Miele DA 2210 Support and Manuals

Get Help and Manuals for this Miele item

View All Support Options Below
Free Miele DA 2210 manuals!
Problems with Miele DA 2210?

Ask a Question

Most Recent Miele DA 2210 Questions

Joystick Operated Extractor Fan Miele 2210
Hi, My Miele 2210 Extractor fan seems to work fine with the exception that it has 1 speed instead o...
(Posted by rchapman15868 10 years ago)

Popular Miele DA 2210 Manual Pages

Operating and Installation manual - Page 1

US, CA M.-Nr. 07 773 240 Operating and Installation Instructions Ventilation System DA 2280 DA 2210 To prevent accidents and appliance damage, read these instructions before installation or use. en -
Operating and Installation manual - Page 2

Contents IMPORTANT SAFETY INSTRUCTIONS 3 Functional description 7 Guide to the Ventilation System 8 Operation 10 Joystick ... 19 Changing the light bulb 20 After Sales Service 21 Installation instructions 23 Caring for the environment 24 Appliance dimensions 25 Distance between cooktop and hood (S 27 Installation 28 Installing the joystick 31 Joystick extension 31 Electrical connection...
Operating and Installation manual - Page 3

... And Vapors. ~ This appliance is designed to vent cooking smoke and odors only. ~ This appliance is suitable for installation above gas or electric cooking surfaces. ~ This appliance... instructions in a safe place and pass them on to any doubt, have questions, contact Miele. ~ b) Before servicing or cleaning the appliance, switch power off at the service panel and lock the service disconnecting...
Operating and Installation manual - Page 4

... codes and standards. IMPORTANT SAFETY INSTRUCTIONS ...settings. ~ b) Always turn the hood on the fan or filter. ~ d) Use the proper pan size. This data must correspond to accumulate on when cooking at high settings...Installation diagram" and in the "Cleaning and care" section of the housing be dangerous. ~ f) Only open flame beneath the hood. Repairs and other parts of this manual...
Operating and Installation manual - Page 6

... ventilating ductwork. ~ j) Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. ~ k) Any fittings, sealant, or materials used to install the ductwork must be done by qualified person(s) in the "Appliance dimensions" section of this hood with all applicable codes and standards, including fire-rated construction. ~ b) Sufficient air is...
Operating and Installation manual - Page 7

... operation: Air extraction Recirculation mode The air is equipped with one non-return flap, the DA 2210 comes with a non-return flap. The active charcoal filter and the installation kit may be purchased from Miele. Functional description The ventilation hood offers two modes of the exhaust fan automatically opens the flap blowing the inside air...
Operating and Installation manual - Page 9

Guide to turn off automatically after either 5 or 15 minutes. to show how long the grease filters have been in use (see "Cleaning and care"). - The fan can be set... to the Ventilation System a Control panel b Joystick The fan and light can be operated with the joystick. This button is also used : - to be replaced... for recirculation mode DA 2280: 2 filters DA 2210: 4 filters e...
Operating and Installation manual - Page 10

... "3" are usually sufficient for hoods operated in airflow for normal cooking. Factors such as narrow duct diameters and bends will affect this value. DA 2210 The maximum air flow capacity ... indicator of the fan power scale lights. Fan performance DA 2280 The maximum air flow capacity is 850 cfm. Intensive setting Level "4" should be a slight decrease in recirculation mode...
Operating and Installation manual - Page 19

...indicator light will be ordered from Miele. ^ Remove the grease filters to access the charcoal filters. Cleaning and care Active charcoal filter DA 2280 uses 2 active charcoal filters DA 2210 uses 4 active charcoal filters In... least every 6 months or when they no longer absorb odors efficiently. ^ After replacing the charcoal filters, press and hold the charcoal filter button for 6 seconds to ...
Operating and Installation manual - Page 21

... guarantee the safety, reliability, and longevity of your home. Only genuine Miele parts installed by 5 years of worry free ownership. Our goal is visible when the grease filters are removed. Please note that guarantees repairs by Miele. MieleCare (USA only) MieleCare, our Extended Service Contract program, gives you and/or your appliance. To learn more about...
Operating and Installation manual - Page 28

... the wire, pull it out of the bracket. The top half (motor and fan assembly) should be installed within cabinetry and kitchen islands. This flap automatically closes when the hood is equipped with one, the DA 2210 with two non-return flaps. ,CAUTION To avoid risk of outside air and room air can occur...
Operating and Installation manual - Page 29

... "Air extraction" for further information on installing the exhaust hose. ^ DA 2210: The hood has two vent collars for two 6" (150 mm) diameter exhaust hoses. dai2717 ^ Place the exhaust hose onto the vent collar of the hood. 29 dai2699 ^ If using a 6" (150 mm) diameter exhaust hose, attach the supplied vent collar to the exhaust hose with a hose clamp...
Operating and Installation manual - Page 30

.... When installing the recirculation vents make sure that the slats point towards the center of the hood. 30 If site conditions are not suitable for air extraction, the appliance must be ordered from your Miele dealer or the Technical Service Dept. Installation Recirculation mode DA 2280 installation needs one installation kit and two active charcoal filters DA 2210 installation needs two...
Operating and Installation manual - Page 35

... or repair work is properly installed and grounded. Grounding Instructions This appliance must be plugged into a outlet which is any question concerning the electrical connection of the house checked by a qualified electrician in strict accordance with a NEMA 5-15 molded plug for connection to your power supply, please consult a licensed electrician or call Miele's Technical Service...
DA2210 - Page 1

... connects right rear top. Product and Cut-out Dimensions Built-in accordance with local codes. • Center unit over cooking surface • Distance "S" is not to scale. SPECIFICATION SHEETS 011208 Minimum distance "S" is: - 24" for electric surfaces - 24" for gas surfaces based on BTU output (see hood instructions for details ) 43 5/16" NOTE: Drawing is...

Miele DA 2210 Reviews

Do you have an experience with the Miele DA 2210 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Miele yet.

Popular Miele DA 2210 Search Terms

The following terms are frequently used to search for Miele DA 2210 support:

Ask a New Question
Use the box below to post a new question about Miele DA 2210.
Manuals / Documents
Download any of our Miele DA 2210 manuals for free!

We have the following 2 documents available for the Miele DA 2210:
  • Operating and Installation manual
  • DA2210

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Miele Manuals

Find free Miele DA 2210 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Miele Reviews

View thousands of Miele DA 2210 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Miele customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Miele customer service rankings, employee comments and much more from our sister site.

Miele Recalls

Find comprehensive Miele recall information updated hourly on RecallOwl.com.