SL3000101U Installation Manual - Page 1

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR INSTALLATION MANUAL Model SL3000U SL3000101U 1 HP Single Phase SL3000103U 1 HP Three Phase SL3000501U 1/2 HP Single Phase • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. • This model is for use on vehicular passage gates ONLY and not intended for use on...
SL3000101U Installation Manual - Page 19

... and reverse upon contact with the operator to the Setup and Operation manual provided with the solid object. Place a solid object...the solid object, reduce the force setting by turning the force control slightly...installation is complete. After any adjustments are made, test the operator: 1. INSTALLATION STEP 8 INSTALL THE COVER 1. Refer to adjust the limits and complete the setup...
SL3000101U Installation Manual - Page 20

...Replace defective control board 01-37558 For complete operation and setup information refer to the Operation and Setup Manual... provided with the operator or go to control board b) Open fuse c) Defective control board a) Reset button is a normally closed circuit, or put a jumper on ", or verify that the stop circuit. BASIC TROUBLESHOOTING...
CSW200501U Setup and Operation Manual - Page 1

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC GATE OPERATORS SETUP AND OPERATION MANUAL Model SL3000U SL3000101U 1 HP Single Phase SL3000103U 1 HP Three Phase SL3000501U 1/2 HP Single Phase Model CSW200U CSW200101U 1 HP Single Phase CSW200103U 1 HP Three Phase CSW200501U 1/2 HP Single Phase LiftMaster 845 Larch Avenue Elmhurst, IL 60126-1196
CSW200501U Setup and Operation Manual - Page 2

... ERASE ALL MONITORED ENTRAPMENT PROTECTION AND VEHICLE DETECTION DEVICES.....17 SETTINGS 18 GATE OPERATOR SETUP EXAMPLES 18 DUAL GATE SETTINGS 19 WIRING 19 SAMS WIRING WITH RELAYS NOT ENERGIZED 19 FIELD WIRING 20 MAINTENANCE 21 MAINTENANCE 21 TROUBLESHOOTING 22 DIAGNOSTIC CODES 22 OPERATOR ALARM 25 ACCESSORIES 26 REPAIR PARTS 27 SL3000U 27 CSW200U 28 WARRANTY 29 1
CSW200501U Setup and Operation Manual - Page 12

OFF ON ON Energizes when motor is manually tampered with by switch settings. For an sound. For an additional audible or ... their appropriate positions. ON OFF ON Energizes if gate is manually tampered with by pushed off of relay contact activation determined by being pushed off . buzzer or light (low voltage). After servicing, set all three LED's blink 1,000,000's (e.g. 1 LED...
CSW200501U Setup and Operation Manual - Page 19

... Your specific site requirements may be different. Normal gate close (timer or control). Typically not required. Typically not required. COMMERCIAL/ GENERAL ACCESS Normally set to ...during servicing only to determine operator cycles. Tamper (Slide Gates Only) Cycle Quantity Feedback Fire Dept Open input Heater Accessory (Model HTR) RESIDENTIAL Normally set to OFF. Normally set to ...
CSW200501U Setup and Operation Manual - Page 24

..., enter limit setup mode and set limits. Disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. LiftMaster Plug-in Loop Detector only) or an open connection in the loop, or OPEN - Loop Error - Run-Distance Error Limits are not. Limit Error - Replace if defective. TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved...
CSW200501U Setup and Operation Manual - Page 30

..., to you . Some states do not allow limitations on your compliance with those instructions will be repaired or replaced (at Seller's sole option) at Seller's sole option. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE...
SL3000501U Installation Manual - Page 1

LiftMaster 845 Larch Avenue Elmhurst, IL 60126-1196 Model SL3000 ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL3000101U 1 HP Single Phase SL3000501U 1/2 HP Single Phase • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. • This model is for use on vehicular passage gates ONLY and not...
SL3000501U Installation Manual - Page 30

... Red light ON/Flash Green light OFF * For red light ON when gate is manually tampered with barrier gate). For an additional audible or visual display, connect an external ...For an sound. Not used . To determine the actual cycles that the gate operator has run (in motion). After servicing, set all three LED's blink 1,000,000's (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and ...
SL3000501U Installation Manual - Page 36

...(Model HTRNB) RESIDENTIAL Normally set to indicate if gate is manually ...set to determine operator cycles. Set to ON. Connect "Gate Close/Secure" indicator (e.g. Set to ON. For DUAL-GATE site, set to OFF. Attach alert signal (audible or visual alert system). Use during servicing only to determine operator cycles. Typically not required. Your specific site requirements may be set...
SL3000501U Installation Manual - Page 40

..., replace main control board. check for (main board) alignment or obstruction. CLOSE EYE/EDGE held more than 3 minutes (main Check OPEN EYE/EDGE input on expansion board; TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the loop. May be re-learned by saving one ) not installed. check for alignment or board) obstruction. Loop Error - Wireless...
SL3000501U Installation Manual - Page 43

...manual disconnect, manually move easily and freely through its entire range, limit to limit. Repair gate as needed. c) Ensure the gate moves at least four feet between the OPEN limit and the CLOSE limit. Replace wireless control as needed . b) Defective Exit loop detector a) Review Exit loop detector settings. b) Gate must move c) Limits are set correct limits. Repair...setup ...
SL3000501U Installation Manual - Page 47

... of shipping instructions when you may not apply to state. 45 Defective parts will be advised of this product is free from defect in its entirety. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU. This limited warranty gives you specific legal rights...

LiftMaster SL3000501U Reviews

Do you have an experience with the LiftMaster SL3000501U that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LiftMaster yet.

Ask a New Question
Use the box below to post a new question about LiftMaster SL3000501U.
Manuals / Documents
Download any of our LiftMaster SL3000501U manuals for free!

We have the following 4 documents available for the LiftMaster SL3000501U:
  • CSW200501U Setup and Operation Manual
  • SL3000501U Installation Manual
  • SL3000101U Installation Manual
  • LiftMaster Gate Operator Feature Chart Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster SL3000501U manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster SL3000501U user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.