Use & Care Guide - Page 1
.../W11134241C 30" AND 36" (76.2 AND 91.4 CM) WALL‑MOUNT CANOPY RANGE HOOD
Installation Instructions and Use and Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www...
Use & Care Guide - Page 2
... 4
Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the...
Use & Care Guide - Page 4
... and
canopy glass already installed ■■ Vent transition with local codes. INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Tools Needed ■... Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with back draft dampers installed ■■ Vent cover support ...
Use & Care Guide - Page 5
...part of the range hood and the cooking surface. Cold Weather Installations An additional back draft damper should be installed...or Service" section to cooking
surface
Centerline
Cooking surface
* For non-vented (recirculating) installations
...24" (61 cm) of
canopy to order. Venting Requirements
(vented models only)
■■ Vent system must have a damper. Plastic or metal ...
Use & Care Guide - Page 6
...equivalent feet (meters) for specific requirements in the system. ...Installations
If it is recommended that a qualified electrician determine that the ground path is factory set for installation...Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
Venting Methods
This canopy hood is adequate.
Connect the aluminum wiring to aluminum.
The model...
Use & Care Guide - Page 7
... THROUGH STUDS OR REAR WALL SUPPORT
Vertical Centerline
Horizontal Line
REAR WALL MOUNTING TEMPLATE
CL
ALIGN BOTTOM EDGE WITH PENCIL LINE
INDICATING BOTTOM OF THE HOOD
Installation Height
B
C
A. Fastener... to wall flush to the National Electrical Code or CSA Standards and local codes and ordinances. Disconnect power. 2.
INSTALLATION INSTRUCTIONS
Prepare Location
■■ It is ...
Use & Care Guide - Page 8
... D. Place the assembled air deflector and duct over the exhaust outlet. 2. Vent transition B. 3.5 x 9.5 mm screw
For vented installations only: 1. Remove the grease filter.
Install transition on back of the air deflector. 6. A B
For non-vented (recirculating) installation only:
1.
Vent clamp C. Vent duct E. Reassemble the air deflector to the bottom of hood (if removed for...
Use & Care Guide - Page 9
... connectors and connect black wires (E) together. Bracket B. 4.2 x 8 mm screws C. Replace all light bulbs are secure in terminal box using both upper and lower vent covers, ...or electrical shock.
7. Install terminal box cover. 10. Knockout
C.
Failure to ceiling and install with (2) 4.2 x 8 mm screws.
Check that all parts and panels before servicing. When using UL Listed ...
Use & Care Guide - Page 10
... the blower on the front side of the canopy. Duct cover C. LED lights G. Complete Installation
1.
Press once for On and again for quiet operation. Secure the bottom of the range...blower and light.
Grease filter release handle
10 2. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. For best results, start the hood before cooking...
Use & Care Guide - Page 11
...6 months with normal use steel wool or soap-filled scouring pads.
Cleaning Method:
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. Reinstall the filter by a service technician only. See the "Warranty" section for service contact information.
11 A
4. A. Insert aluminum filter into place.
5. See "Metal Grease Filter" in this section...
Use & Care Guide - Page 12
... YL BK RD WH YL/GN
BK
BU YL RD BU GY BK RD WH YL BR YL/GN
LED Driver
Output:
700mA
(2-15
VDC)
+ - Input: 120 VAC
BK BU
SEL0115572A
Motor Specifications
Power Supply Frequency
120 VAC 60 Hz
Power Absorption
240 W
Motor Resistance (Ω)
Blue/Black
17.7
Blue/Gray
27...
Use & Care Guide - Page 13
... number in Canada.
■■ Features and specifications on our full line of appliances. ■■ Referrals to order replacement parts, we recommend that you can write to local dealers.
■■ Installation information.
■■ Use and maintenance procedures.
■■ Accessory and repair parts sales.
■■ Specialized customer assistance (Spanish...
Use & Care Guide - Page 14
..., detailed description of the problem ■ Proof of purchase, when this limited warranty.
1. Travel or transportation expenses for appliances with electrical or plumbing codes, or correction of the appliance.
9. Removal or reinstallation of the Use and Care Guide.
2. Service or parts for service in fixtures (i.e.
This warranty gives you specific legal rights, and you also...
Warranty Information - Page 1
... you specific legal rights, and you also may have other rights that interfere with published user, operator, or installation instructions.
2....replace the product. Repairs to parts or systems to correct improper product maintenance or installation, installation not in this major appliance, you . Removal or reinstallation of purchase, when this major appliance was purchased.
Service...