...ventilation openings are acceptable.Companion appliance spacing should also be considered for ease of the door are for the recommended spacing for this dryer. ■■ Additional spacing should be considered. W10558994 01/2013 PRODUCT MODEL NUMBERS MGD3000B, MGD4000B, MGD4200B, MGD6000A, MGD7000A,... MGD8000A Front view: 27" (686 mm) 381/8" (968 mm) Gas Dryer Side view: 3/4"* (18 mm) Back view: 61/4" (159 mm) Recommended Installation Spacing: Water inlet (Steam Models Only) 53/4"* (146 mm...
...ventilation openings are acceptable.Companion appliance spacing should also be considered for ease of the door are for the recommended spacing for this dryer. ■■ Additional spacing should be considered. W10558994 01/2013 PRODUCT MODEL NUMBERS MGD3000B, MGD4000B, MGD4200B, MGD6000A, MGD7000A,... MGD8000A Front view: 27" (686 mm) 381/8" (968 mm) Gas Dryer Side view: 3/4"* (18 mm) Back view: 61/4" (159 mm) Recommended Installation Spacing: Water inlet (Steam Models Only) 53/4"* (146 mm...
Dimension Guide
Page 2
...our products, we reserve the right to the outside. 4" (102 mm) diameter vent is required. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to change without notice. Louvered Hood Acceptable Style: Box Hood Angled Hood Determine vent path: ■■ Select route that may be ...installed within 6 ft (1.8 m) of dryer. ■■ Reduce performance, resulting in Vent System Chart. gas. A time-delay fuse or circuit breaker and a separate circuit are for...
...our products, we reserve the right to the outside. 4" (102 mm) diameter vent is required. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to change without notice. Louvered Hood Acceptable Style: Box Hood Angled Hood Determine vent path: ■■ Select route that may be ...installed within 6 ft (1.8 m) of dryer. ■■ Reduce performance, resulting in Vent System Chart. gas. A time-delay fuse or circuit breaker and a separate circuit are for...
Installation Guide
Page 3
IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 3
IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 3
Installation Guide
Page 4
...and parts before purchasing parts. Check that opens to LP gas 4 NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed for gas installations: Additional parts may ... Read "Electrical Requirements" and "Venting Requirements" before starting installation. Optional Equipment: (Not supplied with dryer) Refer to your "Use and Care Guide" for information about accessories available for your dryer. 8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections) Pipe-joint ...
...and parts before purchasing parts. Check that opens to LP gas 4 NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed for gas installations: Additional parts may ... Read "Electrical Requirements" and "Venting Requirements" before starting installation. Optional Equipment: (Not supplied with dryer) Refer to your "Use and Care Guide" for information about accessories available for your dryer. 8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections) Pipe-joint ...
Installation Guide
Page 5
... weather, or at temperatures below 40° F (4° C). If using a pedestal, you will need : ■■A location allowing for an electric dryer. ■■If using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20... - 120 psi (138 - 827 kPa). measurement NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for your washer using the "Y" connector and short hose (if needed) which are provided. ■■Level floor with elbow. You may use the...
... weather, or at temperatures below 40° F (4° C). If using a pedestal, you will need : ■■A location allowing for an electric dryer. ■■If using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20... - 120 psi (138 - 827 kPa). measurement NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for your washer using the "Y" connector and short hose (if needed) which are provided. ■■Level floor with elbow. You may use the...
Installation Guide
Page 6
...further information, see "Assistance or Service" section in the top and bottom of the door are required. Additional installation requirements: This dryer is adequate and in conformance with a door, minimum ventilation openings in your dealer. A copy of above codes standard may be ... 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of installation and servicing; Recommended installation clearances (dryer only): Mobile home installations require: ■■Metal exhaust system hardware, available for ease of the line. It is recommended. A time-...
...further information, see "Assistance or Service" section in the top and bottom of the door are required. Additional installation requirements: This dryer is adequate and in conformance with a door, minimum ventilation openings in your dealer. A copy of above codes standard may be ... 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of installation and servicing; Recommended installation clearances (dryer only): Mobile home installations require: ■■Metal exhaust system hardware, available for ease of the line. It is recommended. A time-...
Installation Guide
Page 7
...not modify the plug provided with all local codes and ordinances. SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must be grounded. Do not use an adapter. A time-delay fuse or circuit breaker is required. If using a replacement power...for electric current. WARNING: Improper connection of the equipment- Do not modify the plug provided with appropriate conversion. ■■Your dryer must be plugged into a grounded 3 prong outlet. It is properly grounded. LP Gas Conversion: IMPORTANT: Conversion must be made ...
...not modify the plug provided with all local codes and ordinances. SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must be grounded. Do not use an adapter. A time-delay fuse or circuit breaker is required. If using a replacement power...for electric current. WARNING: Improper connection of the equipment- Do not modify the plug provided with appropriate conversion. ■■Your dryer must be plugged into a grounded 3 prong outlet. It is properly grounded. LP Gas Conversion: IMPORTANT: Conversion must be made ...
Installation Guide
Page 8
...NOTE: Pipe-joint compounds that complies with the B149.1, Natural Gas and Propane Installation Code. Gas supply pressure testing ■■The dryer must be easy to reach for opening and closing . The location should be disconnected from the floor, depending on the pedestal model....;■If local codes permit, use LP gas, 3/8" LP compatible copper tubing can be installed within six (6) ft. (1.8 m) of the dryer in elevation. See illustration. ■■1/2" IPS pipe is recommended. ■■3/8" approved aluminum or copper tubing is recommended that comes out ...
...NOTE: Pipe-joint compounds that complies with the B149.1, Natural Gas and Propane Installation Code. Gas supply pressure testing ■■The dryer must be easy to reach for opening and closing . The location should be disconnected from the floor, depending on the pedestal model....;■If local codes permit, use LP gas, 3/8" LP compatible copper tubing can be installed within six (6) ft. (1.8 m) of the dryer in elevation. See illustration. ■■1/2" IPS pipe is recommended. ■■3/8" approved aluminum or copper tubing is recommended that comes out ...
Installation Guide
Page 9
..., test all non-flared male fittings. Flared male fitting B. Connect gas supply to connect the exhaust vent. Place a carton corner post from dryer carton; Open shut-off valve in leveling legs B A A. Open valve Open shut-off valve A B A. Closed valve B. Non-flared ...male fitting Remove red cap from gas pipe. Leave enough room to dryer 1. Plan pipe fitting connection (option 1) D C diamond marking Examine leveling legs, find diamond marking. Correct any leak found. 9 NOTE: For LP...
..., test all non-flared male fittings. Flared male fitting B. Connect gas supply to connect the exhaust vent. Place a carton corner post from dryer carton; Open shut-off valve in leveling legs B A A. Open valve Open shut-off valve A B A. Closed valve B. Non-flared ...male fitting Remove red cap from gas pipe. Leave enough room to dryer 1. Plan pipe fitting connection (option 1) D C diamond marking Examine leveling legs, find diamond marking. Correct any leak found. 9 NOTE: For LP...
Installation Guide
Page 10
... ordinances. IMPORTANT: Observe all joints. ■■ Exhaust vent must not be connected or secured with rigid metal or flexible metal vents. Dryer exhaust must not be connected into interior of duct and catch lint. Good Better 4" (102 mm) heavy metal exhaust vent ■■...Vent System Chart". Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid crushing and kinking. VENTING Venting Requirements Exhaust hoods: ■■ An exhaust hood should...
... ordinances. IMPORTANT: Observe all joints. ■■ Exhaust vent must not be connected or secured with rigid metal or flexible metal vents. Dryer exhaust must not be connected into interior of duct and catch lint. Good Better 4" (102 mm) heavy metal exhaust vent ■■...Vent System Chart". Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid crushing and kinking. VENTING Venting Requirements Exhaust hoods: ■■ An exhaust hood should...
Installation Guide
Page 11
... drying times and increased energy usage. Rigid metal or flexible metal vent G. Exhaust outlet Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of elbows and turns. ■■When using elbows or making turns... 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have the dryer converted. Wall D. Exhaust systems longer than those specified will help achieve best drying performance. C D E A. To determine maximum exhaust length, add one 90° turn...
... drying times and increased energy usage. Rigid metal or flexible metal vent G. Exhaust outlet Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of elbows and turns. ■■When using elbows or making turns... 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have the dryer converted. Wall D. Exhaust systems longer than those specified will help achieve best drying performance. C D E A. To determine maximum exhaust length, add one 90° turn...
Installation Guide
Page 12
The dryer must fit over the exhaust hood. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. 1. Turn cold water off, remove ... to exhaust hood with new rubber washer. Run vent to male end of the 2 ft (0.6 m) inlet hose. Avoid 90° turns. Then attach "Y" connector to dryer location using the new inlet hoses (not supplied). Connect vent to exhaust hood CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to...
The dryer must fit over the exhaust hood. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. 1. Turn cold water off, remove ... to exhaust hood with new rubber washer. Run vent to male end of the 2 ft (0.6 m) inlet hose. Avoid 90° turns. Then attach "Y" connector to dryer location using the new inlet hoses (not supplied). Connect vent to exhaust hood CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to...
Installation Guide
Page 13
A ttach long hose to "Y" connector and tighten couplings Attach one of dryer back panel. NOTE: Do not overtighten. Using pliers, tighten the couplings an additional two-thirds turn . NOTE: Do not overtighten. Screw on coupling by hand ... to fill valve at bottom of the 5 ft (1.5 m) inlet hose ends to the coupling can result. Remove protective cap from water inlet valve. Damage to dryer fill valve and tighten coupling Using pliers, tighten the couplings with additional two-thirds turn. 3. Attach washer cold inlet hose to the coupling can result...
A ttach long hose to "Y" connector and tighten couplings Attach one of dryer back panel. NOTE: Do not overtighten. Using pliers, tighten the couplings an additional two-thirds turn . NOTE: Do not overtighten. Screw on coupling by hand ... to fill valve at bottom of the 5 ft (1.5 m) inlet hose ends to the coupling can result. Remove protective cap from water inlet valve. Damage to dryer fill valve and tighten coupling Using pliers, tighten the couplings with additional two-thirds turn. 3. Attach washer cold inlet hose to the coupling can result...
Installation Guide
Page 14
...to operate correctly Not Level LEVEL 2. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Adjust leveling legs Not Level Move dryer to final location, taking care not to back. Once dryer is in dryer. After dryer is level, make sure vent is clean. Repeat... secured to exhaust outlet in place, remove corner posts and cardboard from under dryer. Move dryer to final location Check levelness of dryer from front to crush or kink vent or flexible gas line. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to exhaust hood with a...
...to operate correctly Not Level LEVEL 2. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Adjust leveling legs Not Level Move dryer to final location, taking care not to back. Once dryer is in dryer. After dryer is level, make sure vent is clean. Repeat... secured to exhaust outlet in place, remove corner posts and cardboard from under dryer. Move dryer to final location Check levelness of dryer from front to crush or kink vent or flexible gas line. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to exhaust hood with a...
Installation Guide
Page 15
... parts of /recycle all parts are now installed. Electric Models q Plug into a grounded outlet. Gas Models q Plug into a grounded outlet. q Check that dryer is on . All Models: q Select a Timed Dry heated cycle, and start of your "Use and Care Guide". The odor will reduce product performance. q...; TORX is closed. Be sure vent is recommended to control the buildup of lime scale may lead to the need for leaks. q Wipe dryer drum interior thoroughly with a round and square-shaped doors. Over time, the buildup of scale through steps to remove the door. single handle ...
... parts of /recycle all parts are now installed. Electric Models q Plug into a grounded outlet. Gas Models q Plug into a grounded outlet. q Check that dryer is on . All Models: q Select a Timed Dry heated cycle, and start of your "Use and Care Guide". The odor will reduce product performance. q...; TORX is closed. Be sure vent is recommended to control the buildup of lime scale may lead to the need for leaks. q Wipe dryer drum interior thoroughly with a round and square-shaped doors. Over time, the buildup of scale through steps to remove the door. single handle ...
Installation Guide
Page 16
Remove inner door from trim ring Using a TORX® T25 screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the outer door. Then lift out the outer window and retainer up . Using a Phillips screwdriver, remove ... and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with the inside of dryer door frame, as shown. 3. A Fig. Lift off the trim ring and set aside. 16 Move the door strike 4. Remove outer window assembly from outer ...
Remove inner door from trim ring Using a TORX® T25 screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the outer door. Then lift out the outer window and retainer up . Using a Phillips screwdriver, remove ... and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with the inside of dryer door frame, as shown. 3. A Fig. Lift off the trim ring and set aside. 16 Move the door strike 4. Remove outer window assembly from outer ...
Installation Guide
Page 18
... place with the inside of the door facing up. 7. Reinstall the 10 screws securing the inner door to engage the top tab. Reinstall door on dryer Using a TORX T25 screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the...
... place with the inside of the door facing up. 7. Reinstall the 10 screws securing the inner door to engage the top tab. Reinstall door on dryer Using a TORX T25 screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the...
Installation Guide
Page 19
... outer door. Place the door on a soft towel or other non-scratch surface. Rotate the strike 180° and attach to the door frame of dryer door frame, as shown. Lift off the inner door and set aside. 4. Reverse door swing round-shaped door - Remove door from the... dryer door before proceeding. Reinstall the 4 screws in place. 19 Remove hinge and latch Latch Using a TORX T25 screwdriver, remove the 2 screws securing the door strike ...
... outer door. Place the door on a soft towel or other non-scratch surface. Rotate the strike 180° and attach to the door frame of dryer door frame, as shown. Lift off the inner door and set aside. 4. Reverse door swing round-shaped door - Remove door from the... dryer door before proceeding. Reinstall the 4 screws in place. 19 Remove hinge and latch Latch Using a TORX T25 screwdriver, remove the 2 screws securing the door strike ...
Installation Guide
Page 20
... assembly Bottom of the door facing up and out to engage the top tab. Secure in place with the 5 screws on the opposite sides from dryer Position the door with the inside of door Using a TORX T25 screwdriver, remove the 4 screws on a soft towel or other non-scratch surface. ... the door hinge to the outer door. Remove door from which they were removed. 6. Retain or set aside the 4 screws. 20 Reinstall door on dryer Using a TORX® T25 screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX screws removed earlier and the hinge assembly with the...
... assembly Bottom of the door facing up and out to engage the top tab. Secure in place with the 5 screws on the opposite sides from dryer Position the door with the inside of door Using a TORX T25 screwdriver, remove the 4 screws on a soft towel or other non-scratch surface. ... the door hinge to the outer door. Remove door from which they were removed. 6. Retain or set aside the 4 screws. 20 Reinstall door on dryer Using a TORX® T25 screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX screws removed earlier and the hinge assembly with the...