Hardware Maintenance Manual for ThinkCentre A70z
Page 39
...use the Diagnostics feature of the Lenovo ThinkVantage Toolbox program to view symptoms and solutions for computer problems, access the Lenovo troubleshooting center, update system drivers, and review system information. Lenovo ThinkVantage Toolbox Note: The Lenovo ThinkVantage Toolbox program is only ...bootable diagnostic media, update system drivers, and review system information. Follow the instructions on page 34 for DOS diagnostic program from Lenovo. For more information about the Lenovo ThinkVantage Toolbox program, see "Lenovo Solution Center" on the screen. If you ...
...use the Diagnostics feature of the Lenovo ThinkVantage Toolbox program to view symptoms and solutions for computer problems, access the Lenovo troubleshooting center, update system drivers, and review system information. Lenovo ThinkVantage Toolbox Note: The Lenovo ThinkVantage Toolbox program is only ...bootable diagnostic media, update system drivers, and review system information. Follow the instructions on page 34 for DOS diagnostic program from Lenovo. For more information about the Lenovo ThinkVantage Toolbox program, see "Lenovo Solution Center" on the screen. If you ...
Hardware Maintenance Manual for ThinkCentre A70z
Page 48
... 2. See "Flash update procedures" on page 179 2. Run memory test 4. System board 1. Flash the system. System board 1. Press F3 to reset the log file 42 ThinkCentre Hardware Maintenance Manual Flash the system. System board 1. System board 1. Reboot the system 2. See "Flash update procedures" on page 179 2. System board Information only Re...
... 2. See "Flash update procedures" on page 179 2. Run memory test 4. System board 1. Flash the system. System board 1. Press F3 to reset the log file 42 ThinkCentre Hardware Maintenance Manual Flash the system. System board 1. System board 1. Reboot the system 2. See "Flash update procedures" on page 179 2. System board Information only Re...
Hardware Maintenance Manual for ThinkCentre A70z
Page 50
... system. Re-start the test, if necessary 1. See Chapter 6 "Diagnostics, Test and Recovery Information" on system and re-test 2. System board 1. System board 44 ThinkCentre Hardware Maintenance Manual System board 1. Power-off /on page 37 2. Press F3 to reset the log file 1. Go to "Undetermined problems" on page 179 2. Flash... System IRQ3 failure 001-271-XXX System IRQ4 failure FRU/Action System board 1. System board 1. System board Information only Re-start the test to review the log file 2. See "Flash update procedures" on IRQ3 2. Replace component under test 1.
... system. Re-start the test, if necessary 1. See Chapter 6 "Diagnostics, Test and Recovery Information" on system and re-test 2. System board 1. System board 44 ThinkCentre Hardware Maintenance Manual System board 1. Power-off /on page 37 2. Press F3 to reset the log file 1. Go to "Undetermined problems" on page 179 2. Flash... System IRQ3 failure 001-271-XXX System IRQ4 failure FRU/Action System board 1. System board 1. System board Information only Re-start the test to review the log file 2. See "Flash update procedures" on IRQ3 2. Replace component under test 1.
Hardware Maintenance Manual for ThinkCentre A70z
Page 52
... Video test halt, error threshold exceeded 005-197-XXX Video test warning 005-198-XXX Video test aborted FRU/Action 1. System board 1. Press F3 to review the log file 2. If a component is called out in warning statement 4. System board 1. Re-run test 3. System board 1. See "Flash update procedures" on page 37...
... Video test halt, error threshold exceeded 005-197-XXX Video test warning 005-198-XXX Video test aborted FRU/Action 1. System board 1. Press F3 to review the log file 2. If a component is called out in warning statement 4. System board 1. Re-run test 3. System board 1. See "Flash update procedures" on page 37...
Hardware Maintenance Manual for ThinkCentre A70z
Page 53
... a component is called out, make sure it is called out, make sure it is connected and/or enabled 2. Diskette drive 3. System board Chapter 7. Symptom-to review the log file 2. Flash the system and re-test. Flash the system and re-test 3. Replace component under test 1. Re-start the test, if necessary...
... a component is called out, make sure it is called out, make sure it is connected and/or enabled 2. Diskette drive 3. System board Chapter 7. Symptom-to review the log file 2. Flash the system and re-test. Flash the system and re-test 3. Replace component under test 1. Re-start the test, if necessary...
Hardware Maintenance Manual for ThinkCentre A70z
Page 54
...Go to reset the log file 1. Run setup, enable port 3. System board System board Information only Re-start the test, if necessary 48 ThinkCentre Hardware Maintenance Manual Press F3 to "Undetermined problems" on page 63 2. Make sure the component that is called out in warning statement 4. Replace..., Test and Recovery Information" on page 179 3. Replace the component that is called out, make sure it is connected and/or enabled. Go to review the log file 2. System board 1. Flash the system and re-test. See "Flash update procedures" on page 179 3. Flash the system. If ...
...Go to reset the log file 1. Run setup, enable port 3. System board System board Information only Re-start the test, if necessary 48 ThinkCentre Hardware Maintenance Manual Press F3 to "Undetermined problems" on page 63 2. Make sure the component that is called out in warning statement 4. Replace..., Test and Recovery Information" on page 179 3. Replace the component that is called out, make sure it is connected and/or enabled. Go to review the log file 2. System board 1. Flash the system and re-test. See "Flash update procedures" on page 179 3. Flash the system. If ...
Hardware Maintenance Manual for ThinkCentre A70z
Page 55
... out, make sure it is connected and/or enabled. Replace component under test 1. System board 1. System board 1. Reboot the system 2. Run memory test 4. Go to review the log file 2. System board 1. Flash the system and re-test. See "Flash update procedures" on page 179 2. Remove USB device(s) and re-test 2. Press...
... out, make sure it is connected and/or enabled. Replace component under test 1. System board 1. System board 1. Reboot the system 2. Run memory test 4. Go to review the log file 2. System board 1. Flash the system and re-test. See "Flash update procedures" on page 179 2. Remove USB device(s) and re-test 2. Press...
Hardware Maintenance Manual for ThinkCentre A70z
Page 56
...out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 37 2. Press F3 to review the log file 2. Re-run test 3. Press F3 to review the log file 2. Re-start the test to reset the log file 018-197-XXX PCI Card test warning 1. Make ... 1. Replace the component that is called out, make sure it is connected and/or enabled. Go to "Undetermined problems" on page 63 50 ThinkCentre Hardware Maintenance Manual Replace component under test 015-198-XXX USB port test aborted 1. System board 018-195-XXX PCI Card Test aborted by user...
...out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 37 2. Press F3 to review the log file 2. Re-run test 3. Press F3 to review the log file 2. Re-start the test to reset the log file 018-197-XXX PCI Card test warning 1. Make ... 1. Replace the component that is called out, make sure it is connected and/or enabled. Go to "Undetermined problems" on page 63 50 ThinkCentre Hardware Maintenance Manual Replace component under test 015-198-XXX USB port test aborted 1. System board 018-195-XXX PCI Card Test aborted by user...
Hardware Maintenance Manual for ThinkCentre A70z
Page 57
... 1. System board Information only Re-start the test to -FRU Index 51 Re-run test 3. If a component is called out in warning statement 4. Go to review the log file 2. Flash the system and re-test. System board Chapter 7. Go to "Undetermined problems" on page 63 1. PCI card 2. See "Flash update procedures...
... 1. System board Information only Re-start the test to -FRU Index 51 Re-run test 3. If a component is called out in warning statement 4. Go to review the log file 2. Flash the system and re-test. System board Chapter 7. Go to "Undetermined problems" on page 63 1. PCI card 2. See "Flash update procedures...
Hardware Maintenance Manual for ThinkCentre A70z
Page 58
...to "Undetermined problems" on page 179 3. Press F3 to "Undetermined problems" on page 179 3. Check power supply 3. System board 52 ThinkCentre Hardware Maintenance Manual Reseat IDE signal cable 4. IDE device 5. IDE signal cable 2. See "Flash update procedures" on page 179 3. ...reset the log file 1. SCSI adapter card, if installed 5. System board 1. See "Flash update procedures" on page 63 2. Go to review the log file 2. SCSI device 4. Replace the component under function test No action 1. Replace component under test 1. If a component is called...
...to "Undetermined problems" on page 179 3. Press F3 to "Undetermined problems" on page 179 3. Check power supply 3. System board 52 ThinkCentre Hardware Maintenance Manual Reseat IDE signal cable 4. IDE device 5. IDE signal cable 2. See "Flash update procedures" on page 179 3. ...reset the log file 1. SCSI adapter card, if installed 5. System board 1. See "Flash update procedures" on page 63 2. Go to review the log file 2. SCSI device 4. Replace the component under function test No action 1. Replace component under test 1. If a component is called...
Hardware Maintenance Manual for ThinkCentre A70z
Page 59
... test 3. Check power supply 3. Replace the component that is connected and/or enabled. Go to reset the log file 1. Re-start the test to review the log file 2. Re-start the test to "Undetermined problems" on page 63 2. See "Flash update procedures" on page 37 2. RAID signal cable... action 1. If a component is called out, make sure it is called out in warning statement 4. Flash the system and re-test. Go to review the log file 2. Flash the system and re-test. Replace component under test 1. RAID adapter card, if installed 4. System board Information only Re...
... test 3. Check power supply 3. Replace the component that is connected and/or enabled. Go to reset the log file 1. Re-start the test to review the log file 2. Re-start the test to "Undetermined problems" on page 63 2. See "Flash update procedures" on page 37 2. RAID signal cable... action 1. If a component is called out, make sure it is called out in warning statement 4. Flash the system and re-test. Go to review the log file 2. Flash the system and re-test. Replace component under test 1. RAID adapter card, if installed 4. System board Information only Re...
Hardware Maintenance Manual for ThinkCentre A70z
Page 60
Go to "Undetermined problems" on page 37 2. Replace component under function test 54 ThinkCentre Hardware Maintenance Manual System board 1. Audio card, if installed 3. Make sure the component that is connected and/or enabled. Flash the system and re-test. ... 179 3. Audio card, if installed 4. Run Setup 2. Flash the system and re-test. Flash the system. System board Information only Re-start the test to review the log file 2. Flash the system and re-test. Flash the system and re-test. Speakers 2. If a component is called out, make sure it is...
Go to "Undetermined problems" on page 37 2. Replace component under function test 54 ThinkCentre Hardware Maintenance Manual System board 1. Audio card, if installed 3. Make sure the component that is connected and/or enabled. Flash the system and re-test. ... 179 3. Audio card, if installed 4. Run Setup 2. Flash the system and re-test. Flash the system. System board Information only Re-start the test to review the log file 2. Flash the system and re-test. Flash the system and re-test. Speakers 2. If a component is called out, make sure it is...
Hardware Maintenance Manual for ThinkCentre A70z
Page 61
... it is called out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 179 3. Press F3 to review the log file 2. Press F3 to review the log file 2. Speakers 2. Audio card, if installed 3. Make sure the component that is connected and/or enabled. See "Flash update procedures...
... it is called out is connected and/or enabled. See Chapter 6 "Diagnostics, Test and Recovery Information" on page 179 3. Press F3 to review the log file 2. Press F3 to review the log file 2. Speakers 2. Audio card, if installed 3. Make sure the component that is connected and/or enabled. See "Flash update procedures...
Hardware Maintenance Manual for ThinkCentre A70z
Page 62
... and/or enabled. Press F3 to "Undetermined problems" on page 63 1. See "Flash update procedures" on page 37 2. Go to review the log file 2. System board Information only Re-start the test, if necessary 1. Re-run test 3. Flash the system. See Chapter... Recovery Information" on page 179 3. Re-run test 3. Microprocessor(s) 2. System board Information only Re-start the test, if necessary 56 ThinkCentre Hardware Maintenance Manual Replace the component that is connected and/or enabled. Go to reset the log file 1. See "Flash update procedures" ...
... and/or enabled. Press F3 to "Undetermined problems" on page 63 1. See "Flash update procedures" on page 37 2. Go to review the log file 2. System board Information only Re-start the test, if necessary 1. Re-run test 3. Flash the system. See Chapter... Recovery Information" on page 179 3. Re-run test 3. Microprocessor(s) 2. System board Information only Re-start the test, if necessary 56 ThinkCentre Hardware Maintenance Manual Replace the component that is connected and/or enabled. Go to reset the log file 1. See "Flash update procedures" ...
Hardware Maintenance Manual for ThinkCentre A70z
Page 63
..." on page 37 2. Replace the component under function test 1. See "Flash update procedures" on page 63 2. System board No action 1. Re-start the test to review the log file 2. Replace the component under test 1. See "Undetermined problems" on page 179 3. Go to "Undetermined problems" on page 63 1. See Chapter 6 "Diagnostics, Test... Sensor(s) test halt, error threshold exceeded 175-197-XXX Thermal Sensor(s) test warning 175-198-XXX Thermal Sensor(s) test aborted FRU/Action 1. Press F3 to review the log file 2.
..." on page 37 2. Replace the component under function test 1. See "Flash update procedures" on page 63 2. System board No action 1. Re-start the test to review the log file 2. Replace the component under test 1. See "Undetermined problems" on page 179 3. Go to "Undetermined problems" on page 63 1. See Chapter 6 "Diagnostics, Test... Sensor(s) test halt, error threshold exceeded 175-197-XXX Thermal Sensor(s) test warning 175-198-XXX Thermal Sensor(s) test aborted FRU/Action 1. Press F3 to review the log file 2.