User Guide
Page 6
The contents of each server system are three versions of this server system: the Intel® Server Systems SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR (SAS/SATA versions) and the Intel® Server System SR2520SAF/SR2520SAFR (SATA only version). Intel® Server System SR2520SAX/SR2520SAXR Contents Your Intel® Server System SR2520SAX/SR2520SAXR ships with the following items: • Intel® Server Board S5000VSA (SATA SKU), installed in the server system • One 600 W hot-swap power...
The contents of each server system are three versions of this server system: the Intel® Server Systems SR2520SAX/ SR2520SAXS and SR2520SAXR/SR2520SAXSR (SAS/SATA versions) and the Intel® Server System SR2520SAF/SR2520SAFR (SATA only version). Intel® Server System SR2520SAX/SR2520SAXR Contents Your Intel® Server System SR2520SAX/SR2520SAXR ships with the following items: • Intel® Server Board S5000VSA (SATA SKU), installed in the server system • One 600 W hot-swap power...
User Guide
Page 8
...; Server System SR2520SAF/SR2520SAFR Contents Your Intel® Server System SR2520SAF/SR2520SAFR ships with the following items: • Intel® Server Board S5000VSA (4 DIMM SKU), installed in the server system • One 600 W fixed power supply module, installed in the server system • Two 80mm system fans, installed in the server system • One 60mm system fan, installed in the server system • CPU air duct, installed in the server system...
...; Server System SR2520SAF/SR2520SAFR Contents Your Intel® Server System SR2520SAF/SR2520SAFR ships with the following items: • Intel® Server Board S5000VSA (4 DIMM SKU), installed in the server system • One 600 W fixed power supply module, installed in the server system • Two 80mm system fans, installed in the server system • One 60mm system fan, installed in the server system • CPU air duct, installed in the server system...
User Guide
Page 14
... Card 49 Installing and Removing the Server Board 50 Installing the Server Board 50 Removing the Server Board 51 Replacing the Backup Battery 52 Replacing the Redundant Power Supply (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) ...54 Replacing the Fixed Power Supply (SR2520SAF/SR2520SAFR 55 Replacing the Front Panel Board 57 Replacing a System Fan ...60 Installing and Removing...
... Card 49 Installing and Removing the Server Board 50 Installing the Server Board 50 Removing the Server Board 51 Replacing the Backup Battery 52 Replacing the Redundant Power Supply (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) ...54 Replacing the Fixed Power Supply (SR2520SAF/SR2520SAFR 55 Replacing the Front Panel Board 57 Replacing a System Fan ...60 Installing and Removing...
User Guide
Page 15
... Technical Reference 71 Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR 71 Cable Routing (SR2520SAF/SR2520SAFR 72 600W Single Power Supply Input Voltages 73 600W Single Power Supply Output Voltages 73 System Environmental Specifications 74 Appendix B: LED Decoder (SR2520SAX /SR2520SAXS and SR2520SAXR/ SR2520SAXSR Only 75 Appendix C: Getting Help 81 World...) ...90 Korean Compliance (RRL 91 Regulated Specified Components 91 Restriction of Hazardous Substances (RoHS) Compliance 92 End-of the Operating System 99 Intel® Server System SR2520SA User's Guide xv
... Technical Reference 71 Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR 71 Cable Routing (SR2520SAF/SR2520SAFR 72 600W Single Power Supply Input Voltages 73 600W Single Power Supply Output Voltages 73 System Environmental Specifications 74 Appendix B: LED Decoder (SR2520SAX /SR2520SAXS and SR2520SAXR/ SR2520SAXSR Only 75 Appendix C: Getting Help 81 World...) ...90 Korean Compliance (RRL 91 Regulated Specified Components 91 Restriction of Hazardous Substances (RoHS) Compliance 92 End-of the Operating System 99 Intel® Server System SR2520SA User's Guide xv
User Guide
Page 19
... Figure 20. Removing Hot-swap Disk Carrier from Drive Carrier (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR 39 Figure 28. Server Board Connector and Component Locations 9 Figure 5. BIOS Select Jumper 10 Figure 6. Intel® Server System SR2520SAF/SR2520SAFR Back Panel Connectors 13 Figure 9. Optional Peripherals (SR2520SAF/SR2520SAFR 18 Figure 14. Front View with Bezel 24 Figure 15. Removing the...
... Figure 20. Removing Hot-swap Disk Carrier from Drive Carrier (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR 39 Figure 28. Server Board Connector and Component Locations 9 Figure 5. BIOS Select Jumper 10 Figure 6. Intel® Server System SR2520SAF/SR2520SAFR Back Panel Connectors 13 Figure 9. Optional Peripherals (SR2520SAF/SR2520SAFR 18 Figure 14. Front View with Bezel 24 Figure 15. Removing the...
User Guide
Page 20
... and SR2520SAXR/SR2520SAXSR 55 Figure 44. Removing the Fan Module 60 Figure 51. Installing a Fan into the Fan Module 61 Figure 53. Installing the Fan Module 62 Figure 54. Clear Password Jumper 68 Figure 57. Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) 71 Figure 59. Cable Routing (SR2520SAF/SR2520SAFR 72 xx Intel® Server System SR2520SA...
... and SR2520SAXR/SR2520SAXSR 55 Figure 44. Removing the Fan Module 60 Figure 51. Installing a Fan into the Fan Module 61 Figure 53. Installing the Fan Module 62 Figure 54. Clear Password Jumper 68 Figure 57. Cable Routing (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR) 71 Figure 59. Cable Routing (SR2520SAF/SR2520SAFR 72 xx Intel® Server System SR2520SA...
User Guide
Page 26
... and SR2520SAXR/ SR2520SAXSR: Eight DIMM sockets supporting stacked 533/ 667 MHz compliant FBDIMM memory (up to 16 GB of total system memory) • SR2520SAF/SR2520SAFR: Four DIMM sockets supporting stacked 533/667 MHz compliant FBDIMM memory (up to 8 GB of total system memory) Intel® 5000V chipset, consisting of the server system. max chassis weight Intel® Server Board...
... and SR2520SAXR/ SR2520SAXSR: Eight DIMM sockets supporting stacked 533/ 667 MHz compliant FBDIMM memory (up to 16 GB of total system memory) • SR2520SAF/SR2520SAFR: Four DIMM sockets supporting stacked 533/667 MHz compliant FBDIMM memory (up to 8 GB of total system memory) Intel® 5000V chipset, consisting of the server system. max chassis weight Intel® Server Board...
User Guide
Page 30
System Cooling Fans C. Front Panel H. Hard Drive Bays (drives not included) Figure 3. D C B A E K J I . Control Panel (standard control panel shown) I H G A F AF001663 A. Optical Drive Bay J. Server Board E. Rack Handles B. Fixed Power Supply F. Power Distribution Board G. ChassisComponents (SR2520SAF/SR2520SAFR) 8 Intel® Server System SR2520SA User's Guide CPU Air Duct D. Slimline Floppy Drive K.
System Cooling Fans C. Front Panel H. Hard Drive Bays (drives not included) Figure 3. D C B A E K J I . Control Panel (standard control panel shown) I H G A F AF001663 A. Optical Drive Bay J. Server Board E. Rack Handles B. Fixed Power Supply F. Power Distribution Board G. ChassisComponents (SR2520SAF/SR2520SAFR) 8 Intel® Server System SR2520SA User's Guide CPU Air Duct D. Slimline Floppy Drive K.
User Guide
Page 35
... and SR2520SAXR/ SR2520SAXSR Back Panel Connectors Intel® Server System SR2520SA User's Guide 13 Back Panel Connectors A BC D E F I . Power Supply 1 Receptacle B. NIC1 and NIC2 (10/100/1000 Mb) F. Power Supply 2 Module E. Mouse/Keyboard F. Video I H G AF001475 A. Power Supply 1 Module C. PCI Expansion Slots I AF001441 A. Power Supply 2 Receptacle D. USB Ports H. NIC1 and NIC2 (10/100/1000 Mb) H. Intel® Server System SR2520SAF/SR2520SAFR...
... and SR2520SAXR/ SR2520SAXSR Back Panel Connectors Intel® Server System SR2520SA User's Guide 13 Back Panel Connectors A BC D E F I . Power Supply 1 Receptacle B. NIC1 and NIC2 (10/100/1000 Mb) F. Power Supply 2 Module E. Mouse/Keyboard F. Video I H G AF001475 A. Power Supply 1 Module C. PCI Expansion Slots I AF001441 A. Power Supply 2 Receptacle D. USB Ports H. NIC1 and NIC2 (10/100/1000 Mb) H. Intel® Server System SR2520SAF/SR2520SAFR...
User Guide
Page 37
... is available in navigating through the SATA_SGPIO connector on the server board when a cable is attached between this connector on the server board and to the backplane I2C interface. The fixed model has order code SR2520SAF/SR2520SAFR. SATA The Intel® Server Systems SR2520SAF/SR2520SAFR and SR2520SAX/SR2520SAXR provide an embedded SATA controller that is located at the...
... is available in navigating through the SATA_SGPIO connector on the server board when a cable is attached between this connector on the server board and to the backplane I2C interface. The fixed model has order code SR2520SAF/SR2520SAFR. SATA The Intel® Server Systems SR2520SAF/SR2520SAFR and SR2520SAX/SR2520SAXR provide an embedded SATA controller that is located at the...
User Guide
Page 40
...SR2520SAXR/SR2520SAXSR) The drives must be purchased separately. Slimline floppy drive C. A B AF001662 . Optical drive bay (Optional; For instructions on design that allows for maximum airflow through the server chassis. A B C AF001440 . A. Slimline floppy drive B. Peripheral Devices The server system... hard drive and optical drive area. The following figure shows the available options. Optional Peripherals (SR2520SAF/SR2520SAFR) 18 Intel® Server System SR2520SA User's Guide Bezels The optional front bezel provides a snap-on installing either of the front ...
...SR2520SAXR/SR2520SAXSR) The drives must be purchased separately. Slimline floppy drive C. A B AF001662 . Optical drive bay (Optional; For instructions on design that allows for maximum airflow through the server chassis. A B C AF001440 . A. Slimline floppy drive B. Peripheral Devices The server system... hard drive and optical drive area. The following figure shows the available options. Optional Peripherals (SR2520SAF/SR2520SAFR) 18 Intel® Server System SR2520SA User's Guide Bezels The optional front bezel provides a snap-on installing either of the front ...
User Guide
Page 41
... "Installing and Removing a Hot-swap Hard Drive (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR)" or "Installing and Removing a Fixed Hard Drive (SR2520SAF/SR2520SAFR)". Intel provides three options to run at a maximum ambient temperature of supported hardware. Intel® Server System SR2520SA User's Guide 19 Note: The Intel® Server System SR2520SA does not support all SAS or Serial ATA (SATA) hard...
... "Installing and Removing a Hot-swap Hard Drive (SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR)" or "Installing and Removing a Fixed Hard Drive (SR2520SAF/SR2520SAFR)". Intel provides three options to run at a maximum ambient temperature of supported hardware. Intel® Server System SR2520SA User's Guide 19 Note: The Intel® Server System SR2520SA does not support all SAS or Serial ATA (SATA) hard...
User Guide
Page 53
... the list of tested DIMMs. Note: The Intel® Server System SR2520SAF/SR2520SAFR only has four DIMM sockets. For instructions, see Figure 21). Turn off the server. 3. Disconnect the AC power cord(s) from the center of the memory requirements and options. See "Memory" for a link to the server. Intel® Server System SR2520SA User's Guide 31 Locate the DIMM...
... the list of tested DIMMs. Note: The Intel® Server System SR2520SAF/SR2520SAFR only has four DIMM sockets. For instructions, see Figure 21). Turn off the server. 3. Disconnect the AC power cord(s) from the center of the memory requirements and options. See "Memory" for a link to the server. Intel® Server System SR2520SA User's Guide 31 Locate the DIMM...
User Guide
Page 63
...it . 8. Lift the drive from the server system. 4. Install the server system cover. Plug all hard drives. Installing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the front bezel if it is installed in the carrier into the server system. When the black lever begins to lock ...supported hardware. For instructions, see "Installing the System Cover". 10. (Optional) Install the front bezel. Intel® Server System SR2520SA User's Guide 41 Removing a SAS or SATA Hot-swap Hard Disk Drive (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) 1. Note: For proper airflow, the...
...it . 8. Lift the drive from the server system. 4. Install the server system cover. Plug all hard drives. Installing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the front bezel if it is installed in the carrier into the server system. When the black lever begins to lock ...supported hardware. For instructions, see "Installing the System Cover". 10. (Optional) Install the front bezel. Intel® Server System SR2520SA User's Guide 41 Removing a SAS or SATA Hot-swap Hard Disk Drive (SR2520SAX/SR2520SAXS and SR2520SAXR/ SR2520SAXSR) 1. Note: For proper airflow, the...
User Guide
Page 64
... "C" in place (see "Installing the System Cover". 7. A B C AF001665 Figure 29. Note: Install screws into the server system with the four screws you will use them to install the hard drive bracket back into the Server System (SR2520SAF/SR2520SAFR) 6. you removed in step 2 (see... 5. Install the server system cover. Remove the four screws securing the hard drive bracket in the figure below ). Installing Fixed Hard Drive(s) into the server system. 3. 2. Save the screws; Install the hard drive(s) into the server. 42 Intel® Server System SR2520SA User's Guide ...
... "C" in place (see "Installing the System Cover". 7. A B C AF001665 Figure 29. Note: Install screws into the server system with the four screws you will use them to install the hard drive bracket back into the Server System (SR2520SAF/SR2520SAFR) 6. you removed in step 2 (see... 5. Install the server system cover. Remove the four screws securing the hard drive bracket in the figure below ). Installing Fixed Hard Drive(s) into the server system. 3. 2. Save the screws; Install the hard drive(s) into the server. 42 Intel® Server System SR2520SA User's Guide ...
User Guide
Page 65
... drive cage. 3. Install the server system cover. Removing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the drive from the Server System (SR2520SAF/SR2520SAFR) 4. A B AF001646 Figure 30. Using the four screws you removed in an anti-static bag. Remove the four screws that attach the hard drive cage to the drive cage. Intel® Server System SR2520SA User's Guide 43...
... drive cage. 3. Install the server system cover. Removing a Fixed Hard Disk Drive (SR2520SAF/ SR2520SAFR) 1. Remove the drive from the Server System (SR2520SAF/SR2520SAFR) 4. A B AF001646 Figure 30. Using the four screws you removed in an anti-static bag. Remove the four screws that attach the hard drive cage to the drive cage. Intel® Server System SR2520SA User's Guide 43...
User Guide
Page 77
... supply cage until it fails. Install the server system cover. Replacing the Fixed Power Supply (SR2520SAF/ SR2520SAFR) Caution: The power supply is integrated into it clicks into the server. Observe the safety and ESD precautions at the...System Cover". 7. Intel® Server System SR2520SA User's Guide 55 A AF001456 Figure 43. Remove the power supply bracket by pressing the power button, and unplug the AC power cord from the chassis tab (see letter "B" in the figure below ). 3. Insert the replacement power supply module into the Server System (SR2520SAX/SR2520SAXS and SR2520SAXR...
... supply cage until it fails. Install the server system cover. Replacing the Fixed Power Supply (SR2520SAF/ SR2520SAFR) Caution: The power supply is integrated into it clicks into the server. Observe the safety and ESD precautions at the...System Cover". 7. Intel® Server System SR2520SA User's Guide 55 A AF001456 Figure 43. Remove the power supply bracket by pressing the power button, and unplug the AC power cord from the chassis tab (see letter "B" in the figure below ). 3. Insert the replacement power supply module into the Server System (SR2520SAX/SR2520SAXS and SR2520SAXR...
User Guide
Page 78
Slide the replacement power supply into the chassis (see letter "A" in the figure below ). 9. Removing Power Supply Module from the Server System (SR2520SAF/SR2520SAFR) 7. Make sure the power supply is seated behind the chassis tab (see letter "C" in the figure below ). 8. Install the power supply bracket using the two screws you removed in step 4 (see letter "B" in the figure below). 56 Intel® Server System SR2520SA User's Guide B A D C AF001667 Figure 44.
Slide the replacement power supply into the chassis (see letter "A" in the figure below ). 9. Removing Power Supply Module from the Server System (SR2520SAF/SR2520SAFR) 7. Make sure the power supply is seated behind the chassis tab (see letter "C" in the figure below ). 8. Install the power supply bracket using the two screws you removed in step 4 (see letter "B" in the figure below). 56 Intel® Server System SR2520SA User's Guide B A D C AF001667 Figure 44.
User Guide
Page 79
... power cord from the system or wall outlet. 1. Intel® Server System SR2520SA User's Guide 57 Plug all peripheral devices and the AC power cable(s). 3. Remove the front bezel if it is NOT hot swappable. Power down the server and unplug all peripheral devices and the AC power cable(s) into the Server System (SR2520SAF/SR2520SAFR) 10. Caution: The...
... power cord from the system or wall outlet. 1. Intel® Server System SR2520SA User's Guide 57 Plug all peripheral devices and the AC power cable(s). 3. Remove the front bezel if it is NOT hot swappable. Power down the server and unplug all peripheral devices and the AC power cable(s) into the Server System (SR2520SAF/SR2520SAFR) 10. Caution: The...
User Guide
Page 94
... H Fan #1 Power I Fan #2 Power J Fan #3 Power K HDD 0 to Server Board SATA 0 L HDD 1 to Server Board SATA 1 M HDD 2 to Server Board SAS 0/SATA 2 N HDD 3 to Server Board SAS 1/SATA 3 O HDD 4 to Server Board SAS 2/SATA 4 P HDD 5 to determine the correct cable routing. Cable Routing (SR2520SAF/SR2520SAFR) AF001664 72 Intel® Server System SR2520SA User's Guide Use the figures below to...
... H Fan #1 Power I Fan #2 Power J Fan #3 Power K HDD 0 to Server Board SATA 0 L HDD 1 to Server Board SATA 1 M HDD 2 to Server Board SAS 0/SATA 2 N HDD 3 to Server Board SAS 1/SATA 3 O HDD 4 to Server Board SAS 2/SATA 4 P HDD 5 to determine the correct cable routing. Cable Routing (SR2520SAF/SR2520SAFR) AF001664 72 Intel® Server System SR2520SA User's Guide Use the figures below to...