"Manufacturer's Certification for Credit" Manual
Page 1
... / Residential DC Linear Actuator (Single Gate Model LA5001PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear Actuator (Dual Gate Model LA500-2PKGDC) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412-1PKG) LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412-2PKG) LiftMaster SW425DCSP3 Solar Gate Operator System LiftMaster RSL12V Residential DC Slide Gate Operator System (Single...
... / Residential DC Linear Actuator (Single Gate Model LA5001PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear Actuator (Dual Gate Model LA500-2PKGDC) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412-1PKG) LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412-2PKG) LiftMaster SW425DCSP3 Solar Gate Operator System LiftMaster RSL12V Residential DC Slide Gate Operator System (Single...
DC Gate Operators Overview Brochure Manual
Page 1
... to 126 days standby time Yes Approx. 59 cycles per day (10W Solar Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear...* 3 Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby time Yes...
... to 126 days standby time Yes Approx. 59 cycles per day (10W Solar Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear...* 3 Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby time Yes...
DC Gate Operators Overview Brochure Manual
Page 2
...Wiring Options, simply 'plug-in' your selection for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Switch on/off of closed position quickly securing property. • Fire ...easily identified to exit property or interrupt gate travel if a vehicle is forced off devices at all other times to maximize solar performance. • Common Control Board User Interface simplifies installation and troubleshooting. • Diagnostic 2 Digit LED Display speeds installation...
...Wiring Options, simply 'plug-in' your selection for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Switch on/off of closed position quickly securing property. • Fire ...easily identified to exit property or interrupt gate travel if a vehicle is forced off devices at all other times to maximize solar performance. • Common Control Board User Interface simplifies installation and troubleshooting. • Diagnostic 2 Digit LED Display speeds installation...
CSL24VDC Sell Sheet Manual
Page 1
... Unrivaled Performance, Security and Accessibility Engineered for more than a million cycles in high-traffic heavy-duty applications, the CSL24VDC is ideal for the most demanding slide gate environments. With MyQ® Technology you can monitor and control your ...protected with its path. • Safety Inputs are provided for applications requiring a large number of mind. Solar Panel (SOLPNL10W12V) Solar option available. OPTIONAL ACCESSORIES: LiftMaster Internet Gateway (828LM)*** Receive alerts or monitor and activate gate via an Internet-enabled device anywhere in quickly...
... Unrivaled Performance, Security and Accessibility Engineered for more than a million cycles in high-traffic heavy-duty applications, the CSL24VDC is ideal for the most demanding slide gate environments. With MyQ® Technology you can monitor and control your ...protected with its path. • Safety Inputs are provided for applications requiring a large number of mind. Solar Panel (SOLPNL10W12V) Solar option available. OPTIONAL ACCESSORIES: LiftMaster Internet Gateway (828LM)*** Receive alerts or monitor and activate gate via an Internet-enabled device anywhere in quickly...
CSL24VDC Sell Sheet Manual
Page 2
CSL24VDC COMMERCIAL HIGH TRAFFIC DC SLIDE GATE OPERATOR FEATURES FIRE ...piece cover for dual-gate communication. MyQ Technology communication can be added to closed position quickly securing property. LiftMaster gate operators comply with 1/4" gold zinc plated steel for rust prevention. PRE-MOTION WARNING ALARM Selectable feature ...the right to extend cycles and standby time on battery backup. **Power efficient LiftMaster design saves power when running on battery or solar mode. ***LiftMaster® Internet Gateway Accessory functionality is dependent on /off devices at all times,...
CSL24VDC COMMERCIAL HIGH TRAFFIC DC SLIDE GATE OPERATOR FEATURES FIRE ...piece cover for dual-gate communication. MyQ Technology communication can be added to closed position quickly securing property. LiftMaster gate operators comply with 1/4" gold zinc plated steel for rust prevention. PRE-MOTION WARNING ALARM Selectable feature ...the right to extend cycles and standby time on battery backup. **Power efficient LiftMaster design saves power when running on battery or solar mode. ***LiftMaster® Internet Gateway Accessory functionality is dependent on /off devices at all times,...
CSL24VDC Solar Chart Manual
Page 1
... the gate operator via batteries. LiftMaster® Solar Gate Cycles per Day Reference Guide The LiftMaster Gate Operator Solar Gate Access utilizes best in class power management system to deliver power when needed most for the entire day. Power is due to ensure proper operation. LA500DC LA412DC LA400DC CSW24VDC CSL24VDC RSW12VDC RSL12VDC The batteries are...
... the gate operator via batteries. LiftMaster® Solar Gate Cycles per Day Reference Guide The LiftMaster Gate Operator Solar Gate Access utilizes best in class power management system to deliver power when needed most for the entire day. Power is due to ensure proper operation. LA500DC LA412DC LA400DC CSW24VDC CSL24VDC RSW12VDC RSL12VDC The batteries are...
CSL24VDC Solar Chart Manual
Page 2
... 16 11 14 #NUM! 1 #NUM! #NUM! 35 51 30 45 27 42 #NUM! #NUM! 2 #NUM! * Not currently offered in power draw for solar daily cycles are representative of wired dual gate installation. If your installation is a wireless dual gate setup use single gate cycle estimate and add in...! 3 #NUM! 66 120 57 111 53 106 #NUM! #NUM! 35 #NUM! System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop detector LOOPDETLM (up current draw by control...
... 16 11 14 #NUM! 1 #NUM! #NUM! 35 51 30 45 27 42 #NUM! #NUM! 2 #NUM! * Not currently offered in power draw for solar daily cycles are representative of wired dual gate installation. If your installation is a wireless dual gate setup use single gate cycle estimate and add in...! 3 #NUM! 66 120 57 111 53 106 #NUM! #NUM! 35 #NUM! System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop detector LOOPDETLM (up current draw by control...
CSL24VDC Solar Chart Manual
Page 3
System voltage 12v Main board with no radios learned (mA) 4.2 One or more LiftMaster® transmitters learned (mA) +1.5 MyQ® device or wireless dual gate learned (mA) +3.9 Expansion board (mA) +18.5 Per loop detector LOOPDETLM (up current... manual. 3 not available 2 3 1 2 1 Add up to 3 loop detectors can be 25 (3) 10W 12V panels in to the expansion board) (mA) +6.6 LA412DC Single gate solar cycles per day * Zone 1 (6 Hrs Sunlight/Day) Zone 2 (4 Hrs Sunlight/Day) Zone 3 (2 Hrs Sunlight/Day) 7AH batteries 33AH battery 7AH batteries 33AH battery 7AH batteries...
System voltage 12v Main board with no radios learned (mA) 4.2 One or more LiftMaster® transmitters learned (mA) +1.5 MyQ® device or wireless dual gate learned (mA) +3.9 Expansion board (mA) +18.5 Per loop detector LOOPDETLM (up current... manual. 3 not available 2 3 1 2 1 Add up to 3 loop detectors can be 25 (3) 10W 12V panels in to the expansion board) (mA) +6.6 LA412DC Single gate solar cycles per day * Zone 1 (6 Hrs Sunlight/Day) Zone 2 (4 Hrs Sunlight/Day) Zone 3 (2 Hrs Sunlight/Day) 7AH batteries 33AH battery 7AH batteries 33AH battery 7AH batteries...
CSL24VDC Solar Chart Manual
Page 4
...50 50 50 50 50 50 50 50 50 parallel 100 33 48 50 200 8 20 27 6 30W Solar Panel Note: 30W would be 25 (3) 10W 12V panels in 30 50 50 50 50 50 50 50 50...#NUM! #NUM! 7 #NUM! 13 #NUM! System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop detector ... 50 50 50 50 50 50 50 50 parallel 100 42 50 50 200 10 25 34 6 30W Solar Panel Note: 30W would be 25 (3) 10W 12V panels in 30 50 50 50 50 50 50 50...
...50 50 50 50 50 50 50 50 50 parallel 100 33 48 50 200 8 20 27 6 30W Solar Panel Note: 30W would be 25 (3) 10W 12V panels in 30 50 50 50 50 50 50 50 50...#NUM! #NUM! 7 #NUM! 13 #NUM! System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop detector ... 50 50 50 50 50 50 50 50 parallel 100 42 50 50 200 10 25 34 6 30W Solar Panel Note: 30W would be 25 (3) 10W 12V panels in 30 50 50 50 50 50 50 50...
CSL24VDC Solar Chart Manual
Page 5
... feature 24v (CSW24VDC, CSL24VDC) configurations. CSW24VDC / CSL24VDC Current consumption by feature and accessory to the expansion board) (mA) 24v 2.7 +1 +2.4 +11.1 +3.8 * Estimated based on use with LiftMaster transmitters CSW 24VDC Gate solar cycles per day Battery current draw (mA) 5 10W* Solar Panel 15 NOTE: Must Use 24V 20 Solar Panel 40 60 5 20W Solar Panel NOTE:20W would...
... feature 24v (CSW24VDC, CSL24VDC) configurations. CSW24VDC / CSL24VDC Current consumption by feature and accessory to the expansion board) (mA) 24v 2.7 +1 +2.4 +11.1 +3.8 * Estimated based on use with LiftMaster transmitters CSW 24VDC Gate solar cycles per day Battery current draw (mA) 5 10W* Solar Panel 15 NOTE: Must Use 24V 20 Solar Panel 40 60 5 20W Solar Panel NOTE:20W would...
CSL24VDC Solar Chart Manual
Page 6
This is due to the effect of cold weather on solar installations, please contact LiftMaster Technical Support 800.528.6563 © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTSLGD 6/14 Optional power supply with 33-AH batteries recommended ... ((2) 33-AH batteries not included) CSW24VDC, CSL24VDC (2) 33-AH batteries recommended in lieu of standard 7-AH batteries RSW12VDC, RSL12VDC (1) 33-AH batteries recommended in climates where temperatures reach below 32°F. Solar Applications are not supported in lieu of standard ...
This is due to the effect of cold weather on solar installations, please contact LiftMaster Technical Support 800.528.6563 © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTSLGD 6/14 Optional power supply with 33-AH batteries recommended ... ((2) 33-AH batteries not included) CSW24VDC, CSL24VDC (2) 33-AH batteries recommended in lieu of standard 7-AH batteries RSW12VDC, RSL12VDC (1) 33-AH batteries recommended in climates where temperatures reach below 32°F. Solar Applications are not supported in lieu of standard ...
CSL24VDC Installation Manual
Page 3
...DUAL GATES ONLY 17 INSTALL THE COVER 19 ADJUSTMENT 20 LIMIT AND FORCE ADJUSTMENT 20 PROGRAMMING 22 REMOTE CONTROLS (NOT PROVIDED 22 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 23 ERASE ALL CODES 23 ERASE LIMITS 23 TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION DEVICES 23 ... 36 TROUBLESHOOTING CHART 37 APPENDIX 40 TYPES OF INSTALLATIONS 40 DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR.........41 ATTACH THE CHAIN 41 SOLAR PANEL(S 42 SAMS WIRING WITH RELAYS NOT ENERGIZED 46 DUAL GATE SETTINGS 46 LIMIT SETUP WITH A REMOTE CONTROL 47 WIRING DIAGRAM...
...DUAL GATES ONLY 17 INSTALL THE COVER 19 ADJUSTMENT 20 LIMIT AND FORCE ADJUSTMENT 20 PROGRAMMING 22 REMOTE CONTROLS (NOT PROVIDED 22 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 23 ERASE ALL CODES 23 ERASE LIMITS 23 TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION DEVICES 23 ... 36 TROUBLESHOOTING CHART 37 APPENDIX 40 TYPES OF INSTALLATIONS 40 DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR.........41 ATTACH THE CHAIN 41 SOLAR PANEL(S 42 SAMS WIRING WITH RELAYS NOT ENERGIZED 46 DUAL GATE SETTINGS 46 LIMIT SETUP WITH A REMOTE CONTROL 47 WIRING DIAGRAM...
CSL24VDC Installation Manual
Page 8
...;C (-40°F to 2 edge sensors 21.1" 20" 14.6" 6 for use in vehicular slide gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum Duty Cycle Operating...
...;C (-40°F to 2 edge sensors 21.1" 20" 14.6" 6 for use in vehicular slide gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum Duty Cycle Operating...
CSL24VDC Installation Manual
Page 16
... on a separate fused line of adequate capacity. • ALL electrical connections MUST be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Unplug the power wiring connector from the operator to avoid interference with the operator. Connect the green wire to the earth ... 7. The location of the power disconnect should be visible and clearly labeled. • ALL power and control wiring MUST be on the operator. 3. SOLAR APPLICATIONS: For solar applications refer to the junction box on a dedicated circuit and well protected. Run the AC power wires to...
... on a separate fused line of adequate capacity. • ALL electrical connections MUST be wired for either 120 Vac or 240 Vac or a solar panel (not provided). Unplug the power wiring connector from the operator to avoid interference with the operator. Connect the green wire to the earth ... 7. The location of the power disconnect should be visible and clearly labeled. • ALL power and control wiring MUST be on the operator. 3. SOLAR APPLICATIONS: For solar applications refer to the junction box on a dedicated circuit and well protected. Run the AC power wires to...
CSL24VDC Installation Manual
Page 18
... other end of the red (+) wire from new wire harness kit + - + - 33AH Batteries 16 CONNECT BATTERIES 33AH BATTERIES The batteries are for battery backup or solar installation.
... other end of the red (+) wire from new wire harness kit + - + - 33AH Batteries 16 CONNECT BATTERIES 33AH BATTERIES The batteries are for battery backup or solar installation.
CSL24VDC Installation Manual
Page 32
...'s (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and 3 LED blinks once. Com AUX Relay 2 N.O. Energizes at close limit. ON ON OFF Energizes when AC power or solar power is between 1,000 and 9,999,000 cycles. For an additional audible or visual display, connect an off . connect an external buzzer or light (low...
...'s (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and 3 LED blinks once. Com AUX Relay 2 N.O. Energizes at close limit. ON ON OFF Energizes when AC power or solar power is between 1,000 and 9,999,000 cycles. For an additional audible or visual display, connect an off . connect an external buzzer or light (low...
CSL24VDC Installation Manual
Page 34
... slack, wear or damage Inspect for wear or damage Check all for proper operation Inspect all power (AC, solar, battery) to gate hardware. • ALL maintenance MUST be performed by a LiftMaster professional. • Activate gate ONLY when it can increase the risk of travel . • To reduce ...Failure to adjust and retest the gate operator properly can be seen clearly, is within ten percent of the two chain eye only LiftMaster part 29-NP712 for every comes with 33AH 10 feet of the 7AH batteries. 32 DESCRIPTION Entrapment Protection Devices TASK Check and test ...
... slack, wear or damage Inspect for wear or damage Check all for proper operation Inspect all power (AC, solar, battery) to gate hardware. • ALL maintenance MUST be performed by a LiftMaster professional. • Activate gate ONLY when it can increase the risk of travel . • To reduce ...Failure to adjust and retest the gate operator properly can be seen clearly, is within ten percent of the two chain eye only LiftMaster part 29-NP712 for every comes with 33AH 10 feet of the 7AH batteries. 32 DESCRIPTION Entrapment Protection Devices TASK Check and test ...
CSL24VDC Installation Manual
Page 35
... CODE NUMBER The second number shown after two minutes of each error code. For continued protection against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. Refer to the chart on the error code display. Press the CLOSE button to cycle to the oldest...
... CODE NUMBER The second number shown after two minutes of each error code. For continued protection against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. Refer to the chart on the error code display. Press the CLOSE button to cycle to the oldest...
CSL24VDC Installation Manual
Page 38
TROUBLESHOOTING CONTROL BOARD LEDS STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT OFF CHARGING ON Not charging Three stage battery charging TIMER OFF ON The timer is disabled The timer is enabled MEDIUM BLINK (1 ...
TROUBLESHOOTING CONTROL BOARD LEDS STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT OFF CHARGING ON Not charging Three stage battery charging TIMER OFF ON The timer is disabled The timer is enabled MEDIUM BLINK (1 ...
CSL24VDC Installation Manual
Page 39
...gate moves easily limit to limit. a) Open control active b) Vehicle loop detector active c) Loss of operator. Charge batteries by AC or solar power or replace batteries d) Defective control board d) Replace defective control board Control board powers up, but cannot set to CLOSE a) Check ... not "stuck on . b) Gate must be 23.0 Vdc or higher. a) Gate does not move to limit. Charge batteries by AC or solar power or replace batteries e) Entrapment Protection Device active e) Check all Entrapment Protection Device inputs for a "stuck on" sensor f) Vehicle loop detector or...
...gate moves easily limit to limit. a) Open control active b) Vehicle loop detector active c) Loss of operator. Charge batteries by AC or solar power or replace batteries d) Defective control board d) Replace defective control board Control board powers up, but cannot set to CLOSE a) Check ... not "stuck on . b) Gate must be 23.0 Vdc or higher. a) Gate does not move to limit. Charge batteries by AC or solar power or replace batteries e) Entrapment Protection Device active e) Check all Entrapment Protection Device inputs for a "stuck on" sensor f) Vehicle loop detector or...