LA500UL Wiring Diagram
Page 1
... 51 Pass-point not detected (Arm 1) 52 Pass-point not detected (Arm 2) Check yellow pass-point wiring. WIRING DIAGRAM Model LA500UL To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. • Replace ... the code sequence number is NOT a single 12V battery on main control board; CODE COLOR KEY: LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection CODE MEANING SOLUTION Main control board has experienced an internal Disconnect all power, wait 15 seconds, then ...
... 51 Pass-point not detected (Arm 1) 52 Pass-point not detected (Arm 2) Check yellow pass-point wiring. WIRING DIAGRAM Model LA500UL To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. • Replace ... the code sequence number is NOT a single 12V battery on main control board; CODE COLOR KEY: LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection CODE MEANING SOLUTION Main control board has experienced an internal Disconnect all power, wait 15 seconds, then ...
Installation Manual
Page 2
... and Force Adjustment 22 Obstruction Test 24 PROGRAMMING 25 Remote Controls (Not Provided 25 LiftMaster Internet Gateway (Not Provided 26 Erase All Codes 26 Erase Limits 26 To Remove and Erase Monitored Entrapment Protection Devices...........26 OPERATION 27 Gate Operator Setup Examples 27 Control Board Overview 28 Manual Release 29 Reset Button 29 Party...
... and Force Adjustment 22 Obstruction Test 24 PROGRAMMING 25 Remote Controls (Not Provided 25 LiftMaster Internet Gateway (Not Provided 26 Erase All Codes 26 Erase Limits 26 To Remove and Erase Monitored Entrapment Protection Devices...........26 OPERATION 27 Gate Operator Setup Examples 27 Control Board Overview 28 Manual Release 29 Reset Button 29 Party...
Installation Manual
Page 12
... the knockouts using a screwdriver and hammer. 5. Make sure the U-bolts do not protrude more than 3/4 inch from the expansion board. 3. Disconnect the "Main Board" connector from the control box because this can short the control board. 6. Select the mounting holes (according to mounting surface. Post: Use U-bolts and rubber washers (not provided) to the expansion...
... the knockouts using a screwdriver and hammer. 5. Make sure the U-bolts do not protrude more than 3/4 inch from the expansion board. 3. Disconnect the "Main Board" connector from the control box because this can short the control board. 6. Select the mounting holes (according to mounting surface. Post: Use U-bolts and rubber washers (not provided) to the expansion...
Installation Manual
Page 14
The location of the power disconnect should be on the control board as shown. 7. Operator labeled. MUST be a single, whole...5. Connect the operator cable wires to the connector according to the colored label on a l ALL power and control wiring MUST be performed until disconnecting the electrical power (AC l DO NOT install ANY wiring or attempt to lightning...the operator cable through the provided watertight connector. 3. Run wire from the earth ground rod to the Control Board 1. INSTALLATION To reduce the risk of SEVERE INJURY or DEATH: l ANY maintenance to page 18. The...
The location of the power disconnect should be on the control board as shown. 7. Operator labeled. MUST be a single, whole...5. Connect the operator cable wires to the connector according to the colored label on a l ALL power and control wiring MUST be performed until disconnecting the electrical power (AC l DO NOT install ANY wiring or attempt to lightning...the operator cable through the provided watertight connector. 3. Run wire from the earth ground rod to the Control Board 1. INSTALLATION To reduce the risk of SEVERE INJURY or DEATH: l ANY maintenance to page 18. The...
Installation Manual
Page 17
... lock, for example. This gate is no appropriate location on that the control box be the first to Gate 1 connections on the outside of the control box. 2. The BIPART DELAY switch on the control board needs to be connected to close from the close second. If there is...gate. The illustration shows a dual gate configuration with the BIPART DELAY switch ON will need to open limit. The control box with a decorative overlapping piece on the control board. Insert the extension cable and watertight connector into the GATE 2 terminal on the connector (white to white, red...
... lock, for example. This gate is no appropriate location on that the control box be the first to Gate 1 connections on the outside of the control box. 2. The BIPART DELAY switch on the control board needs to be connected to close from the close second. If there is...gate. The illustration shows a dual gate configuration with the BIPART DELAY switch ON will need to open limit. The control box with a decorative overlapping piece on the control board. Insert the extension cable and watertight connector into the GATE 2 terminal on the connector (white to white, red...
Installation Manual
Page 19
... photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be disregarded during gate closing . Control Board CLOSES EYES/INTERRUPT (2 Terminals) The CLOSE EYES/INTERRUPT input is sensed during gate opening . This input will reverse to the expansion... board. EYE ONLY and COM Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to ...
... photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be disregarded during gate closing . Control Board CLOSES EYES/INTERRUPT (2 Terminals) The CLOSE EYES/INTERRUPT input is sensed during gate opening . This input will reverse to the expansion... board. EYE ONLY and COM Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to ...
Installation Manual
Page 20
... or 240 Vac. Ensure the wires are charged in separate conduits. NOTE: You may see a small spark when plugging the J15 plug into the control board. OPERATOR POWER SOURCE 120 VAC Wire Gauge 14 350 feet (107 m) Wire Gauge 12 525 feet (160 m) Wire Gauge 10 850 feet (259... Wire Gauge 10 2,950 feet (899 m) NOTE: Use copper conductors ONLY. Connect the black wire from the main power source circuit breaker. 2. The control board will power up and out. 4. The batteries are not pinched. 9. Run the AC power wires to the ground screw on your application. Connect the ground...
... or 240 Vac. Ensure the wires are charged in separate conduits. NOTE: You may see a small spark when plugging the J15 plug into the control board. OPERATOR POWER SOURCE 120 VAC Wire Gauge 14 350 feet (107 m) Wire Gauge 12 525 feet (160 m) Wire Gauge 10 850 feet (259... Wire Gauge 10 2,950 feet (899 m) NOTE: Use copper conductors ONLY. Connect the black wire from the main power source circuit breaker. 2. The control board will power up and out. 4. The batteries are not pinched. 9. Run the AC power wires to the ground screw on your application. Connect the ground...
Installation Manual
Page 21
...section in the Appendix. 1. NOTE: You may see a small spark when plugging the J15 plug into the control board. Turn ON AC power. INSTALLATION Large Metal Control Box To use solar panels with equivalent or better electrical, mechanical, and flammability ratings. 21 Factory default is ...connected to the ground screw on your application. Connect the white wire from the control board. 2. Ensure the wires are not pinched. 10. The control board will power up and out. 5. Remove the toroid assembly from the main power source circuit breaker. 3. Connect...
...section in the Appendix. 1. NOTE: You may see a small spark when plugging the J15 plug into the control board. Turn ON AC power. INSTALLATION Large Metal Control Box To use solar panels with equivalent or better electrical, mechanical, and flammability ratings. 21 Factory default is ...connected to the ground screw on your application. Connect the white wire from the control board. 2. Ensure the wires are not pinched. 10. The control board will power up and out. 5. Remove the toroid assembly from the main power source circuit breaker. 3. Connect...
Installation Manual
Page 22
...of SEVERE INJURY or DEATH: l Without a properly installed safety reversal system, persons (particularly small children) could be installed on the control board (refer to Fine Tune the Force section) to compensate for environmental changes. Turn the release lever clockwise 180° back to move ...in the open and close position. This locks the release lever. The operator is designed with a Remote Control in plain view. l Too much force on the control board will interfere with an object. l NEVER increase force beyond minimum amount required to the engaged position. ...
...of SEVERE INJURY or DEATH: l Without a properly installed safety reversal system, persons (particularly small children) could be installed on the control board (refer to Fine Tune the Force section) to compensate for environmental changes. Turn the release lever clockwise 180° back to move ...in the open and close position. This locks the release lever. The operator is designed with a Remote Control in plain view. l Too much force on the control board will interfere with an object. l NEVER increase force beyond minimum amount required to the engaged position. ...
Installation Manual
Page 23
... the TEST BUTTONS. This automatically sets the force. 8. Press and release the SET CLOSE or SET OPEN button depending on the secondary gate first the control board will exit limit setting mode.* 7. If a mistake is being set . 5. Press and release the SET CLOSE or SET OPEN button depending on the primary gate...
... the TEST BUTTONS. This automatically sets the force. 8. Press and release the SET CLOSE or SET OPEN button depending on the secondary gate first the control board will exit limit setting mode.* 7. If a mistake is being set . 5. Press and release the SET CLOSE or SET OPEN button depending on the primary gate...
Installation Manual
Page 24
...test for fine tuning the force where wind or environmental changes may be adjusted independently from the other by turning the force control slightly counter-clockwise. The force setting is stopping at the factory. Open and close limits, but low enough to prevent serious...Obstruction Test" after any external entrapment protection devices will not reverse by turning the force control slightly clockwise. 3. The REVERSAL FORCE DIAL is equipped with an object. 4. Based on the control board is used for the open direction. Make sure that any adjustments are set to ...
...test for fine tuning the force where wind or environmental changes may be adjusted independently from the other by turning the force control slightly counter-clockwise. The force setting is stopping at the factory. Open and close limits, but low enough to prevent serious...Obstruction Test" after any external entrapment protection devices will not reverse by turning the force control slightly clockwise. 3. The REVERSAL FORCE DIAL is equipped with an object. 4. Based on the control board is used for the open direction. Make sure that any adjustments are set to ...
Installation Manual
Page 26
Using the reset button on the opertaor's control board 1. Register the LiftMaster Internet Gateway. 5. The LiftMaster Internet Gateway will beep if programming is within range and the operator will stay in learn mode for three minutes. 6. The LiftMaster Internet Gateway will pair to the operator if... 3. Press the Learn button twice on the primary operator (the operator will beep as shown by the LiftMaster Internet Gateway app will be controlled through the LiftMaster Internet Gateway app. Within 30 seconds, when the gate is closed ". Erase All Codes 1. Press and...
Using the reset button on the opertaor's control board 1. Register the LiftMaster Internet Gateway. 5. The LiftMaster Internet Gateway will beep if programming is within range and the operator will stay in learn mode for three minutes. 6. The LiftMaster Internet Gateway will pair to the operator if... 3. Press the Learn button twice on the primary operator (the operator will beep as shown by the LiftMaster Internet Gateway app will be controlled through the LiftMaster Internet Gateway app. Within 30 seconds, when the gate is closed ". Erase All Codes 1. Press and...
Installation Manual
Page 28
...is less than 23 V 5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is reset by a "50" which indicates the operator type as LA500UL. See Force Adjustment section. 9 TEST BUTTONS: The TEST BUTTONS will either open until AC power is in the Troubleshooting section. The firmware version ...or close the gate when the operator is restored or battery voltage increases. NOTE: Any radio command, single button control, or CLOSE command on the control board prior to open controls, loops, close edges, and close the gate after the operator type, example "1.2". 28 The operator type will ...
...is less than 23 V 5 BIPART DELAY Switch: The LOCK/BIPART DELAY switch is reset by a "50" which indicates the operator type as LA500UL. See Force Adjustment section. 9 TEST BUTTONS: The TEST BUTTONS will either open until AC power is in the Troubleshooting section. The firmware version ...or close the gate when the operator is restored or battery voltage increases. NOTE: Any radio command, single button control, or CLOSE command on the control board prior to open controls, loops, close edges, and close the gate after the operator type, example "1.2". 28 The operator type will ...
Installation Manual
Page 33
... SBC, OPN, CLS, and STP inputs. 5. restored (enabling the Timer-to -Close). EXIT FAIL switch: the main control board firmware revision is activated it causes a closing 9. MAIN BOARD input: Input Connection for the Wireless Edge Kit (Model LMWEKITU) 33 ON: When CLOSE EYES/Interrupt loop is displayed. Loop...DC power to close (ignores the Timer-to -Close). 2. Connect power. Once the vehicle is clear the gate will continue to the main control board for example: For version 5.1 when the green POWER LED is solid the LED 1 will cause the gate to the AUX relay contact terminal ...
... SBC, OPN, CLS, and STP inputs. 5. restored (enabling the Timer-to -Close). EXIT FAIL switch: the main control board firmware revision is activated it causes a closing 9. MAIN BOARD input: Input Connection for the Wireless Edge Kit (Model LMWEKITU) 33 ON: When CLOSE EYES/Interrupt loop is displayed. Loop...DC power to close (ignores the Timer-to -Close). 2. Connect power. Once the vehicle is clear the gate will continue to the main control board for example: For version 5.1 when the green POWER LED is solid the LED 1 will cause the gate to the AUX relay contact terminal ...
Installation Manual
Page 34
... Cycle count is between 1,000 and 9,999,000 cycles. Cycle count displayed is 163,000.). After servicing, set switch 1 on the control board). RED/GREEN LIGHT FUNCTIONALITY Red light wired to conserve battery power. Energizes 3 seconds before gate motion and remains energized during gate motion. cutoff...or solar power is manually tampered with by switch settings. The onboard alarm will turn on battery power. EXPANSION BOARD Auxiliary Relays 1 and 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for 10 seconds then turn off.
... Cycle count is between 1,000 and 9,999,000 cycles. Cycle count displayed is 163,000.). After servicing, set switch 1 on the control board). RED/GREEN LIGHT FUNCTIONALITY Red light wired to conserve battery power. Energizes 3 seconds before gate motion and remains energized during gate motion. cutoff...or solar power is manually tampered with by switch settings. The onboard alarm will turn on battery power. EXPANSION BOARD Auxiliary Relays 1 and 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for 10 seconds then turn off.
Installation Manual
Page 36
... gloves and eye protection when changing the battery or working around the battery compartment. Use only LiftMaster part 29-NP712 for vehicles ONLY. The standard control box comes with gate controls. cleared and secured, at that the incoming voltage to adjust and retest the gate operator properly...gate travel , retest the gate operator. Read the owner's manual. national and local electrical codes. ALWAYS disconnect the batteries to the control board and DOES NOT turn off battery power. The batteries contain lead and need to be with ASTM F2200, see page 5 Check ...
... gloves and eye protection when changing the battery or working around the battery compartment. Use only LiftMaster part 29-NP712 for vehicles ONLY. The standard control box comes with gate controls. cleared and secured, at that the incoming voltage to adjust and retest the gate operator properly...gate travel , retest the gate operator. Read the owner's manual. national and local electrical codes. ALWAYS disconnect the batteries to the control board and DOES NOT turn off battery power. The batteries contain lead and need to be with ASTM F2200, see page 5 Check ...
Installation Manual
Page 37
Press and release the STOP button to the control board, it is recommended that you unplug the J15 plug. To View the Codes The codes will also time out after two minutes of inactivity. The ...
Press and release the STOP button to the control board, it is recommended that you unplug the J15 plug. To View the Codes The codes will also time out after two minutes of inactivity. The ...
Installation Manual
Page 38
... then disappear. LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection Code 31 32 33 35 36 37 38 39 40 41 42 43 44 45 46 51 52 53 54 60 61 62 63 64 65 66 67 68 Meaning Main control board has experienced an... a 12V system. LiftMaster Plug-in . AC/DC board supply dipped below allowable level. Check wiring and connections. Check wired input for alignment or obstruction. Failure or missing loop (SHORT or OPEN - If rebooting, ensure enough time for alignment or obstruction. If issue continues, replace main control board. If so, erase...
... then disappear. LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection Code 31 32 33 35 36 37 38 39 40 41 42 43 44 45 46 51 52 53 54 60 61 62 63 64 65 66 67 68 Meaning Main control board has experienced an... a 12V system. LiftMaster Plug-in . AC/DC board supply dipped below allowable level. Check wiring and connections. Check wired input for alignment or obstruction. Failure or missing loop (SHORT or OPEN - If rebooting, ensure enough time for alignment or obstruction. If issue continues, replace main control board. If so, erase...
Installation Manual
Page 39
If an obstruction did NOT occur, check inputs and wiring. Check inputs and communication method between the main board and the expansion board. See section on main control board IF an obstruction occurred, no obstruction, check that the mechanical assembly is engaged and free to erase the wireless ... YES 39 Make sure connected devices are not supported. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. IF an obstruction occurred, no action required. May have to move . If no obstruction, check the operator wiring and that the ...
If an obstruction did NOT occur, check inputs and wiring. Check inputs and communication method between the main board and the expansion board. See section on main control board IF an obstruction occurred, no obstruction, check that the mechanical assembly is engaged and free to erase the wireless ... YES 39 Make sure connected devices are not supported. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. IF an obstruction occurred, no action required. May have to move . If no obstruction, check the operator wiring and that the ...
Installation Manual
Page 40
TROUBLESHOOTING Control Board LEDs INPUT POWER BATT CHARGING TIMER STATUS LEDS OFF OFF state ON AC charger or Solar power available OFF Not charging ON Three stage battery ...
TROUBLESHOOTING Control Board LEDs INPUT POWER BATT CHARGING TIMER STATUS LEDS OFF OFF state ON AC charger or Solar power available OFF Not charging ON Three stage battery ...