
  • E12RKUA Installation Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Panasonic Manuals

Find free Panasonic CU-E12RKUA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Panasonic Reviews

View thousands of Panasonic CU-E12RKUA user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Panasonic customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Panasonic customer service rankings, employee comments and much more from our sister site.

Panasonic Recalls

Find comprehensive Panasonic recall information updated hourly on RecallOwl.com.