SISTP1040-551-LRT Install Guide Rev B - Page 2
... domestic and international sales offices, go to www.lantronix.com/about/contact. Lantronix
SISTP1040-551-LRT Install Guide
Intellectual Property
© 2022 Lantronix, Inc. Contacts
Lantronix Corporate Headquarters 7535 Irvine Center Drive Suite100 Irvine, CA 92618, USA Toll Free: 800-526-8766 Phone: 949-453-3990 Fax: 949-453-3995
Technical Support Phone: +1.952.358.3601 or 1.800.260.1312...
SISTP1040-551-LRT Install Guide Rev B - Page 3
Lantronix
SISTP1040-551-LRT Install Guide
Table of Contents
1 Introduction ...4 Product Description ...4 Ordering Information...4 About This Manual...4 Related Manuals...4 Features ...4 PoE Features ...5 Specifications ...5 Application Example ...6
2 Installation ...7 Package Checklist ...7 Cautions and Warnings ...7 Safety Instructions ...7 Dimensions ...8 Front, Top, and Back Panels ...9 DIN-...
SISTP1040-551-LRT Install Guide Rev B - Page 4
... settings • Check switch status by reading LED status • Troubleshoot switch installation
Related Manuals
• SISTP1040-551-LRT Quick Start Guide, 33840 • PS-DC-DUAL-5624T Power Supply Install Guide, 33788
Features
• IEEE 802.3af/at/bt PoE and PoH PSE support • Redundant Power Input terminals; Industrial power supply sold separately. SFP Modules
Lantronix...
SISTP1040-551-LRT Install Guide Rev B - Page 5
... table
Power Status LED: Indication of 26 Lantronix
SISTP1040-551-LRT Install Guide
• 2k MAC forwarding addresses • Industrial design: fanless, wide operating temperature range (-40 to +75°C), Dual power input (48~57
VDC), IP30 • DIP switch to enable/disable Power alarm, Broadcast storm limit, Jumbo Frame support, PoH mode /
802.3bt mode, and...
SISTP1040-551-LRT Install Guide Rev B - Page 7
... save the packaging for Wall mount brackets and DIN Clip) One DC power Terminal Block One printed Quick Start Guide One documentation postcard
Contact your sales representative if any item is missing. Lantronix
SISTP1040-551-LRT Install Guide
2 Installation
Package Checklist
Verify that a Power Supply is not included with the switch (sold separately).
The equipment power supply cord...
SISTP1040-551-LRT Install Guide Rev B - Page 12
...that might be emitting laser energy. The Fiber Optic Association, Inc.is a transmit (TX) and receive (RX) signal. Lantronix
SISTP1040-551-LRT Install Guide
Ethernet Interface Connection (Fiber, SFP)
100/1000 Mbps fiber port: Insert an MSA compliant 100 Mbps or 1000 Mbps small ... to promote professionalism in the SFP slot. Note: see the related SFP device manual for additional information.
SISTP1040-551-LRT Install Guide Rev B - Page 13
... you enable or disable the rate limiting of 1519~9216 bytes.
33841 Rev. Lantronix
SISTP1040-551-LRT Install Guide
DIP Switch Settings
The top panel 5-position DIP switch is labeled SW and is 10 Mbps line rate.
3.
Disable Broadcast Storm rate limit. Disable Jumbo frame support. Enable PoE Power Cutoff when no SFP link. The feature becomes active...
SISTP1040-551-LRT Install Guide Rev B - Page 14
...;
On: Enable PoE Power Cutoff function when no SFP link. Lantronix
SISTP1040-551-LRT Install Guide
4.
PoE PoH / PoE 802.3bt Mode
PoH (Power over
...In PoH mode the switch becomes compatible with PDs supporting PoH mode (pre-bt standard).
802.3bt Mode...100 m
Power over HDBaseT): HDBaseT is no SFP link. 1.
Set the DIP switch to the switch; the feature will pass through...
SISTP1040-551-LRT Install Guide Rev B - Page 15
... setting the DIP switch of the DC terminal block connector as shown right and below. The alarm relay output contacts have a current carrying capacity of 26 B
https://www.lantronix.com...alarm relay is "Normal Open" and it will detect any power failure is detected. Lantronix
SISTP1040-551-LRT Install Guide
Alarm Relay Connection
The alarm relay output contacts (ALM) are located in the middle...
SISTP1040-551-LRT Install Guide Rev B - Page 17
... Ohms / 500VDC / 25 deg. Lantronix
SISTP1040-551-LRT Install Guide
3 Power Supply Information
Lantronix offers two compatible power supply options: PS... Full load burn in test • RoHS compliant
25160 Specifications
Output: • Output Voltage 48VDC (adjustable) •...www.lantronix.com/
Page 17 of 26 Storage: -40°C to +70°C. Load Regulation ±1.0% • Setup, ...
SISTP1040-551-LRT Install Guide Rev B - Page 21
Lantronix
SISTP1040-551-LRT Install Guide
Troubleshooting Procedure
If the switch fails, isolate and correct the fault by determining the answers to the following : □ Is the power source live and to spec? If one of this manual for loose power connections, power losses or surges at the power outlet. See the related section of the Green Power LEDs...
SISTP1040-551-LRT Install Guide Rev B - Page 22
... and found to comply with the instruction manual, may cause harmful interference to Part 15 of 26 B
https://www.lantronix.com/
Page 22 of the FCC rules. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in a commercial environment. Lantronix
SISTP1040-551-LRT Install Guide
Regulatory Agency Information
Vibration, shock & freefall...
SISTP1040-551-LRT Install Guide Rev B - Page 24
...information that can help the Tech Support Specialist. Lantronix
SISTP1040-551-LRT Install Guide
Declaration of Conformity
Declaration of Conformity
Manufacture's Name: Lantronix, Inc. Manufacture's Address: 7535 Irvine Center Drive, Suite100, Irvine, CA 92618, USA
Declares that the equipment specified above conforms to the following Product Regulations: FCC Part 15 Subpart B Class A, EN 55032...
SISTP1040-551-LRT Install Guide Rev B - Page 25
Lantronix
SISTP1040-551-LRT Install Guide
Record Device and System Information
After performing the troubleshooting procedures above, and before calling or emailing Tech Support, record as much information as possible to resolve the problem (e.g., changing DIP switch setting, etc The model # and serial # of 26 Record Model name SN LED Status Current Alarm data and alarm history Power ...
SISTP1040-551-LRT Quick Start Guide Rev A - Page 1
... operation in Environments A and B.
33840 Rev. Note: See the full Install Guide for mounting. 2.
DIN-Rail Mounting
1. Hook the unit over the DIN rail. 3. See the Install Guide. Connect the switch to provide dual power capability. Package Checklist
Verify that the box contains one SISTP1040-551-LRT switch, two Wall-mount brackets, one DIN-Rail Clip, four...