Owner's Manual (English) - Page 1

... by explaining proper air conditioner maintenance and preventing improper use. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual. IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner.
Owner's Manual (English) - Page 2

...Conditioner/Heat Pump Owner's Manual TABLE OF CONTENTS Safety Precautions 3 Before Operation 7 Introduction 8 Electrical Safety 9 Installation 11 Control Locations 13 Maintenance and Service 21 FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can save you review our chart of troubleshooting tips. Just a little preventive care on your part can find them on...
Owner's Manual (English) - Page 7

...Manual 7 Consult a professional installer or electrician. 5. Due to direct airflow for installation. Contact an installation specialist for an extended period of oxygen deficiency, ventilate the room when used together with only an authorized replacement part...water can occur when handling sharp metal edges. 2. Service For repair and maintenance, contact your health. The fan rotates...
Owner's Manual (English) - Page 8

... Installation purpose and better appearance Aluminium or Architectural grille can be applied in PTAC and PTHP Units. Expanded Metal Grille Should be installed in this Manual This...Air Conditioner EXPANDED METAL GRILLE (For Superior Performance) LG PTAC and PTHP test condition is recommended with the National Electric Code. NOTICE This symbol indicates special notes. Introduction ...
Owner's Manual (English) - Page 9

...conditioner and contact a qualified service technician. Avoid shock hazard! Owner's Manual 9 Use Wall Receptacle Power...product in accordance with local electrical codes and regulations. Standard 265V grounding receptacle...the State of the unit voids all warranties and performance claims. This unit is ...Power cord may pose special problems. Consult a qualified electrician. Standard 265V grounding ...
Owner's Manual (English) - Page 15

...) CH 05 Mode Error CH 06 Set point Error CH 07 Bad Thermistor Wiring CH 09 Pressure Switch ErrorManual Controls ON OFF Fault Codes 1 2 3 4 5 6 7 LED Flash Rate Normal No power / failed board Indoor Air Thermistor Error Indoor Coil Thermistor Error Outdoor Air Thermistor Error (PTHP Only) Outdoor Coil Thermistor Error (PTHP Only) Mode Error Set point Error Bad Thermistor Wiring...
Owner's Manual (English) - Page 16

... out the bottom of control box. To replace the front grille, place the tabs over ...controls are in the OFF position. The authorized servicer has to check switches and ensure the switches...Cooling Only 16 Room Air Conditioner The standard settings will be in the desired position. This temperature... 3 PTAC/PTHP UNIT TYPE • TEMPERATURE LIMITING Temperature Limiting can save money by switches...
Owner's Manual (English) - Page 17

... are located behind the option cover of front grille and then lift up. The standard settings will be in the desired position. This temperature limiting is controlled by limiting the lowest ...176;F (22.2°C) Owner's Manual 17 To replace the front grille, place the tabs over the top of the unit and push the bottom of control box. The authorized service man has to check switches and...
Owner's Manual (English) - Page 18

See the installation Instruction in cool or heat modes. Wire # ...manual for heat pump and straight cool units with electric heat, respectively. Wiring Schematic for Straight Cool Unit. 24 Volt-N 24 Volt-L Compressor Heater Reversing Valve High Fan Low Fan GL GH O W Y R C (Molex Housing Spec 396-07V) 18 Room Air Conditioner When you install the digital/electronic thermostat, you must set...
Owner's Manual (English) - Page 19

... heat, respectively. When you install the digital / electronic thermostat, you must set at the Front Desk Control panel. Owner's Manual 19 This switch is OFF,...Spec 396-09V) Wiring Schematic for Remote Heat Pump • REMOTE WALL THERMOSTAT When the wires are not available. • ENERGY SAVER The energy saver switch #2 is on , it to the 24 Volt AC. See the installation Instruction...
Owner's Manual (English) - Page 22

... and Service Drainage ... plates, and the condenser itself should hydrocarbon based cleaners (e.g. Corrosion Resistant Models Corrosion resistant models subjected to clean the basepan, center partition and coils. Cabinet Front The...with a blanket or plastic bag to keep it could cause severe damage to the PTAC fins and coils. acetone, benzene, naphtha, gasoline, etc.) be sprayed with clean...
Owner's Manual (English) - Page 23

...runs intermittently. • Check voltage. Replace cord if circuit is high. Owner's Manual 23 This design feature helps remove moisture...replace fan motor. • Pay attention to any change , replace the motor. The water may not need to low speed. Repair or replace loose terminal. • Test capacitor. ENGLISH Maintenance and Service Common Problems and Solutions Troubleshooting...
Owner's Manual (English) - Page 25

..., causing the compressor to be cooled. • Check the set screw or clamp. If loose, repair or replace. • Check the system for a restriction. • If restricted, clean or replace. • Close if open . (If the compressor temperature is hitting air guide, rearrange the air handling parts. • Carefully rearrange tubing not to contact, compressor, shroud...
Owner's Manual (English) - Page 27

.... No other rights that fail due to territory. LG ELECTRONICS, INC. USA Should your home for delivery or pickup, install, instruct or replace house fuses, or connect house wiring or plumbing, or correction of air. 7. Service trips to replace the defective part. Damage caused by inadequate supply of unauthorized repairs. 2. Damage resulting from running the product in...
Owner's Manual (Español) - Page 27

...warranty, LGE will replace the defective part(s). Parts covered are warranted for the unexpired portion of the original warranty period. This warranty gives you, the original purchaser, specific legal rights and you may not apply to you will replace certain parts that vary from the date of original purchase, LGE will be responsible for delivery or pickup, install, instruct or replace...

LG LP090CED-Y8 Reviews

Do you have an experience with the LG LP090CED-Y8 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LG yet.

Popular LG LP090CED-Y8 Search Terms

The following terms are frequently used to search for LG LP090CED-Y8 support:

Ask a New Question
Use the box below to post a new question about LG LP090CED-Y8.
Manuals / Documents
Download any of our LG LP090CED-Y8 manuals for free!

We have the following 2 documents available for the LG LP090CED-Y8:
  • Owner's Manual (English)
  • Owner's Manual (Español)

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LG Manuals

Find free LG LP090CED-Y8 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LG Reviews

View thousands of LG LP090CED-Y8 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LG customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LG customer service rankings, employee comments and much more from our sister site.