LD050P Instruction Manual
Page 1
Table of Contents Instrument Set-up 2 Introduction 2 Overview 2 Display 3 Insert batteries 3 Operations 4 Switching ON/OFF 4 Clear 4 Message Codes 4 Adjusting measuring reference 4 Distance unit setting 4 Measuring Functions 5 Measuring single distance 5 Permament measuring 5 Add / Subtract 5 Area 6 Volume 6 Pythagoras (2-point 7 Pythagoras (3-point 7 Memory (5 last results 8 Technical Data 9 Message Codes 10 Care 10 Safety Instructions 10 Areas of responsibility 10 Permitted use 11 Prohibited use 11 Hazards in use 11...
Table of Contents Instrument Set-up 2 Introduction 2 Overview 2 Display 3 Insert batteries 3 Operations 4 Switching ON/OFF 4 Clear 4 Message Codes 4 Adjusting measuring reference 4 Distance unit setting 4 Measuring Functions 5 Measuring single distance 5 Permament measuring 5 Add / Subtract 5 Area 6 Volume 6 Pythagoras (2-point 7 Pythagoras (3-point 7 Memory (5 last results 8 Technical Data 9 Message Codes 10 Care 10 Safety Instructions 10 Areas of responsibility 10 Permitted use 11 Prohibited use 11 Hazards in use 11...
LD050P Instruction Manual
Page 2
... and efficient manner. On / Measure Area / Volume / Pythagoras/ Memory Clear / Off 2 Makita LD050P Add / Subtract Measuring reference / Unit The person responsible for the first time. en Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used have the following meanings: ƽ WARNING Indicates a potentially hazardous situation or...
... and efficient manner. On / Measure Area / Volume / Pythagoras/ Memory Clear / Off 2 Makita LD050P Add / Subtract Measuring reference / Unit The person responsible for the first time. en Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used have the following meanings: ƽ WARNING Indicates a potentially hazardous situation or...
LD050P Instruction Manual
Page 3
en To ensure a reliable use, do not i use zinc-carbon batteries. Change batteries when battery symbol is flashing. Units Main line Makita LD050P 3 Instrument Set-up Display Battery Area / Volume Measuring reference Info Min/Max Measuring Addition / Subtraction Pythagoras Memory Insert batteries -+ +-
en To ensure a reliable use, do not i use zinc-carbon batteries. Change batteries when battery symbol is flashing. Units Main line Makita LD050P 3 Instrument Set-up Display Battery Area / Volume Measuring reference Info Min/Max Measuring Addition / Subtraction Pythagoras Memory Insert batteries -+ +-
LD050P Instruction Manual
Page 4
Makita LD050P Distance unit setting 2 sec Switch between the following units: 0.000m 0.00m 0.00ft 0'00'' 1/16 0.00in 0 1/16in 4 Distance is measured from the front of the device (standard setting). en Operations Switching ON/OFF 2 sec Device is measured from the rear of the device. Example: Distance is turned OFF. Adjusting measuring reference 1 Clear 1x Undo last action. 2 Message Codes If the info icon appears with a number, observe the instructions in section "Message Codes".
Makita LD050P Distance unit setting 2 sec Switch between the following units: 0.000m 0.00m 0.00ft 0'00'' 1/16 0.00in 0 1/16in 4 Distance is measured from the front of the device (standard setting). en Operations Switching ON/OFF 2 sec Device is measured from the rear of the device. Example: Distance is turned OFF. Adjusting measuring reference 1 Clear 1x Undo last action. 2 Message Codes If the info icon appears with a number, observe the instructions in section "Message Codes".
LD050P Instruction Manual
Page 5
Measuring Functions Measuring single distance 1 2 3 Aim active laser at target. 8.532 m Permament measuring 1 2 2 sec Aim active laser at high gloss surfaces. i uring to the previous one . 5.515 m 12.847 m Makita LD050P en Target surfaces: Measuring errors can occur when meas- The result is subtracted from the previous one . This process ...liquids, glass, styrofoam or semi-permeable surfaces or when aiming at target. Against dark surfaces the measuring time increases. 3 Stops permanent measuring. The same process can be used for adding or subtracting areas or volumes. 5
Measuring Functions Measuring single distance 1 2 3 Aim active laser at target. 8.532 m Permament measuring 1 2 2 sec Aim active laser at high gloss surfaces. i uring to the previous one . 5.515 m 12.847 m Makita LD050P en Target surfaces: Measuring errors can occur when meas- The result is subtracted from the previous one . This process ...liquids, glass, styrofoam or semi-permeable surfaces or when aiming at target. Against dark surfaces the measuring time increases. 3 Stops permanent measuring. The same process can be used for adding or subtracting areas or volumes. 5
LD050P Instruction Manual
Page 6
The result is 7 i shown in the main line and the measured value above. 78.694 m3 6 The result is shown in the main line and the measured 4 5 i value above. Aim laser at second target point. 24.352 m2 4 5 Aim laser at second target point. 6 Aim laser at first target point. Makita LD050P Volume 2x 1 2 3 Aim laser at third target point. en Measuring Functions Area 1x 1 2 3 Aim laser at first target point.
The result is 7 i shown in the main line and the measured value above. 78.694 m3 6 The result is shown in the main line and the measured 4 5 i value above. Aim laser at second target point. 24.352 m2 4 5 Aim laser at second target point. 6 Aim laser at first target point. Makita LD050P Volume 2x 1 2 3 Aim laser at third target point. en Measuring Functions Area 1x 1 2 3 Aim laser at first target point.
LD050P Instruction Manual
Page 7
... point. Pythagoras (3-point) 4x 1 2 3 4 5 Aim laser rectangular at rectangular point. Pressing the measuring key for 2 sec in the main line and the measured distance i above . Aim laser at lower point. 8.294 m en The result is shown in the function activates automatically Minimum or Maximum measurement. Makita LD050P 7 Pressing the measuring key for 2 sec in the main...
... point. Pythagoras (3-point) 4x 1 2 3 4 5 Aim laser rectangular at rectangular point. Pressing the measuring key for 2 sec in the main line and the measured distance i above . Aim laser at lower point. 8.294 m en The result is shown in the function activates automatically Minimum or Maximum measurement. Makita LD050P 7 Pressing the measuring key for 2 sec in the main...
LD050P Instruction Manual
Page 8
en Measuring Functions Memory (5 last results) 5x 1 2 5 5 last results are displayed. 8.294 m 5 Navigates trough 8.294 m 5 last results. 8 Makita LD050P
en Measuring Functions Memory (5 last results) 5x 1 2 5 5 last results are displayed. 8.294 m 5 Navigates trough 8.294 m 5 last results. 8 Makita LD050P
LD050P Instruction Manual
Page 9
...point 5 results Makita LD050P 9 With ...laser point at the upper or lower end of the specified temperature range. *** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. power switch...and moderate temperatures. ** unfavourable conditions are: targets with batteries) Temperature range: - Operation (ISO 16331-1) ± 2.0 mm / 0.08 ...dust- laser switch off Battery durability (2 x AAA) Dimension (H x D x W) Weight (with lower or higher reflectivity or high background illumination or temperatures at distances General Laser class Laser type Protection class Autom.
...point 5 results Makita LD050P 9 With ...laser point at the upper or lower end of the specified temperature range. *** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. power switch...and moderate temperatures. ** unfavourable conditions are: targets with batteries) Temperature range: - Operation (ISO 16331-1) ± 2.0 mm / 0.08 ...dust- laser switch off Battery durability (2 x AAA) Dimension (H x D x W) Weight (with lower or higher reflectivity or high background illumination or temperatures at distances General Laser class Laser type Protection class Autom.
LD050P Instruction Manual
Page 10
... accessories. time too long 256 Received signal too Change target surface high (e.g. en Message Codes If the message Error does not disappear after switching on the product and the instructions in the User Manual. • To be familiar with local safety regulations relating to accident prevention. • Always prevent access to them. rupted Care Safety Instructions • Clean the device with a number...
... accessories. time too long 256 Received signal too Change target surface high (e.g. en Message Codes If the message Error does not disappear after switching on the product and the instructions in the User Manual. • To be familiar with local safety regulations relating to accident prevention. • Always prevent access to them. rupted Care Safety Instructions • Clean the device with a number...
LD050P Instruction Manual
Page 11
...". Makita LD050P 11 Particularly after the instrument has been subject to abnormal use in areas permanently habitable by using ladders, when measuring near machines which are running or near parts of machines or installations which are unprotected • Aiming directly in the sun i Refer to the most stringent requirements of causing interference in other manufacturers without instruction Using outside...
...". Makita LD050P 11 Particularly after the instrument has been subject to abnormal use in areas permanently habitable by using ladders, when measuring near machines which are running or near parts of machines or installations which are unprotected • Aiming directly in the sun i Refer to the most stringent requirements of causing interference in other manufacturers without instruction Using outside...
LD050P Instruction Manual
Page 12
... may cause harmful interference to the eyes. Laser classification The device produces visible laser beams, which can radiate radio frequency energy and, if not installed and used in Hungary Batteries: 2 x AAA Complies with the instructions, may be determined by turning the equipment off and on, the user is encouraged to try to part 15 of the following measures: •...
... may cause harmful interference to the eyes. Laser classification The device produces visible laser beams, which can radiate radio frequency energy and, if not installed and used in Hungary Batteries: 2 x AAA Complies with the instructions, may be determined by turning the equipment off and on, the user is encouraged to try to part 15 of the following measures: •...
Makita LD050P Quick Start Guide
Page 1
ON 2 sec = Tracking OFF 2 sec 8.532 m -+ +- 2 sec = Units LD050P QUICKSTART 1 2 3 5 6 4 1 Display 2 On / Measure 3 Area / Volume / Pythagoras / Memory 4 Clear / OFF 5 Add / Subtract 6 Measuring reference / Unit
ON 2 sec = Tracking OFF 2 sec 8.532 m -+ +- 2 sec = Units LD050P QUICKSTART 1 2 3 5 6 4 1 Display 2 On / Measure 3 Area / Volume / Pythagoras / Memory 4 Clear / OFF 5 Add / Subtract 6 Measuring reference / Unit
Makita LD080P/LD050P New Tool Flyer English
Page 1
...: Distance, Area, Volume, Permanent, Min/Max, Add/Subtract, Pythagoras (2 point), Pythagoras (3 point) n Battery run time delivers up to change without prior notice. The Makita Teal Color is the trade dress of accessories. For a complete listing, please refer to stock on hand. Laser Distance Measure Models LD080P/ LD050P Measuring Accuracy and Productivity VERSATILITY Multiple measurement functions for increased versatility of...
...: Distance, Area, Volume, Permanent, Min/Max, Add/Subtract, Pythagoras (2 point), Pythagoras (3 point) n Battery run time delivers up to change without prior notice. The Makita Teal Color is the trade dress of accessories. For a complete listing, please refer to stock on hand. Laser Distance Measure Models LD080P/ LD050P Measuring Accuracy and Productivity VERSATILITY Multiple measurement functions for increased versatility of...