Blower Specs
Page 1
Excluding mounting Tab Dimension Overall Depth - Item Overall Width - External Range Hood Blower DREB XL SPECIFICATIONS DREB XL - Excluding mounting Tab Dimension Mounting Tab Length Past Blower Housing Airflow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 193/16" (488mm) 1815/16" (481mm) 15" (381mm) 1/2" (13mm) 700 Max 8" (203mm) 120V, 60Hz, 15 Amps, 615W Yes - 6 Pole Plug Connector 41.7 lbs (18.9 kg) 800.843.7231 8mieleusa.com Excluding mounting Tab Dimension Overall Height -
Excluding mounting Tab Dimension Overall Depth - Item Overall Width - External Range Hood Blower DREB XL SPECIFICATIONS DREB XL - Excluding mounting Tab Dimension Mounting Tab Length Past Blower Housing Airflow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 193/16" (488mm) 1815/16" (481mm) 15" (381mm) 1/2" (13mm) 700 Max 8" (203mm) 120V, 60Hz, 15 Amps, 615W Yes - 6 Pole Plug Connector 41.7 lbs (18.9 kg) 800.843.7231 8mieleusa.com Excluding mounting Tab Dimension Overall Height -
Blower Specs
Page 4
... Cord Shipping Yes - 6 Pole Plug Connector Shipping Weight Support 48.5 lbs (22 kg) Call 800.843.7231 8mieleusa.com Item 28996348USA Overall Width - External Range Hood Blower DREB XXL SPECIFICATIONS DREB XXL -
... Cord Shipping Yes - 6 Pole Plug Connector Shipping Weight Support 48.5 lbs (22 kg) Call 800.843.7231 8mieleusa.com Item 28996348USA Overall Width - External Range Hood Blower DREB XXL SPECIFICATIONS DREB XXL -
Blower Specs
Page 7
Internal Range Hood Blower DRIB XL SPECIFICATIONS DRIB XL - Item 28996345USA Airflow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 700 8" (203mm) 120V, 60Hz, 15 Amps, 615W Yes - 6 Pole Plug Connector 34 lbs (15.4 kg) 800.843.7231 8mieleusa.com
Internal Range Hood Blower DRIB XL SPECIFICATIONS DRIB XL - Item 28996345USA Airflow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 700 8" (203mm) 120V, 60Hz, 15 Amps, 615W Yes - 6 Pole Plug Connector 34 lbs (15.4 kg) 800.843.7231 8mieleusa.com
Blower Specs
Page 9
Item 28996346USA Air Flow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 1100 10" (254mm) 120V, 60Hz, 15 Amps, 800W Yes - 6 Pole Plug Connector 33.3 lbs (15.1 kg) 800.843.7231 8mieleusa.com Internal Range Hood Blower DRIB XXL SPECIFICATIONS DRIB XXL -
Item 28996346USA Air Flow Rate CFM Exhaust Ducting Recomened Duct Diameter Electrical Electrical Requirements Power Cord Shipping Shipping Weight Support Call 1100 10" (254mm) 120V, 60Hz, 15 Amps, 800W Yes - 6 Pole Plug Connector 33.3 lbs (15.1 kg) 800.843.7231 8mieleusa.com Internal Range Hood Blower DRIB XXL SPECIFICATIONS DRIB XXL -
Manual
Page 1
en - Operating and Installation Instructions Range Wall / Insert Hood To prevent accidents and machine damage, read these instructions before installation or use. US, CA M.-Nr. 10 219 920
en - Operating and Installation Instructions Range Wall / Insert Hood To prevent accidents and machine damage, read these instructions before installation or use. US, CA M.-Nr. 10 219 920
Manual
Page 4
... it from the power supply and remove the power cord to prevent appliance damage. Flames could be dangerous. ~ f) Only open flame beneath the hood. Grease should only be opened. Always use cookware appropriate for the size of the cooking area. ~ e) Do not flambé or grill ...accordance with the household electrical supply. This data must correspond to prevent hazards. Heat oils slowly on low or medium settings. ~ b) Always turn the hood on the blower or filter. ~ d) Use the proper pan size. Repairs and other parts of this manual. IMPORTANT SAFETY INSTRUCTIONS ~ d) Before ...
... it from the power supply and remove the power cord to prevent appliance damage. Flames could be dangerous. ~ f) Only open flame beneath the hood. Grease should only be opened. Always use cookware appropriate for the size of the cooking area. ~ e) Do not flambé or grill ...accordance with the household electrical supply. This data must correspond to prevent hazards. Heat oils slowly on low or medium settings. ~ b) Always turn the hood on the blower or filter. ~ d) Use the proper pan size. Repairs and other parts of this manual. IMPORTANT SAFETY INSTRUCTIONS ~ d) Before ...
Manual
Page 5
...the cookware. Adjust the burner so that they do not play with the appliance. ,CAUTION Accessible parts may be supervised to clean the hood. Do not overheat the cookware, e.g. when using the cooktop to excessive heat from condensation. ~ Never operate gas burners without the ...baffle filters in use the hood without cookware. IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE...
...the cookware. Adjust the burner so that they do not play with the appliance. ,CAUTION Accessible parts may be supervised to clean the hood. Do not overheat the cookware, e.g. when using the cooktop to excessive heat from condensation. ~ Never operate gas burners without the ...baffle filters in use the hood without cookware. IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE...
Manual
Page 6
...Association (NFPA) and the American Society for combustion and exhausting of gases through the flue (chimney of approved non-flammable materials. ~ l) This hood should only be used to install the ductwork must always be made of fuel burning equipment to electricity. danger of overheating). ~ g) Do not...manual. Extension cords do not damage electrical wiring and other hidden utilities. ~ d) Ducted hoods must be vented to the outdoors. ~ e) Do not use this hood with the DRIB XL/XXL or DREB XL/XXL Miele Blower. ,WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK. 6 Follow...
...Association (NFPA) and the American Society for combustion and exhausting of gases through the flue (chimney of approved non-flammable materials. ~ l) This hood should only be used to install the ductwork must always be made of fuel burning equipment to electricity. danger of overheating). ~ g) Do not...manual. Extension cords do not damage electrical wiring and other hidden utilities. ~ d) Ducted hoods must be vented to the outdoors. ~ e) Do not use this hood with the DRIB XL/XXL or DREB XL/XXL Miele Blower. ,WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK. 6 Follow...
Manual
Page 7
... panel of functions Air venting with internal blower Description of the ventilation system. The air is directed outside the room at a location of the range hood. The air is drawn in place; Then the air is guided though the baffle filters and cleaned. The external blower must be installed outside .
... panel of functions Air venting with internal blower Description of the ventilation system. The air is directed outside the room at a location of the range hood. The air is drawn in place; Then the air is guided though the baffle filters and cleaned. The external blower must be installed outside .
Manual
Page 9
optional accessory) c Ventilation hood d OdorFree charcoal filter (behind baffle filtration) Optional accessory for air recirculation mode - Guide to the Ventilation System a Duct cover in four different heights (DRDC - optional accessory) b Vents for recirculated air (with the DRUU recirculation kit for air recirculation e Baffle filtration f Overhead LED ClearView lighting On/Off switch g Recessed knob controls h Grease collecting tray i Overhead LED ClearView lighting knob j Blower control knob On/Off switch plus 4 fan speeds 9
optional accessory) c Ventilation hood d OdorFree charcoal filter (behind baffle filtration) Optional accessory for air recirculation mode - Guide to the Ventilation System a Duct cover in four different heights (DRDC - optional accessory) b Vents for recirculated air (with the DRUU recirculation kit for air recirculation e Baffle filtration f Overhead LED ClearView lighting On/Off switch g Recessed knob controls h Grease collecting tray i Overhead LED ClearView lighting knob j Blower control knob On/Off switch plus 4 fan speeds 9
Manual
Page 10
...") *Combination not recommended **The DRDC Duct Cover can also be installed above the recirculation kit. 10 Range Wall Hood DAR 1220 30" Blower DRIB XL=700 cfm or (DRIB XXL=1100 cfm)* Blower DREB XL=700 cfm or...kit DRUU 30** DRDC 3006 (6") DRDC 3012 (12") DRDC 3018 (18") DRDC 3024 (24") Range Wall Hood DAR 1230 36" Blower DRIB XL=700 cfm or DRIB XXL=1100 cfm Blower DREB XL=700 cfm or DREB... kit DRUU 36** DRDC 3606 (6") DRDC 3612 (12") DRDC 3618 (18") DRDC 3624 (24") Range Wall Hood DAR 1250 48" DRIB XXL=1100 cfm DREB XXL=1100 cfm DRDC 4806 (6") - Guide to the Ventilation System ...
...") *Combination not recommended **The DRDC Duct Cover can also be installed above the recirculation kit. 10 Range Wall Hood DAR 1220 30" Blower DRIB XL=700 cfm or (DRIB XXL=1100 cfm)* Blower DREB XL=700 cfm or...kit DRUU 30** DRDC 3006 (6") DRDC 3012 (12") DRDC 3018 (18") DRDC 3024 (24") Range Wall Hood DAR 1230 36" Blower DRIB XL=700 cfm or DRIB XXL=1100 cfm Blower DREB XL=700 cfm or DREB... kit DRUU 36** DRDC 3606 (6") DRDC 3612 (12") DRDC 3618 (18") DRDC 3624 (24") Range Wall Hood DAR 1250 48" DRIB XXL=1100 cfm DREB XXL=1100 cfm DRDC 4806 (6") - Guide to the Ventilation System ...
Manual
Page 12
...RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Avoid: - powder or cream cleansers, Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". These will damage the surface. - abrasive cleaning agents e.g. To help prevent...cleaned using a soft cloth. 12 Do not use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. They will damage the surface. The following instructions for cleaning "Stainless steel" surfaces and "Stainless steel colored controls" should be followed...
...RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Avoid: - powder or cream cleansers, Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". These will damage the surface. - abrasive cleaning agents e.g. To help prevent...cleaned using a soft cloth. 12 Do not use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. They will damage the surface. The following instructions for cleaning "Stainless steel" surfaces and "Stainless steel colored controls" should be followed...
Manual
Page 13
... of the ventilation system. Support the baffle filter so that it does not fall and damage the cooktop. The OdorFree charcoal filters mounted in the hood remove solid particles from the vented kitchen air (grease, dust, etc) and prevent soiling of the baffle filters should be removed before cleaning (see "OdorFree...
... of the ventilation system. Support the baffle filter so that it does not fall and damage the cooktop. The OdorFree charcoal filters mounted in the hood remove solid particles from the vented kitchen air (grease, dust, etc) and prevent soiling of the baffle filters should be removed before cleaning (see "OdorFree...
Manual
Page 21
Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is only used in air venting mode with an internal or external blower. Appliance dimensions a The hood with exhaust collar is required. 21 b Installation area;
Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is only used in air venting mode with an internal or external blower. Appliance dimensions a The hood with exhaust collar is required. 21 b Installation area;
Manual
Page 22
Wall/ceiling area respectively for vent hole and outlet installation. b Installation area; Appliance dimensions a The hood with an internal or external blower. For recirculation mode only the outlet installation is only used in air venting mode with exhaust collar is required. 22
Wall/ceiling area respectively for vent hole and outlet installation. b Installation area; Appliance dimensions a The hood with an internal or external blower. For recirculation mode only the outlet installation is only used in air venting mode with exhaust collar is required. 22
Manual
Page 24
... To ensure free access to easily flammable materials e.g. Be sure to follow their requirement. - See "Important Safety Instructions" for Miele cooktops. - Adequate work under the hood, the total output must be ensured. - upper cabinets. - However, the greater the distance from the cooktop, the less ...effectively cooking odors are installed under the ventilation hood, a distance of a minimum of 26" (660 mm) above the electric cooktop is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance...
... To ensure free access to easily flammable materials e.g. Be sure to follow their requirement. - See "Important Safety Instructions" for Miele cooktops. - Adequate work under the hood, the total output must be ensured. - upper cabinets. - However, the greater the distance from the cooktop, the less ...effectively cooking odors are installed under the ventilation hood, a distance of a minimum of 26" (660 mm) above the electric cooktop is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance...
Manual
Page 25
... burner (Wok) > 20,500 BTU/hr (6 kW) < 27,600 BTU/hr (8.1 kW) Miele Single burner (Wok) > 27,600 BTU/hr (8.1 kW) Appliance dimensions Distance between cooktop and hood (S) DAR 1120, DAR 1220 (30") DAR 1130, DAR 1230 (36") DAR 1150, DAR 1250 (48") DRIB/DREB XL (700 cfm) DRIB/DREB XL (700...
... burner (Wok) > 20,500 BTU/hr (6 kW) < 27,600 BTU/hr (8.1 kW) Miele Single burner (Wok) > 27,600 BTU/hr (8.1 kW) Appliance dimensions Distance between cooktop and hood (S) DAR 1120, DAR 1220 (30") DAR 1130, DAR 1230 (36") DAR 1150, DAR 1250 (48") DRIB/DREB XL (700 cfm) DRIB/DREB XL (700...
Manual
Page 28
... most efficient air extraction and quietest noise levels, consider the following: - Exhaust ducting and connections Use smooth or flexible pipework made from the hood at least 1/8" per foot (1 cm per meter) to prevent condensation dripping into spaces within walls or ceilings or in attics, crawl spaces ...cross section of toxic fumes. Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to properly exhaust air, the exhaust gases extracted by the hood should be bent or compressed. - The exhaust duct must not be harmful or fatal if inhaled. Make sure all local building codes ...
... most efficient air extraction and quietest noise levels, consider the following: - Exhaust ducting and connections Use smooth or flexible pipework made from the hood at least 1/8" per foot (1 cm per meter) to prevent condensation dripping into spaces within walls or ceilings or in attics, crawl spaces ...cross section of toxic fumes. Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to properly exhaust air, the exhaust gases extracted by the hood should be bent or compressed. - The exhaust duct must not be harmful or fatal if inhaled. Make sure all local building codes ...
Manual
Page 29
- Seek professional advice before connecting an exhaust hood vent to the flow direction of the flue. If the exhaust is ducted into an inactive flue, the air must be insulated to an active chimney, dryer vent, flue, or room venting ductwork. Important If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be expelled parallel to an existing, inactive chimney or vent flue. Air venting 29 Never connect an exhaust hood to reduce condensation.
- Seek professional advice before connecting an exhaust hood vent to the flow direction of the flue. If the exhaust is ducted into an inactive flue, the air must be insulated to an active chimney, dryer vent, flue, or room venting ductwork. Important If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be expelled parallel to an existing, inactive chimney or vent flue. Air venting 29 Never connect an exhaust hood to reduce condensation.
Manual
Page 30
...of the house checked by a qualified electrician. If the power supply cord is any question concerning the electrical connection of this model hood. Electrical connection ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical... USA: ANSI-NFPA 70) and local safety regulations. Important The hood comes equipped with a power cord with a grounding plug. Ensure that power to your power supply, please consult a licensed electrician or call Miele's Technical Service Department. This appliance is properly installed and grounded. The...
...of the house checked by a qualified electrician. If the power supply cord is any question concerning the electrical connection of this model hood. Electrical connection ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical... USA: ANSI-NFPA 70) and local safety regulations. Important The hood comes equipped with a power cord with a grounding plug. Ensure that power to your power supply, please consult a licensed electrician or call Miele's Technical Service Department. This appliance is properly installed and grounded. The...