Instruction Manual
Page 63
... following methods: • Set the built-in wide flash adapter to the upper or left direction. • Set the SB-27's flash operation to Standard TTL Flash (not Matrix Balanced Fill-Flash.) • Mount a Nikkor lens without built-in either TTL or manual mode, first decide which the secondary (Slave) unit(s). Series/N90, F70-Series/N70 cameras...
... following methods: • Set the built-in wide flash adapter to the upper or left direction. • Set the SB-27's flash operation to Standard TTL Flash (not Matrix Balanced Fill-Flash.) • Mount a Nikkor lens without built-in either TTL or manual mode, first decide which the secondary (Slave) unit(s). Series/N90, F70-Series/N70 cameras...
Instruction Manual
Page 64
...- (Cameras in Groups I thru TTL multiple flash operation procedures See page 66 on usable flash units and accessories for cameras in Groups I thru VI) When using the SB-27 as a slave unit, set the power switch to activate the Forced TTL function (see page 69). Forced TTL ...flash unit to the slave flash unit(s). -Turn OFF all flash units when connecting. 3 Set the flash mode selector of all the flash units to TTL. -Do not set the camera setting switch to ˚ in normal TTL Auto Flash mode. NOTE Using the SB-27 as a slave flash unit (for multiple flash operation. 1 Mount the SB-27 ...
...- (Cameras in Groups I thru TTL multiple flash operation procedures See page 66 on usable flash units and accessories for cameras in Groups I thru VI) When using the SB-27 as a slave unit, set the power switch to activate the Forced TTL function (see page 69). Forced TTL ...flash unit to the slave flash unit(s). -Turn OFF all flash units when connecting. 3 Set the flash mode selector of all the flash units to TTL. -Do not set the camera setting switch to ˚ in normal TTL Auto Flash mode. NOTE Using the SB-27 as a slave flash unit (for multiple flash operation. 1 Mount the SB-27 ...
Instruction Manual
Page 65
... (1), SB-50DX (1), SB-30 (1), SB-29s/29 (1), SB-28/28DX (1), SB-27 (1), SB-26 (1), SB-25 (1), SB-24 (1), SB-23 (4), SB-22s (1), SB-22 (6), SB-21 (4), SB-20 (9), SB-17 (4), SB-16 (4), SB-15 (4), SB-14 (1), SB-11 (1), SB-140 (1) Coefficient numbers in parentheses above are usable: SB-29s/29, SB-28/28DX, SB-27, SB-26, SB-25, SB-24, SB-23, SB-22s, SB-22, SB-20, SB-18, SB-16B, SB-15 • For more Speedlights mounted on the camera's hot shoe as slave flash...
... (1), SB-50DX (1), SB-30 (1), SB-29s/29 (1), SB-28/28DX (1), SB-27 (1), SB-26 (1), SB-25 (1), SB-24 (1), SB-23 (4), SB-22s (1), SB-22 (6), SB-21 (4), SB-20 (9), SB-17 (4), SB-16 (4), SB-15 (4), SB-14 (1), SB-11 (1), SB-140 (1) Coefficient numbers in parentheses above are usable: SB-29s/29, SB-28/28DX, SB-27, SB-26, SB-25, SB-24, SB-23, SB-22s, SB-22, SB-20, SB-18, SB-16B, SB-15 • For more Speedlights mounted on the camera's hot shoe as slave flash...
Instruction Manual
Page 66
Group I thru VI System chart for TTL multiple flash • SB-11, SB-14, SB-140, and SB-21B Speedlights cannot be used with DA-20/DP-20) F65-Series/N65-Series F-801s/N8008s F-801/N8008 Pronea ...GMBTIVOJU SC-23 SB-14 SB-11 SB-140 SB-21B SB-15 SB-20 SB-22 SB-22s SB-23 SB-27 SB-30 SB-50DX SB-16B SB-24 SB-25 SB-26 SB-28/28DX SB-29/29s SB-80DX SB-16A SB-17 SB-21A SC-14 Items marked A on page 66 are connected to item A on page 67. Multiple flash operation-(Cameras in Groups...Series (with DW-20/DW-21) F4-Series (with the F-401/N4004 or F-401s/N4004s either as a master or a slave unit.
Group I thru VI System chart for TTL multiple flash • SB-11, SB-14, SB-140, and SB-21B Speedlights cannot be used with DA-20/DP-20) F65-Series/N65-Series F-801s/N8008s F-801/N8008 Pronea ...GMBTIVOJU SC-23 SB-14 SB-11 SB-140 SB-21B SB-15 SB-20 SB-22 SB-22s SB-23 SB-27 SB-30 SB-50DX SB-16B SB-24 SB-25 SB-26 SB-28/28DX SB-29/29s SB-80DX SB-16A SB-17 SB-21A SC-14 Items marked A on page 66 are connected to item A on page 67. Multiple flash operation-(Cameras in Groups...Series (with DW-20/DW-21) F4-Series (with the F-401/N4004 or F-401s/N4004s either as a master or a slave unit.
Instruction Manual
Page 68
... on each light output in the same way. 4 Follow the same procedures as a slave flash unit SB-80DX, SB-30, SB-29s/29, SB-28/28DX, SB-27, SB-26, SB-25, SB-24, SB-22s, SB-22, SB-20, SB-17, SB-16, SB-15, SB-14, SB-11, SB-140 Usable remote cords (optional) (See page 77.) Sync Cord SC-11/SC-15 TTL Remote Cord SC-17...
... on each light output in the same way. 4 Follow the same procedures as a slave flash unit SB-80DX, SB-30, SB-29s/29, SB-28/28DX, SB-27, SB-26, SB-25, SB-24, SB-22s, SB-22, SB-20, SB-17, SB-16, SB-15, SB-14, SB-11, SB-140 Usable remote cords (optional) (See page 77.) Sync Cord SC-11/SC-15 TTL Remote Cord SC-17...
Instruction Manual
Page 69
...9 15 4 72 41 2 0.6 -The t indictor in the LCD panel blinks to "NOTE: Using the SB-27 as a slave unit(s) in multiple flash operation. (See page 63.) Please refer to indicate that the SB-27 is in Groups I thru VI. Setting Forced TTL and Forced A modes (Applicable to all camera groups) •...; Select Forced TTL mode when using the SB-27 as a slave flash unit" on page 64. • Select Forced A (non-TTL Auto Flash) mode when you intentionally want easy exposure compensation with cameras in Forced TTL mode. Setting and canceling...
...9 15 4 72 41 2 0.6 -The t indictor in the LCD panel blinks to "NOTE: Using the SB-27 as a slave unit(s) in multiple flash operation. (See page 63.) Please refer to indicate that the SB-27 is in Groups I thru VI. Setting Forced TTL and Forced A modes (Applicable to all camera groups) •...; Select Forced TTL mode when using the SB-27 as a slave flash unit" on page 64. • Select Forced A (non-TTL Auto Flash) mode when you intentionally want easy exposure compensation with cameras in Forced TTL mode. Setting and canceling...
Instruction Manual
Page 77
...in sync with the master unit to connect the SB-27 with cameras with the SB-27. Sync Terminal Adapter AS-15 Use Sync Terminal Adapter AS-15 to provide TTL, non-TTL, or Manual operation. Wireless Slave Flash Controller SU-4 Useful for multiple flash photography, the SU-4 features a built-in ...SB-27 on the F4-Series camera. Use the SC-24 when the DW-20 or DW-21 is mounted on a camera without an accessory shoe, or performing Multiple Flash operation in , movable light sensor and an accessory shoe for TTL multiple flash operation. The SU-4's light sensor not only triggers the slave...
...in sync with the master unit to connect the SB-27 with cameras with the SB-27. Sync Terminal Adapter AS-15 Use Sync Terminal Adapter AS-15 to provide TTL, non-TTL, or Manual operation. Wireless Slave Flash Controller SU-4 Useful for multiple flash photography, the SU-4 features a built-in ...SB-27 on the F4-Series camera. Use the SC-24 when the DW-20 or DW-21 is mounted on a camera without an accessory shoe, or performing Multiple Flash operation in , movable light sensor and an accessory shoe for TTL multiple flash operation. The SU-4's light sensor not only triggers the slave...