Page 2
...Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators (Master/Second) to the Surge Suppressor Board Choosing Gate...and Trained Gate System Technicians Role of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle 1 Parts ...No part of the publisher. For Toll Free Technical Support: 1-888-ELITE-10 Release 4 01/04 1 TABLE OF CONTENTS Attention: This ...
...Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators (Master/Second) to the Surge Suppressor Board Choosing Gate...and Trained Gate System Technicians Role of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle 1 Parts ...No part of the publisher. For Toll Free Technical Support: 1-888-ELITE-10 Release 4 01/04 1 TABLE OF CONTENTS Attention: This ...
MIRACLE ONE Manual
Page 9
...Caution - READ AND FOLLOW ALL INSTRUCTIONS. 2. SAVE THESE INSTRUCTIONS. 8 DO NOT install on ANY pedestrian gates. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. DO NOT install on a few pickets, they will cause the wires to sprinklers or any area... "Timer" is completely closed. Elite Access Systems, Inc. To reduce the risk of the gate operator. IMPORTANT SAFETY INSTRUCTIONS WARNING - Have a qualified service person periodically inspect and make repairs to persons, The Miracle-1 is not responsible for Vehicular Gate use ONLY! DO NOT install ...
...Caution - READ AND FOLLOW ALL INSTRUCTIONS. 2. SAVE THESE INSTRUCTIONS. 8 DO NOT install on ANY pedestrian gates. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. DO NOT install on a few pickets, they will cause the wires to sprinklers or any area... "Timer" is completely closed. Elite Access Systems, Inc. To reduce the risk of the gate operator. IMPORTANT SAFETY INSTRUCTIONS WARNING - Have a qualified service person periodically inspect and make repairs to persons, The Miracle-1 is not responsible for Vehicular Gate use ONLY! DO NOT install ...
MIRACLE ONE Manual
Page 20
...GROUND ROD INSTALLATION Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from the gate operator. Without this path, the intense energy generated by lightning could be located within 3 feet from which to dissipate its integrity, replace it , or... most cases. Use the proper type earth ground rod for your area. 8 Ft The ground wire must be directed towards the Elite gate operator. Connect ground wire to green wire from surge suppressor board Use 12 gauge ground wire Before digging more than 18" deep, contact ...
...GROUND ROD INSTALLATION Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from the gate operator. Without this path, the intense energy generated by lightning could be located within 3 feet from which to dissipate its integrity, replace it , or... most cases. Use the proper type earth ground rod for your area. 8 Ft The ground wire must be directed towards the Elite gate operator. Connect ground wire to green wire from surge suppressor board Use 12 gauge ground wire Before digging more than 18" deep, contact ...
MIRACLE ONE Manual
Page 23
... bigger than 18 ft, then D must have enough separation between loop and gate when opened or closed. This is largest. For toll free technical support: 1-888-ELITE-10 22 SINGLE OPERATOR LOOP SIZE AND PLACEMENT It is VERY important to have enough space between loops... and gates to scale Exit Loop Inside H Safety Loop F I which ever is for a typical single Miracle 1 loop installation. Exit Loop H = G or...
... bigger than 18 ft, then D must have enough separation between loop and gate when opened or closed. This is largest. For toll free technical support: 1-888-ELITE-10 22 SINGLE OPERATOR LOOP SIZE AND PLACEMENT It is VERY important to have enough space between loops... and gates to scale Exit Loop Inside H Safety Loop F I which ever is for a typical single Miracle 1 loop installation. Exit Loop H = G or...
MIRACLE ONE Manual
Page 26
...Terminal Connectors 17 18 19 20 21 22 23 24 25 26 27 Surge Suppressor Elite Part # A 24 Com N.O. Center Loop Allows gate to stay open when vehicles are obstructing gate path. Gnd +24V 23 25 For fail safe operation, connect safety loops in series. CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO +24... 24 25 26 27 Surge Suppressor Removable Terminal Connectors 17 18 19 20 21 22 23 24 25 26 27 Surge Suppressor Elite Part # A 24 19 20 Com N.O. Gnd +24V 23 25 Elite Part # A 24 17 18 Com N.O. LOOP DETECTOR WIRING Safety Loop Allows gate to stay open for exiting vehicles. 25
...Terminal Connectors 17 18 19 20 21 22 23 24 25 26 27 Surge Suppressor Elite Part # A 24 Com N.O. Center Loop Allows gate to stay open when vehicles are obstructing gate path. Gnd +24V 23 25 For fail safe operation, connect safety loops in series. CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO +24... 24 25 26 27 Surge Suppressor Removable Terminal Connectors 17 18 19 20 21 22 23 24 25 26 27 Surge Suppressor Elite Part # A 24 19 20 Com N.O. Gnd +24V 23 25 Elite Part # A 24 17 18 Com N.O. LOOP DETECTOR WIRING Safety Loop Allows gate to stay open for exiting vehicles. 25
MIRACLE ONE Manual
Page 27
... provided with the revised UL 325 intended to be used , all of the photo beam sensors are being used in class I or class II gate operator, like the following: OMRON Retro-Reflective Photocell, Model: E3K-R10K4-NR BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO ...+24 VOLT +24 VAC INPUT 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Elite Part # A OMRON Important! Gate in Closed Position Photocell Gate in Open Position Potential Entrapment Area (Shaded) Less than 18" from a wall or any other object or potential entrapment installation...
... provided with the revised UL 325 intended to be used , all of the photo beam sensors are being used in class I or class II gate operator, like the following: OMRON Retro-Reflective Photocell, Model: E3K-R10K4-NR BURGLAR ALARM INPUT UL SENSOR CENTER LOOP SAFETY LOOP STRIKE INPUT GROUND RADIO ...+24 VOLT +24 VAC INPUT 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Elite Part # A OMRON Important! Gate in Closed Position Photocell Gate in Open Position Potential Entrapment Area (Shaded) Less than 18" from a wall or any other object or potential entrapment installation...
MIRACLE ONE Manual
Page 38
TROUBLESHOOTING Check the Fuses If the gate is not moving in any direction be sure to check all LED's on the board are on, change the corresponding fuse on a regular basis, make sure operator is blowing on the right side of the board. Master / Slave Change Fuse 15 Amps 3 Amps 1.5 ...Amps Caution: If left side of the LED displays on the control board. Check motor wire connections. Replace the fuses only with specified rating (Supplied by Chamberlain Elite). Single Change ...
TROUBLESHOOTING Check the Fuses If the gate is not moving in any direction be sure to check all LED's on the board are on, change the corresponding fuse on a regular basis, make sure operator is blowing on the right side of the board. Master / Slave Change Fuse 15 Amps 3 Amps 1.5 ...Amps Caution: If left side of the LED displays on the control board. Check motor wire connections. Replace the fuses only with specified rating (Supplied by Chamberlain Elite). Single Change ...
MIRACLE ONE Manual
Page 40
For Toll Free Technical Support: 1-888-ELITE-10 SYSOTNEM RSEEVNESROSRE SAELNASROMR Vertical Gate Level line Horizontal Gate Level line Incorrect Installation 1 The gate is too heavy or the operator or gate is installed incorrectly. 2 A foreign object is on the gate frame while the gate is moving. 3 Gate hinges are too tight or broken and the gate is not moving freely. 4 The gate hits the driveway, curb or other, and gets stuck in an awkward position. 39 TROUBLESHOOTING You will SEE the alarm LED "ON" when...
For Toll Free Technical Support: 1-888-ELITE-10 SYSOTNEM RSEEVNESROSRE SAELNASROMR Vertical Gate Level line Horizontal Gate Level line Incorrect Installation 1 The gate is too heavy or the operator or gate is installed incorrectly. 2 A foreign object is on the gate frame while the gate is moving. 3 Gate hinges are too tight or broken and the gate is not moving freely. 4 The gate hits the driveway, curb or other, and gets stuck in an awkward position. 39 TROUBLESHOOTING You will SEE the alarm LED "ON" when...
MIRACLE ONE Manual
Page 44
... swing gate operator is designed to be performed by an authorized service technician. 43 For Toll Free Technical Support: 1-888-ELITE-10 (1-888-354-8310) Important: Any service must be very low in good conditions. Harness-Motor (Operator Cord) Q300 - Arm End Caps (Set) Q303 - DC Solar Power Adapter O-MIRACLE 1 ARM - Control Board (Single Operator) Q223...
... swing gate operator is designed to be performed by an authorized service technician. 43 For Toll Free Technical Support: 1-888-ELITE-10 (1-888-354-8310) Important: Any service must be very low in good conditions. Harness-Motor (Operator Cord) Q300 - Arm End Caps (Set) Q303 - DC Solar Power Adapter O-MIRACLE 1 ARM - Control Board (Single Operator) Q223...