Owners Manual
Page 1
User: BEFORE using this product, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.invacare.com User Manual Invacare XPO2™ Portable Concentrator Models XPO100, XPO100B Dealer: This manual MUST be given to the end user.
User: BEFORE using this product, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.invacare.com User Manual Invacare XPO2™ Portable Concentrator Models XPO100, XPO100B Dealer: This manual MUST be given to the end user.
Owners Manual
Page 2
...BEFORE ATTEMPTING TO USE THIS EQUIPMENT OTHERWISE, INJURY OR DAMAGE MAY OCCUR. ƽ ACCESSORIES WARNING INVACARE PRODUCTS ARE SPECIFICALLY DESIGNED AND MANUFACTURED FOR USE IN CONJUNCTION WITH INVACARE ACCESSORIES. Invacare XPO2™ 2 Part No 1148112 NOTE: Updated versions of this manual can be found at ...www.invacare.com. WARNING ƽ WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE ...
...BEFORE ATTEMPTING TO USE THIS EQUIPMENT OTHERWISE, INJURY OR DAMAGE MAY OCCUR. ƽ ACCESSORIES WARNING INVACARE PRODUCTS ARE SPECIFICALLY DESIGNED AND MANUFACTURED FOR USE IN CONJUNCTION WITH INVACARE ACCESSORIES. Invacare XPO2™ 2 Part No 1148112 NOTE: Updated versions of this manual can be found at ...www.invacare.com. WARNING ƽ WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE ...
Owners Manual
Page 3
... Frequency Interference 9 Polarized Plug Instruction 10 SECTION 2-PACKAGING AND HANDLING .......11 Unpacking 11 Inspection 11 Storage 11 SECTION 3-TECHNICAL DESCRIPTION 12 SECTION 4-XPO2 FEATURES 13 SECTION 5-TYPICAL PRODUCT PARAMETERS .14 Regulatory Listing 16 SECTION 6-OPERATING INSTRUCTIONS ..........17 Introduction 17 Filters 17 Location 18 Recommendations for Optimal... Supplies 19 Checking Charge Level of Internal Battery 21 Charging the Batteries 22 Battery Time Management 26 Prolonging XPO2 Battery Life 26 Powering the XPO2 28 Part No 1148112 3 Invacare XPO2™
... Frequency Interference 9 Polarized Plug Instruction 10 SECTION 2-PACKAGING AND HANDLING .......11 Unpacking 11 Inspection 11 Storage 11 SECTION 3-TECHNICAL DESCRIPTION 12 SECTION 4-XPO2 FEATURES 13 SECTION 5-TYPICAL PRODUCT PARAMETERS .14 Regulatory Listing 16 SECTION 6-OPERATING INSTRUCTIONS ..........17 Introduction 17 Filters 17 Location 18 Recommendations for Optimal... Supplies 19 Checking Charge Level of Internal Battery 21 Charging the Batteries 22 Battery Time Management 26 Prolonging XPO2 Battery Life 26 Powering the XPO2 28 Part No 1148112 3 Invacare XPO2™
Owners Manual
Page 5
... injury or death. SIGNAL WORD DANGER WARNING CAUTION MEANING Danger indicates an imminently hazardous situation which could result in oxygen enriched air. Part No 1148112 5 Invacare XPO2™ NO SMOKING signs should be prominently displayed.
... injury or death. SIGNAL WORD DANGER WARNING CAUTION MEANING Danger indicates an imminently hazardous situation which could result in oxygen enriched air. Part No 1148112 5 Invacare XPO2™ NO SMOKING signs should be prominently displayed.
Owners Manual
Page 6
... alternate source of supplemental oxygen in household waste Invacare XPO2™ 6 Part No 1148112 Consult your dealer/provider. Battery packs should be used as an oxygen supplement and is to use or order the use ...
... alternate source of supplemental oxygen in household waste Invacare XPO2™ 6 Part No 1148112 Consult your dealer/provider. Battery packs should be used as an oxygen supplement and is to use or order the use ...
Owners Manual
Page 7
...Refer servicing to ensure the safe installation, assembly and operation of electric shock. DO NOT use of this product. Ꮨ DANGER Risk of the XPO2 Portable Concentrator these instructions MUST be followed. ƽ WARNING This section contains important information for product that has fallen into water or other oxygen equipment... operation and use any lubricants unless recommended by the physician's prescription, the concentrator MUST be kept away from the bath. Part No 1148112 7 Invacare XPO2™ Unplug IMMEDIATELY. DO NOT come in another room at least seven feet from the...
...Refer servicing to ensure the safe installation, assembly and operation of electric shock. DO NOT use of this product. Ꮨ DANGER Risk of the XPO2 Portable Concentrator these instructions MUST be followed. ƽ WARNING This section contains important information for product that has fallen into water or other oxygen equipment... operation and use any lubricants unless recommended by the physician's prescription, the concentrator MUST be kept away from the bath. Part No 1148112 7 Invacare XPO2™ Unplug IMMEDIATELY. DO NOT come in another room at least seven feet from the...
Owners Manual
Page 8
...are unable to hear and/or feel the oxygen pulse, consult your equipment provider and/or your physician IMMEDIATELY. Outdoor use of the XPO2 MUST be conducted with AC power adapters provided. DO NOT use . DO NOT move or relocate concentrator by any type of any opening... heaters, stoves and similar electrical appliances. Make sure XPO2 is not working properly, if it has been dropped or damaged, or dropped into any spark near medical oxygen equipment. Invacare XPO2™ 8 Part No 1148112 Operating Information The XPO2 cannot be left unattended when plugged in use extension ...
...are unable to hear and/or feel the oxygen pulse, consult your equipment provider and/or your physician IMMEDIATELY. Outdoor use of the XPO2 MUST be conducted with AC power adapters provided. DO NOT use . DO NOT move or relocate concentrator by any type of any opening... heaters, stoves and similar electrical appliances. Make sure XPO2 is not working properly, if it has been dropped or damaged, or dropped into any spark near medical oxygen equipment. Invacare XPO2™ 8 Part No 1148112 Operating Information The XPO2 cannot be left unattended when plugged in use extension ...
Owners Manual
Page 9
...or cold automobile or in other similar, high or low, temperature environments. Part No 1148112 9 Invacare XPO2™ Only professionals of 5 minutes. NEVER allow the XPO2 to comply with a humidifier may reduce maximum product life. When your automobile is not designed ... a reasonable protection against electromagnetic interference in an upright position. These limits are designed to minimize routine preventive maintenance. Invacare recommends the XPO2 not be used with a humidifier. Radio Frequency Interference This equipment has been tested and found to be used in...
...or cold automobile or in other similar, high or low, temperature environments. Part No 1148112 9 Invacare XPO2™ Only professionals of 5 minutes. NEVER allow the XPO2 to comply with a humidifier may reduce maximum product life. When your automobile is not designed ... a reasonable protection against electromagnetic interference in an upright position. These limits are designed to minimize routine preventive maintenance. Invacare recommends the XPO2 not be used with a humidifier. Radio Frequency Interference This equipment has been tested and found to be used in...
Owners Manual
Page 10
...standards. Close supervision is connected. A change in a polarized outlet only one blade is wider than the other device(s) stops, then the XPO2 is used near children or physically‐challenged individuals. Polarized Plug Instruction As a safety feature, this safety feature. DO NOT attempt to ... should be required for patients using this product is causing the interference. If it still does not fit, contact a qualified electrician. Invacare XPO2™ 10 Part No 1148112 If the plug does not fit fully in parallel or series with the other ). Be aware that...
...standards. Close supervision is connected. A change in a polarized outlet only one blade is wider than the other device(s) stops, then the XPO2 is used near children or physically‐challenged individuals. Polarized Plug Instruction As a safety feature, this safety feature. DO NOT attempt to ... should be required for patients using this product is causing the interference. If it still does not fit, contact a qualified electrician. Invacare XPO2™ 10 Part No 1148112 If the plug does not fit fully in parallel or series with the other ). Be aware that...
Owners Manual
Page 11
... contact your local dealer. 2. Inspection Inspect/examine exterior of packaged concentrator. Part No 1148112 11 Invacare XPO2™ DO NOT place objects on top of the oxygen concentrator and accessories for storage or return shipment. The Invacare XPO2 Portable Oxygen Concentrator packaging contains the following items (as shown below). Storage 1. Inspect all containers and...
... contact your local dealer. 2. Inspection Inspect/examine exterior of packaged concentrator. Part No 1148112 11 Invacare XPO2™ DO NOT place objects on top of the oxygen concentrator and accessories for storage or return shipment. The Invacare XPO2 Portable Oxygen Concentrator packaging contains the following items (as shown below). Storage 1. Inspect all containers and...
Owners Manual
Page 12
... where it is delivered to the patient in a vehicle or other mobile environment. SECTION 3-TECHNICAL DESCRIPTION SECTION 3-TECHNICAL DESCRIPTION The Invacare portable concentrator is to be used by the patient in a home environment, in an institutional environment or in specific volumes during ...the inhalation portion of a nasal cannula. Ambient air enters the device, is delivered to 95.6%. Invacare XPO2™ 12 Part No 1148112 The oxygen is filtered and then compressed. Device standard power options include an AC to DC switching...
... where it is delivered to the patient in a vehicle or other mobile environment. SECTION 3-TECHNICAL DESCRIPTION SECTION 3-TECHNICAL DESCRIPTION The Invacare portable concentrator is to be used by the patient in a home environment, in an institutional environment or in specific volumes during ...the inhalation portion of a nasal cannula. Ambient air enters the device, is delivered to 95.6%. Invacare XPO2™ 12 Part No 1148112 The oxygen is filtered and then compressed. Device standard power options include an AC to DC switching...
Owners Manual
Page 13
Oxygen Outlet Port Flow Setting/Pulse Indicators On/Off Button Battery Gauge Battery Status Button Input Power Connector Flow Selection Button to decrease flow rate Alarm Indicator Flow Selection Button to familiarize yourself with the locations of the XPO2 features and controls. SECTION 4-XPO2 FEATURES SECTION 4-XPO2 FEATURES Please review the figures below to increase flow rate Air Exhaust Grid Supplemental Battery Pack Air Intake FIGURE 4.1 XPO2 Features Part No 1148112 13 Invacare XPO2™
Oxygen Outlet Port Flow Setting/Pulse Indicators On/Off Button Battery Gauge Battery Status Button Input Power Connector Flow Selection Button to decrease flow rate Alarm Indicator Flow Selection Button to familiarize yourself with the locations of the XPO2 features and controls. SECTION 4-XPO2 FEATURES SECTION 4-XPO2 FEATURES Please review the figures below to increase flow rate Air Exhaust Grid Supplemental Battery Pack Air Intake FIGURE 4.1 XPO2 Features Part No 1148112 13 Invacare XPO2™
Owners Manual
Page 14
... DC Power Supply: 11-16 VDC 1.0 amps at 120 VAC 3.3 amps at 18 VDC < 45dBA weighted Up to 10,000 ft (3046 m) above sea level Invacare XPO2™ 14 Part No 1148112 SECTION 5-TYPICAL PRODUCT PARAMETERS SECTION 5-TYPICAL PRODUCT PARAMETERS Direct Current Type BF equipment Attention -
... DC Power Supply: 11-16 VDC 1.0 amps at 120 VAC 3.3 amps at 18 VDC < 45dBA weighted Up to 10,000 ft (3046 m) above sea level Invacare XPO2™ 14 Part No 1148112 SECTION 5-TYPICAL PRODUCT PARAMETERS SECTION 5-TYPICAL PRODUCT PARAMETERS Direct Current Type BF equipment Attention -
Owners Manual
Page 15
Bolus Volume Ranges From 300 - 840cc settings 1 to 5. setting 5 Part No 1148112 15 Invacare XPO2™ settings 1, 2 and 3 45 minutes (max) - Dimensions: 10" high x 7" wide x 4" deep (25.4 cm high x 17.8 cm wide x 10.2 cm wide) Weight: 6.0 lbs (2.72 kg); 1.3 lbs (0....
Bolus Volume Ranges From 300 - 840cc settings 1 to 5. setting 5 Part No 1148112 15 Invacare XPO2™ settings 1, 2 and 3 45 minutes (max) - Dimensions: 10" high x 7" wide x 4" deep (25.4 cm high x 17.8 cm wide x 10.2 cm wide) Weight: 6.0 lbs (2.72 kg); 1.3 lbs (0....
Owners Manual
Page 16
CSA 601.1 M90 Invacare XPO2™ 16 Part No 1148112 IEC 61000-3-2:2005 IEC 61000-3-3:2005 UL 60601-1, 1st ed. SECTION 5-TYPICAL PRODUCT PARAMETERS Regulatory Listing ETL certified complying with: EN 55011:1998 CISPR 11: 2003 IEC 60601-1; 2nd ed. 2005 IEC 60601-1-2; 2.1 ed.
CSA 601.1 M90 Invacare XPO2™ 16 Part No 1148112 IEC 61000-3-2:2005 IEC 61000-3-3:2005 UL 60601-1, 1st ed. SECTION 5-TYPICAL PRODUCT PARAMETERS Regulatory Listing ETL certified complying with: EN 55011:1998 CISPR 11: 2003 IEC 60601-1; 2nd ed. 2005 IEC 60601-1-2; 2.1 ed.
Owners Manual
Page 17
...output. This filter prevents hair and other large particles in this filter is clean, dry and properly positioned. Before you operate the XPO2, make sure you operate your equipment provider. This operator's manual will acquaint you have limited their portability. To clean/replace the ...enters the XPO2 through an air intake filter located under the cover on page 37. Until now, the size and weight of traditional oxygen concentrator's have any questions, please contact your unit. Should you with the XPO2 and its accessories. Part No 1148112 17 Invacare XPO2™ ...
...output. This filter prevents hair and other large particles in this filter is clean, dry and properly positioned. Before you operate the XPO2, make sure you operate your equipment provider. This operator's manual will acquaint you have limited their portability. To clean/replace the ...enters the XPO2 through an air intake filter located under the cover on page 37. Until now, the size and weight of traditional oxygen concentrator's have any questions, please contact your unit. Should you with the XPO2 and its accessories. Part No 1148112 17 Invacare XPO2™ ...
Owners Manual
Page 18
... from walls, draperies, furniture, and the like . Up to 24 hours per day when connected to AC or DC power adapter. Locate and position the XPO2 in a well ventilated space so that the air intake and the air exhausts are not obstructed. Smoke, pollutant and fume free. No confined spaces (example...
... from walls, draperies, furniture, and the like . Up to 24 hours per day when connected to AC or DC power adapter. Locate and position the XPO2 in a well ventilated space so that the air intake and the air exhausts are not obstructed. Smoke, pollutant and fume free. No confined spaces (example...
Owners Manual
Page 19
... alarm sounds when the battery power is located inside the XPO2. Use of other non approved power supplies with the XPO2 portable concentrator. Part No 1148112 19 Invacare XPO2™ SECTION 6-OPERATING INSTRUCTIONS Power Supplies ƽ WARNING Use only Invacare specified power supplies with the XPO2 can cause damage and/or injury and will allow the...
... alarm sounds when the battery power is located inside the XPO2. Use of other non approved power supplies with the XPO2 portable concentrator. Part No 1148112 19 Invacare XPO2™ SECTION 6-OPERATING INSTRUCTIONS Power Supplies ƽ WARNING Use only Invacare specified power supplies with the XPO2 can cause damage and/or injury and will allow the...
Owners Manual
Page 20
...8208;volt DC outlet. This DC power adapter can be powered by a supplemental battery pack. The supplemental battery pack will allow the XPO2 to the power input connector of additional run time. NOTE: The supplemental battery cannot be used to 3.5 hours of the unit. ...Battery Gauge Battery Status Button Supplemental Battery Pack FIGURE 6.1 Power Supplies Invacare XPO2™ 20 Part No 1148112 SECTION 6-OPERATING INSTRUCTIONS DC Power Adapter: A DC power adapter allows the XPO2 to be connected to charge the internal battery.
...8208;volt DC outlet. This DC power adapter can be powered by a supplemental battery pack. The supplemental battery pack will allow the XPO2 to the power input connector of additional run time. NOTE: The supplemental battery cannot be used to 3.5 hours of the unit. ...Battery Gauge Battery Status Button Supplemental Battery Pack FIGURE 6.1 Power Supplies Invacare XPO2™ 20 Part No 1148112 SECTION 6-OPERATING INSTRUCTIONS DC Power Adapter: A DC power adapter allows the XPO2 to be connected to charge the internal battery.
Owners Manual
Page 21
Turn On the XPO2 by pressing and holding the On/Off button. 2. Press and hold the battery status button located on the keypad. Lesser charges will illuminate and stay ... indicator lights. NOTE: Pressing the battery status button will illuminate the battery gauge and indicate the charge level of Internal Battery Part No 1148112 21 Invacare XPO2™ Battery Gauge Battery Status Button FIGURE 6.2 Checking Charge Level of the internal battery. SECTION 6-OPERATING INSTRUCTIONS Checking Charge Level of Internal Battery NOTE: For...
Turn On the XPO2 by pressing and holding the On/Off button. 2. Press and hold the battery status button located on the keypad. Lesser charges will illuminate and stay ... indicator lights. NOTE: Pressing the battery status button will illuminate the battery gauge and indicate the charge level of Internal Battery Part No 1148112 21 Invacare XPO2™ Battery Gauge Battery Status Button FIGURE 6.2 Checking Charge Level of the internal battery. SECTION 6-OPERATING INSTRUCTIONS Checking Charge Level of Internal Battery NOTE: For...