EDS-MD - Product Brief
Page 1
... highest level of safety. Virtual COM ports can work with a Gigabit (10/100/1000Mpbs) network interface. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with EDS-MD without any electronic or medical device. With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. If a grounding...
... highest level of safety. Virtual COM ports can work with a Gigabit (10/100/1000Mpbs) network interface. EDS-MD boasts 4, 8 or 16 individually isolated RS-232 serial ports with EDS-MD without any electronic or medical device. With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. If a grounding...
EDS-MD - Product Brief
Page 2
...2004 • CAN/CSA-C22.2; EDS-MD Features > Standards Ordering Information • IEEE 802.3 • IEEE 802.3u • IEEE 802.3ab • IEEE 802.3x • USB 2.0 > Hardware United States Call: 800.422.7055 Email: sales@lantronix.com Buy Online: http://www.lantronix.com Europe Call: +31 (0)... • EN 55022: 2006 + A1: 2007 • EN61000-3-2: 2006 + A1: 2009 + A2: 2009 • EN61000-3-3: 2008 © 2011, Lantronix, Inc. No. 601.1: 1990; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of...
...2004 • CAN/CSA-C22.2; EDS-MD Features > Standards Ordering Information • IEEE 802.3 • IEEE 802.3u • IEEE 802.3ab • IEEE 802.3x • USB 2.0 > Hardware United States Call: 800.422.7055 Email: sales@lantronix.com Buy Online: http://www.lantronix.com Europe Call: +31 (0)... • EN 55022: 2006 + A1: 2007 • EN61000-3-2: 2006 + A1: 2009 + A2: 2009 • EN61000-3-3: 2008 © 2011, Lantronix, Inc. No. 601.1: 1990; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of...
EDS-MD - Product Brief (A4 Format)
Page 1
...a serial interface to and from remote device servers over the Internet with the highest level of EDS-MD or other connected devices will not be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to the ...for higher performance Set up and configuration of EDS-MD is simple with industrystandard management tools including Web, CLI and XML. With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. EDS-MD Highlights: > UL and IEC-60601 compliance ...
...a serial interface to and from remote device servers over the Internet with the highest level of EDS-MD or other connected devices will not be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to the ...for higher performance Set up and configuration of EDS-MD is simple with industrystandard management tools including Web, CLI and XML. With Lantronix' proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can be affected. EDS-MD Highlights: > UL and IEC-60601 compliance ...
EDS-MD - Product Brief (A4 Format)
Page 2
... T 0601-1:1999, Japan Safety Standard for Information Technology Equipment • CAN/CSA C22.2; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. All rights reserved. 940-020-R Rev B 11/11 EDS-MD Features Ordering Information > Standards • IEEE 802.3 • IEEE 802.3u • IEEE...
... T 0601-1:1999, Japan Safety Standard for Information Technology Equipment • CAN/CSA C22.2; and Lantronix are registered trademarks, and EDS-MD, Secure Com Port Redirector and DeviceInstaller are the property of Lantronix, Inc. All rights reserved. 940-020-R Rev B 11/11 EDS-MD Features Ordering Information > Standards • IEEE 802.3 • IEEE 802.3u • IEEE...
EDS-MD - User Guide
Page 2
... policy, please go to our web site at www.lantronix.com/about/contact. A B C D Comments Initial Document for any means without notice. Windows is a trademark of XEROX Corporation. EDS-MD User Guide 2 Contacts Lantronix Corporate Headquarters 167 Technology Drive Irvine, CA 92618, USA... Phone: 949-453-3990 Fax: 949-450-7249 Technical Support Online: www.lantronix.com/support Sales Offices For a current list of Lantronix. Disclaimer The information ...
... policy, please go to our web site at www.lantronix.com/about/contact. A B C D Comments Initial Document for any means without notice. Windows is a trademark of XEROX Corporation. EDS-MD User Guide 2 Contacts Lantronix Corporate Headquarters 167 Technology Drive Irvine, CA 92618, USA... Phone: 949-453-3990 Fax: 949-450-7249 Technical Support Online: www.lantronix.com/support Sales Offices For a current list of Lantronix. Disclaimer The information ...
EDS-MD - User Guide
Page 11
...IP (VIP) Counters 83 To View VIP Counters 83 Using Web Manager 83 Using the CLI 83 Using XML 83 15: Branding the EDS-MD4/8/16 84 Web Manager Customization 84 Short and Long Name Customization 85 To Customize Short or Long Names 85 Using Web Manager 85 ... Support 86 Appendix B: Binary to Hexadecimal Conversions 87 Converting Binary to Hexadecimal 87 Conversion Table 87 Scientific Calculator 87 Appendix C: Compliance 89 Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts 93 Cables and Adapters 93 Adapters and Serial Port Pinouts 94 EDS-MD User Guide 11
...IP (VIP) Counters 83 To View VIP Counters 83 Using Web Manager 83 Using the CLI 83 Using XML 83 15: Branding the EDS-MD4/8/16 84 Web Manager Customization 84 Short and Long Name Customization 85 To Customize Short or Long Names 85 Using Web Manager 85 ... Support 86 Appendix B: Binary to Hexadecimal Conversions 87 Converting Binary to Hexadecimal 87 Conversion Table 87 Scientific Calculator 87 Appendix C: Compliance 89 Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts 93 Cables and Adapters 93 Adapters and Serial Port Pinouts 94 EDS-MD User Guide 11
EDS-MD - User Guide
Page 14
... 17-1 Binary to Hexadecimal Conversion 87 Table 18-1 Applicable Medical Standards 89 Table 18-2 Applicable ITE Standards 89 Table 18-3 Regulatory Compliance 90 Table 19-1 Lantronix Cables and Adapters 93 EDS-MD User Guide 14
... 17-1 Binary to Hexadecimal Conversion 87 Table 18-1 Applicable Medical Standards 89 Table 18-2 Applicable ITE Standards 89 Table 18-3 Regulatory Compliance 90 Table 19-1 Lantronix Cables and Adapters 93 EDS-MD User Guide 14
EDS-MD - User Guide
Page 15
...Lantronix Cables, Adapters and Serial Port Pinouts Description Main features of the three models. Instructions on configuring settings. It is intended for configuring email, CLI and XML settings. Summary of Chapters The remaining chapters in this product into their designs. Instructions for installing the EDS-MD. Note: EDS-MD device servers (which include models EDS-MD4, EDS...-MD8 and EDSMD16) are installing this guide include: Chapter 2: Introduction 3: Installation of EDS-MD4/8/16 ...
...Lantronix Cables, Adapters and Serial Port Pinouts Description Main features of the three models. Instructions on configuring settings. It is intended for configuring email, CLI and XML settings. Summary of Chapters The remaining chapters in this product into their designs. Instructions for installing the EDS-MD. Note: EDS-MD device servers (which include models EDS-MD4, EDS...-MD8 and EDSMD16) are installing this guide include: Chapter 2: Introduction 3: Installation of EDS-MD4/8/16 ...
EDS-MD - User Guide
Page 16
...to supply connections when connecting to power strips, rather than the voltage and current rating marked on the internal power supply serviceable only by Lantronix. Power Plug When disconnecting the power cable from the socket, pull on the plug, not the cord. Always ... that could affect over current protection and supply wiring. Grounding Maintain reliable grounding of the EDS-MD. Warning: This equipment is broken. EDS-MD User Guide 16 Do not operate the EDS-MD if the housing is not suitable for medical application. Install the unit near an AC ...
...to supply connections when connecting to power strips, rather than the voltage and current rating marked on the internal power supply serviceable only by Lantronix. Power Plug When disconnecting the power cable from the socket, pull on the plug, not the cord. Always ... that could affect over current protection and supply wiring. Grounding Maintain reliable grounding of the EDS-MD. Warning: This equipment is broken. EDS-MD User Guide 16 Do not operate the EDS-MD if the housing is not suitable for medical application. Install the unit near an AC ...
EDS-MD - User Guide
Page 17
...safe operation of wall-mounted equipment. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Before operating the EDS-MD, make sure the EDS-MD mounting is not compromised. Maintain reliable earthing of the equipment is secured. use a USB port as a cellular phone, PDA ...Base-T/100 Base-TX/ 1000 Base-T. Only connect device ports to equipment with the maximum ambient temperature (Tma) specified by Lantronix. METTRE AU REBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT.
...safe operation of wall-mounted equipment. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Before operating the EDS-MD, make sure the EDS-MD mounting is not compromised. Maintain reliable earthing of the equipment is secured. use a USB port as a cellular phone, PDA ...Base-T/100 Base-TX/ 1000 Base-T. Only connect device ports to equipment with the maximum ambient temperature (Tma) specified by Lantronix. METTRE AU REBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT.
EDS-MD - User Guide
Page 19
... the latest documentation and the following additional documentation. DeviceInstaller Online Help Instructions for using the Lantronix Windows-based utility to locate the EDS-MD and to create and Online Help virtual com ports. Com Port Redirector Quick Start Instructions for using...its current settings. Secure Com Port Redirector User Guide Instructions for getting the EDS-MD up and running. 1: Using This Guide Additional Documentation Visit the Lantronix Web site at www.lantronix.com/support/documentation for XML configuration and status. Instructions for using a Telnet ...
... the latest documentation and the following additional documentation. DeviceInstaller Online Help Instructions for using the Lantronix Windows-based utility to locate the EDS-MD and to create and Online Help virtual com ports. Com Port Redirector Quick Start Instructions for using...its current settings. Secure Com Port Redirector User Guide Instructions for getting the EDS-MD up and running. 1: Using This Guide Additional Documentation Visit the Lantronix Web site at www.lantronix.com/support/documentation for XML configuration and status. Instructions for using a Telnet ...
EDS-MD - User Guide
Page 21
...or MAC address. This address references the specific unit. XML is easily editable with a standard text or XML editor. (See the EDS-MD Command Reference Guide for instructions and commands.) Addresses and Port Numbers Hardware Address The hardware address is also referred to an IP network... traceroute operations. Conduct forward or reverse DNS lookup operations. View all settings easily through a web browser using the Lantronix Web Manager. (See "Configuration Using Web Manager" on page 30.) DeviceInstaller: Configure the IP address and related settings and view current settings ...
...or MAC address. This address references the specific unit. XML is easily editable with a standard text or XML editor. (See the EDS-MD Command Reference Guide for instructions and commands.) Addresses and Port Numbers Hardware Address The hardware address is also referred to an IP network... traceroute operations. Conduct forward or reverse DNS lookup operations. View all settings easily through a web browser using the Lantronix Web Manager. (See "Configuration Using Web Manager" on page 30.) DeviceInstaller: Configure the IP address and related settings and view current settings ...
EDS-MD - User Guide
Page 22
...UDP port and corresponding tunnel will be available, depending on the label is also the product serial number. Figure 2-1 EDS-MD Product Label Bar Code Serial Number Part Number SN: XXXXXXXXXXXXX PN: XXXXXXXXXXXXX Made In: XXXXXXX Rev: XXX YYWWW Revision Manufacturing Date Code...(Command Mode configuration) TCP Port 80: HTTP (Web Manager configuration) TCP Port 21: FTP UDP Port 30718: LDP (Lantronix Discovery Protocol) port TCP/UDP Port 10001: Tunnel 1 Note: Additional TCP/UDP ports and tunnels will increase sequentially (i.e., TCP/UDP Port 1000X:...
...UDP port and corresponding tunnel will be available, depending on the label is also the product serial number. Figure 2-1 EDS-MD Product Label Bar Code Serial Number Part Number SN: XXXXXXXXXXXXX PN: XXXXXXXXXXXXX Made In: XXXXXXX Rev: XXX YYWWW Revision Manufacturing Date Code...(Command Mode configuration) TCP Port 80: HTTP (Web Manager configuration) TCP Port 21: FTP UDP Port 30718: LDP (Lantronix Discovery Protocol) port TCP/UDP Port 10001: Tunnel 1 Note: Additional TCP/UDP ports and tunnels will increase sequentially (i.e., TCP/UDP Port 1000X:...
EDS-MD - User Guide
Page 23
...: RS-232 serial devices that require network connectivity. EDS-MD User Guide 23 Category 5 cabling with the EDS-MD, see the Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on page 93). An available connection to your EDS-MD package, or an RJ45 patch cable and DTE adapter. For... a list of the Lantronix cables and adapters you need the following items: One EDS-MD device server (an EDS-MD4, EDS-MD8 or EDS-MD16) One RJ45 CAT 5E cable ...
...: RS-232 serial devices that require network connectivity. EDS-MD User Guide 23 Category 5 cabling with the EDS-MD, see the Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on page 93). An available connection to your EDS-MD package, or an RJ45 patch cable and DTE adapter. For... a list of the Lantronix cables and adapters you need the following items: One EDS-MD device server (an EDS-MD4, EDS-MD8 or EDS-MD16) One RJ45 CAT 5E cable ...
EDS-MD - User Guide
Page 27
... Humidity 0% to 95% non-condensing Atmospheric Pressure 50 kPa to 105 kPa 20% to one or more serial devices All EDS-MD serial ports support RS-232 devices. 1. See Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on the wall. If using AC power, do not use . 3. ...Insert the power cord into an AC wall outlet. 5. Power up the serial devices. Power off the serial devices. 2. Attach a CAT 5 serial cable between the EDS-MD Ethernet port and...
... Humidity 0% to 95% non-condensing Atmospheric Pressure 50 kPa to 105 kPa 20% to one or more serial devices All EDS-MD serial ports support RS-232 devices. 1. See Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts (on the wall. If using AC power, do not use . 3. ...Insert the power cord into an AC wall outlet. 5. Power up the serial devices. Power off the serial devices. 2. Attach a CAT 5 serial cable between the EDS-MD Ethernet port and...
EDS-MD - User Guide
Page 28
...search. This is a free utility program provided by Lantronix that discovers, configures, upgrades and manages Lantronix Device Servers. These addresses are Display Only in the range of 169.254.0.1 to 169.254.255.254, with the EDS-MD module's current IP address, if the IP address was... obtained dynamically. Click Start -> All Programs -> Lantronix -> DeviceInstaller -> DeviceInstaller. 3. the full configuration may be accessed via Web Manager, CLI or XML. EDS-MD User Guide 28 To perform another search, ...
...search. This is a free utility program provided by Lantronix that discovers, configures, upgrades and manages Lantronix Device Servers. These addresses are Display Only in the range of 169.254.0.1 to 169.254.255.254, with the EDS-MD module's current IP address, if the IP address was... obtained dynamically. Click Start -> All Programs -> Lantronix -> DeviceInstaller -> DeviceInstaller. 3. the full configuration may be accessed via Web Manager, CLI or XML. EDS-MD User Guide 28 To perform another search, ...
EDS-MD - User Guide
Page 30
...: You can also access the Web Manager by DHCP. 3. Lantronix supports the latest version of the web page would force re-authentication to configure the EDS-MD4, EDS-MD8 and EDS-MD16 using DeviceInstaller (see the EDS-MD Quick Start Guide) or automatically by selecting the Web Configuration tab... place the next time the web page is accessed. The IP address may have been assigned manually using Web Manager, the Lantronix browser-based configuration tool. EDS-MD User Guide 30 Logging out of Internet Explorer, Mozilla Suite, Mozilla Firefox, Safari, Chrome or Opera. 2. The unit's ...
...: You can also access the Web Manager by DHCP. 3. Lantronix supports the latest version of the web page would force re-authentication to configure the EDS-MD4, EDS-MD8 and EDS-MD16 using DeviceInstaller (see the EDS-MD Quick Start Guide) or automatically by selecting the Web Configuration tab... place the next time the web page is accessed. The IP address may have been assigned manually using Web Manager, the Lantronix browser-based configuration tool. EDS-MD User Guide 30 Logging out of Internet Explorer, Mozilla Suite, Mozilla Firefox, Safari, Chrome or Opera. 2. The unit's ...
EDS-MD - User Guide
Page 33
... the left side of every web page. Shows statistics and lets you upload an existing certificate or create a new self-signed certificate. 61 EDS-MD User Guide 33 Lets you change the current configuration for SSH server host keys, SSH 58 server authorized users, SSH client known hosts, and... Query Port Lets you change the current configuration and Command 35 mode settings of 5 seconds after rebooting the unit before attempting to the Lantronix home page. In Chrome or Safari, it is available at the very bottom of the page. Lets you perform various diagnostic procedures. 70...
... the left side of every web page. Shows statistics and lets you upload an existing certificate or create a new self-signed certificate. 61 EDS-MD User Guide 33 Lets you change the current configuration for SSH server host keys, SSH 58 server authorized users, SSH client known hosts, and... Query Port Lets you change the current configuration and Command 35 mode settings of 5 seconds after rebooting the unit before attempting to the Lantronix home page. In Chrome or Safari, it is available at the very bottom of the page. Lets you perform various diagnostic procedures. 70...
EDS-MD - User Guide
Page 81
... from the Lantronix Web site (www.lantronix.com/support/downloads/) or by sending the file to the EDS-MD4/8/16 over an FTP connection. ftp> put edsmd_7_2_0_0R8.rom firmware.rom 200 PORT command successful. Example FTP session: $ ftp 192.168.10.127 Connected to transfer files. EDS-MD User Guide... 81 Remote system type is UNIX. The destination file name on the EDS-MD4, EDS-MD8 or EDS-MD16 must be updated by using PASV. 150 Ok to send data. 226 File receive...
... from the Lantronix Web site (www.lantronix.com/support/downloads/) or by sending the file to the EDS-MD4/8/16 over an FTP connection. ftp> put edsmd_7_2_0_0R8.rom firmware.rom 200 PORT command successful. Example FTP session: $ ftp 192.168.10.127 Connected to transfer files. EDS-MD User Guide... 81 Remote system type is UNIX. The destination file name on the EDS-MD4, EDS-MD8 or EDS-MD16 must be updated by using PASV. 150 Ok to send data. 226 File receive...
EDS-MD - Command Reference
Page 31
... Values ip address in format nnn.nnn.nnn.nnn mac address in format xx:xx:xx:xx:xx:xx dynamic or static eth0 or wlan0 Lantronix EDS-MD 12 hex digits string in version format like 7.2.0.0R15 elapsed time in format d days hh:mm:ss saved or unsaved United States, Canada, France, ...Spain, Japan, or Other decimal number decimal number decimal number decimal number timestamp in format d days hh:mm:ss string EDS-MD Command Reference 31 Group Name arp clock device Table 4-8 XSR Group and Items Item Name arp entry Value Name ip address mac address time date...
... Values ip address in format nnn.nnn.nnn.nnn mac address in format xx:xx:xx:xx:xx:xx dynamic or static eth0 or wlan0 Lantronix EDS-MD 12 hex digits string in version format like 7.2.0.0R15 elapsed time in format d days hh:mm:ss saved or unsaved United States, Canada, France, ...Spain, Japan, or Other decimal number decimal number decimal number decimal number timestamp in format d days hh:mm:ss string EDS-MD Command Reference 31 Group Name arp clock device Table 4-8 XSR Group and Items Item Name arp entry Value Name ip address mac address time date...