Warranty Information
Page 1
... and Canada, this information on the model and serial number label located on how to use of consumables or cleaning products not approved by calling KitchenAid. Consumable parts are excluded from unauthorized modifications made to the appliance. 8. Repairs when your major appliance is used in the country in which it is installed...
... and Canada, this information on the model and serial number label located on how to use of consumables or cleaning products not approved by calling KitchenAid. Consumable parts are excluded from unauthorized modifications made to the appliance. 8. Repairs when your major appliance is used in the country in which it is installed...
Use & Care Guide
Page 2
... safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Install Range Hood Internal Blower Motor 8 Install Range Hood In-Line (External...
... safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Install Range Hood Internal Blower Motor 8 Install Range Hood In-Line (External...
Use & Care Guide
Page 4
...; Vent clamps ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver ■ Scissors Parts supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. Vent cover support brackets ■ 2 - 10 x 50 mm... mm screws ■ 9 - 4.2 x 8 mm screws ■ T20® TORX®† adapter Location Requirements IMPORTANT: Observe all parts are registered trademarks of the range hood. It is located inside the range hood on the model/serial rating plate. Read and follow the instructions...
...; Vent clamps ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver ■ Scissors Parts supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. Vent cover support brackets ■ 2 - 10 x 50 mm... mm screws ■ 9 - 4.2 x 8 mm screws ■ T20® TORX®† adapter Location Requirements IMPORTANT: Observe all parts are registered trademarks of the range hood. It is located inside the range hood on the model/serial rating plate. Read and follow the instructions...
Use & Care Guide
Page 5
...your HVAC professional for specific requirements in your dealer or an authorized parts distributor. Wall cap B. 10" (25.4 cm) round vent 5 Vented Installations Min. For higher ceilings, an Extension Kit Part Number W10352733 is recommended. Venting Requirements ■ Vent system must ... not recommended. NOTE: Flexible vent is needed . Roof Venting Wall Venting A B B A A. The damper should be as close as part of the vent system. Flexible vent creates back pressure and air turbulence that greatly reduce performance. clearance upper cabinet to countertop See Note* X*...
...your HVAC professional for specific requirements in your dealer or an authorized parts distributor. Wall cap B. 10" (25.4 cm) round vent 5 Vented Installations Min. For higher ceilings, an Extension Kit Part Number W10352733 is recommended. Venting Requirements ■ Vent system must ... not recommended. NOTE: Flexible vent is needed . Roof Venting Wall Venting A B B A A. The damper should be as close as part of the vent system. Flexible vent creates back pressure and air turbulence that greatly reduce performance. clearance upper cabinet to countertop See Note* X*...
Use & Care Guide
Page 6
...Length To calculate the length of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Roof caps D. Connect the aluminum wiring to the added ... hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. C. Ensure that the ground path is adequate and in the ...
...Length To calculate the length of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Roof caps D. Connect the aluminum wiring to the added ... hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. C. Ensure that the ground path is adequate and in the ...
Use & Care Guide
Page 8
...: Your range hood requires you to the inside set of mounting holes for the selected motor system. ■ Two 6 mm nuts are blower motor mounting parts in -line (external type) blower motor system. Screw spring clip to purchase either an internal type or an in the blower motor installation packet that...
...: Your range hood requires you to the inside set of mounting holes for the selected motor system. ■ Two 6 mm nuts are blower motor mounting parts in -line (external type) blower motor system. Screw spring clip to purchase either an internal type or an in the blower motor installation packet that...
Use & Care Guide
Page 11
.... Blower mounting screws C. Motor electrical plug Install In-line Blower System NOTE: The blower motor housing can result in -line blower system and seal all parts and panels before servicing. Mounting holes 1. Position the in-line blower motor housing in -line blower housing and range hood. Determine and make the wiring...
.... Blower mounting screws C. Motor electrical plug Install In-line Blower System NOTE: The blower motor housing can result in -line blower system and seal all parts and panels before servicing. Mounting holes 1. Position the in-line blower motor housing in -line blower housing and range hood. Determine and make the wiring...
Use & Care Guide
Page 13
... 2 flat head screws. 3. Disconnect power. 2. A B A. Top of the cover apart and hook them behind the chimney mounting brackets. 2. Connect the vent system and seal all parts and panels before servicing. Slightly spread the sides of terminal box E A B C D F Electrical Shock Hazard Electrically ground blower. A A A. Green, bare or yellow/green wires E. UL listed...
... 2 flat head screws. 3. Disconnect power. 2. A B A. Top of the cover apart and hook them behind the chimney mounting brackets. 2. Connect the vent system and seal all parts and panels before servicing. Slightly spread the sides of terminal box E A B C D F Electrical Shock Hazard Electrically ground blower. A A A. Green, bare or yellow/green wires E. UL listed...
Use & Care Guide
Page 17
...look in your area, you can write to order replacement parts, we recommend that you need to KitchenAid Canada with the same precision used to your correspondence. In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800-807-6777...hearing impaired, limited vision, etc.). ■ Referrals to local dealers, repair parts distributors and service companies. For further assistance If you use only factory specified parts. To locate the KitchenAid designated service company in your nearest designated service center. ASSISTANCE OR SERVICE When calling...
...look in your area, you can write to order replacement parts, we recommend that you need to KitchenAid Canada with the same precision used to your correspondence. In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800-807-6777...hearing impaired, limited vision, etc.). ■ Referrals to local dealers, repair parts distributors and service companies. For further assistance If you use only factory specified parts. To locate the KitchenAid designated service company in your nearest designated service center. ASSISTANCE OR SERVICE When calling...
Use & Care Guide
Page 18
... warranty. If outside the 50 United States and Canada, contact your authorized KitchenAid dealer to know your major appliance for future reference. You will pay for Factory Specified Parts and repair labor to be provided by the customer. The removal and reinstallation...and maintained according to instructions attached to or furnished with the product, KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter "KitchenAid") will need to determine if another warranty applies. Consumable parts are excluded from your major appliance to better help by checking the...
... warranty. If outside the 50 United States and Canada, contact your authorized KitchenAid dealer to know your major appliance for future reference. You will pay for Factory Specified Parts and repair labor to be provided by the customer. The removal and reinstallation...and maintained according to instructions attached to or furnished with the product, KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter "KitchenAid") will need to determine if another warranty applies. Consumable parts are excluded from your major appliance to better help by checking the...
Dimension Guide
Page 1
...: Minimum distance "X": 24" (61 cm) from electric cooking surfaces Minimum distance "X": 30" (76.2 cm) from your dealer or an authorized parts distributor. NOTE: Flexible vent is needed for joining copper to aluminum. ceiling height Max. q If the house has aluminum wiring, follow the procedure...is available from gas cooking surfaces The chimneys can be uniform. See the following chart. For higher ceilings, an Extension Kit Part Number W10352733 is recommended. The range hood exhaust opening width (if installed between the bottom of elbows should be adjusted for ...
...: Minimum distance "X": 24" (61 cm) from electric cooking surfaces Minimum distance "X": 30" (76.2 cm) from your dealer or an authorized parts distributor. NOTE: Flexible vent is needed for joining copper to aluminum. ceiling height Max. q If the house has aluminum wiring, follow the procedure...is available from gas cooking surfaces The chimneys can be uniform. See the following chart. For higher ceilings, an Extension Kit Part Number W10352733 is recommended. The range hood exhaust opening width (if installed between the bottom of elbows should be adjusted for ...