ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual. IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use.
ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual. IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use.
Owner's Manual (English)
Page 2
... each unit. If you review our chart of Troubleshooting Tips first, you may not need it to call for warranty issues. Packaged Terminal Air Conditioner/Heat Pump Owner's Manual TABLE OF CONTENTS Safety Precautions 3 Before Operation 7 Introduction 8 Electrical Safety 9 Installation 11 Control Locations 13 Maintenance and Service 21 FOR YOUR RECORDS Write...
... each unit. If you review our chart of Troubleshooting Tips first, you may not need it to call for warranty issues. Packaged Terminal Air Conditioner/Heat Pump Owner's Manual TABLE OF CONTENTS Safety Precautions 3 Before Operation 7 Introduction 8 Electrical Safety 9 Installation 11 Control Locations 13 Maintenance and Service 21 FOR YOUR RECORDS Write...
Owner's Manual (English)
Page 16
...money by switches #3 - #5. This temperature limiting is controlled by limiting the lowest temperature for cooling and the highest temperature for heating. To replace the front grille, place the tabs over the top of the unit and push the bottom of control box.... (23.3° C) 72° F (22.2° C) #6 OFF OFF ON ON #7 OFF ON OFF ON Unit Type Cooling+Electric Heater+Heat Pump Cooling+Electric Heater Heat Pump Only Cooling Only 16 Room Air Conditioner Control Locations Additional Controls • REMOVING THE FRONT GRILLE Additional controls are available after removing the front...
...money by switches #3 - #5. This temperature limiting is controlled by limiting the lowest temperature for cooling and the highest temperature for heating. To replace the front grille, place the tabs over the top of the unit and push the bottom of control box.... (23.3° C) 72° F (22.2° C) #6 OFF OFF ON ON #7 OFF ON OFF ON Unit Type Cooling+Electric Heater+Heat Pump Cooling+Electric Heater Heat Pump Only Cooling Only 16 Room Air Conditioner Control Locations Additional Controls • REMOVING THE FRONT GRILLE Additional controls are available after removing the front...
Owner's Manual (English)
Page 18
... Maximum Length 600 ft (180 m) 900 ft (270 m) 1500 ft (450 m) 2000 ft (610 m) Note: The following figures show wiring schematics for Remote Heat Pump FD2 FD1 DR2 DR1 MS2 MS1 (Molex Housing Spec 396-06V) • REMOTE WALL THERMOSTAT When the wires are not available. • ENERGY SAVER The... energy saver switch #2 is on . The unit control by a remote wall thermostat. Wiring Schematic for heat pump and straight cool units with a switch located at cycle fan to the setting of the room. When the switch is on, the fan is on...
... Maximum Length 600 ft (180 m) 900 ft (270 m) 1500 ft (450 m) 2000 ft (610 m) Note: The following figures show wiring schematics for Remote Heat Pump FD2 FD1 DR2 DR1 MS2 MS1 (Molex Housing Spec 396-06V) • REMOTE WALL THERMOSTAT When the wires are not available. • ENERGY SAVER The... energy saver switch #2 is on . The unit control by a remote wall thermostat. Wiring Schematic for heat pump and straight cool units with a switch located at cycle fan to the setting of the room. When the switch is on, the fan is on...
Owner's Manual (English)
Page 19
... Low Fan LO LI GL GH O W Y R C (Molex Housing Spec 396-09V) Wiring Schematic for Remote Heat Pump • REMOTE WALL THERMOSTAT When the wires are not available. • ENERGY SAVER The energy saver switch #2 is...the unit to operate by knobs are connected, the unit will be turned ON or OFF with electric heat, respectively. This switch is OFF, the unit can be controlled by a remote wall thermostat. The... R C Front Desk Switch Note:The following figures show wiring schematics for heat pump and straight cool units with a switch located at continuous fan to the 24 Volt AC.
... Low Fan LO LI GL GH O W Y R C (Molex Housing Spec 396-09V) Wiring Schematic for Remote Heat Pump • REMOTE WALL THERMOSTAT When the wires are not available. • ENERGY SAVER The energy saver switch #2 is...the unit to operate by knobs are connected, the unit will be turned ON or OFF with electric heat, respectively. This switch is OFF, the unit can be controlled by a remote wall thermostat. The... R C Front Desk Switch Note:The following figures show wiring schematics for heat pump and straight cool units with a switch located at continuous fan to the 24 Volt AC.
Owner's Manual (Español)
Page 1
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. It contains valuable information about your air conditioner. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.
IMPORTANT Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. It contains valuable information about your air conditioner. ENGLISH ESPAÑOL FRANÇAIS http://www.lgservice.com LG PACKAGED TERMINAL LG AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL Please read through this manual.