Product Specification
Page 11
SR1530CL/SR1530CLR (SATA) Revision 2.2 3 Intel order number D71005-005 Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR 1.3 System Components D C B A Introduction K J I A E F G H AF001185 A Rack handles (two) B PCI cooling fan C Processor air duct D PCI add-in card bracket E System memory DIMM sockets F Power supply G Processor sockets (two) H System blower fans (two) I Hard drives (two) J Control panel K Slimline optical drive Figure 3. Major System Components -
SR1530CL/SR1530CLR (SATA) Revision 2.2 3 Intel order number D71005-005 Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR 1.3 System Components D C B A Introduction K J I A E F G H AF001185 A Rack handles (two) B PCI cooling fan C Processor air duct D PCI add-in card bracket E System memory DIMM sockets F Power supply G Processor sockets (two) H System blower fans (two) I Hard drives (two) J Control panel K Slimline optical drive Figure 3. Major System Components -
Product Specification
Page 12
SR1530HCL/SR1530HCLR (SATA) and SR1530HCLS/SR1530HCLSR (SAS) 4 Revision 2.2 Intel order number D71005-005 Major System Components - Introduction Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR F E D C B A L G H K J A Rack handles (two) B PCI air baffle C System blower fans (two) D Processor air duct E System memory DIMM sockets F PCI riser assembly I A AF001612 G Server board H Power supply I Front panel board J Control panel K Hot-swap hard drives (three) L Slimline optical drive Figure 4.
SR1530HCL/SR1530HCLR (SATA) and SR1530HCLS/SR1530HCLSR (SAS) 4 Revision 2.2 Intel order number D71005-005 Major System Components - Introduction Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR F E D C B A L G H K J A Rack handles (two) B PCI air baffle C System blower fans (two) D Processor air duct E System memory DIMM sockets F PCI riser assembly I A AF001612 G Server board H Power supply I Front panel board J Control panel K Hot-swap hard drives (three) L Slimline optical drive Figure 4.
Product Specification
Page 15
...memory, and add-in the table. It provides integrated management features, including over the input voltage ranges shown in cards. 1.8 Rack and Cabinet Mounting Options The Intel® Server System SR1530CL/SR1530CLR (SATA) can be configured to mount the system into a standard 19-inch by up to 30-inch deep server cabinets. The Intel® Server System...power supply to exceed the specified limits. Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Introduction 1.6 Power Sub-System The power sub-system consists of an input voltage below 85 ...
...memory, and add-in the table. It provides integrated management features, including over the input voltage ranges shown in cards. 1.8 Rack and Cabinet Mounting Options The Intel® Server System SR1530CL/SR1530CLR (SATA) can be configured to mount the system into a standard 19-inch by up to 30-inch deep server cabinets. The Intel® Server System...power supply to exceed the specified limits. Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Introduction 1.6 Power Sub-System The power sub-system consists of an input voltage below 85 ...
Product Specification
Page 23
... (SATA) and SR1530HCLS/SR1530HCLSR (SAS) Fan System fan blower 1 System fan blower 2 PCI cooling fan (SR1530CL only) Table 14. Cooling Zones Cooling Zone CPU1 CPU2 PCI Greatest Cooling Influence Primary cooling for CPU1 and the system memory Primary cooling for hard HDD1, CPU2, the...air pressure. Revision 2.2 15 Intel order number D71005-005 The baffle is mounted into three stand-offs with one end fitting under the back edge of the hard drive bay. Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Cooling Sub-System A B AF001648 Figure 11....
... (SATA) and SR1530HCLS/SR1530HCLSR (SAS) Fan System fan blower 1 System fan blower 2 PCI cooling fan (SR1530CL only) Table 14. Cooling Zones Cooling Zone CPU1 CPU2 PCI Greatest Cooling Influence Primary cooling for CPU1 and the system memory Primary cooling for hard HDD1, CPU2, the...air pressure. Revision 2.2 15 Intel order number D71005-005 The baffle is mounted into three stand-offs with one end fitting under the back edge of the hard drive bay. Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Cooling Sub-System A B AF001648 Figure 11....
Product Specification
Page 32
... Green Green State N/A Solid on System and the operating system are up . In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. Redundancy loss such as power-supply or fan. Temperature and voltage 24 Revision 2.2 Intel order number D71005-005 Front Control Panel Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR The...
... Green Green State N/A Solid on System and the operating system are up . In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. Redundancy loss such as power-supply or fan. Temperature and voltage 24 Revision 2.2 Intel order number D71005-005 Front Control Panel Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR The...
Product Specification
Page 33
... Processor 1 missing Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed) No power good - The Intel® Server Board S5000VCL also provides a header giving access to cool the system not present or failed In non-sparing and non-... stepping mismatch) 5.1.3 Drive Activity LED The drive activity LED on Critical, nonrecoverable Description Non-fatal alarm - Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Front Control Panel Color State Amber Blink Criticality Non-critical Amber Solid on the ...
... Processor 1 missing Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed) No power good - The Intel® Server Board S5000VCL also provides a header giving access to cool the system not present or failed In non-sparing and non-... stepping mismatch) 5.1.3 Drive Activity LED The drive activity LED on Critical, nonrecoverable Description Non-fatal alarm - Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Front Control Panel Color State Amber Blink Criticality Non-critical Amber Solid on the ...
Product Specification
Page 38
... server board information. 8.1 Intel® Server Board S5000VCL Feature Set Table 26. Supported Intel® Server Boards Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR 8. See the technical product specification for the server board for Intel® System Management Software 30 Revision 2.2 Intel order number D71005-005 Supported Intel® Server Boards The systems are mechanically and functionally designed to support the Intel® Server...
... server board information. 8.1 Intel® Server Board S5000VCL Feature Set Table 26. Supported Intel® Server Boards Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR 8. See the technical product specification for the server board for Intel® System Management Software 30 Revision 2.2 Intel order number D71005-005 Supported Intel® Server Boards The systems are mechanically and functionally designed to support the Intel® Server...
Product Specification
Page 51
... Reading configuration data from memory (SPD on DIMM) Detecting presence of memory Programming timing parameters in the memory controller Configuring memory parameters in the memory controller Optimizing memory controller settings Initializing memory, such as ECC init Testing memory Enumerating PCI busses Allocating... controller Disabling the console controller Enabling the console controller Revision 2.2 43 Intel order number D71005-005 Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix B: POST Code Diagnostic LED Decoder Table 30.
... Reading configuration data from memory (SPD on DIMM) Detecting presence of memory Programming timing parameters in the memory controller Configuring memory parameters in the memory controller Optimizing memory controller settings Initializing memory, such as ECC init Testing memory Enumerating PCI busses Allocating... controller Disabling the console controller Enabling the console controller Revision 2.2 43 Intel order number D71005-005 Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix B: POST Code Diagnostic LED Decoder Table 30.
Product Specification
Page 52
Appendix B: POST Code Diagnostic LED Decoder Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Diagnostic LED Decoder Checkpoint G=Green, R=Red, A=Amber MSB LSB Keyboard (PS2 or USB) 0x90h R OFF OFF R 0x91h R OFF OFF A 0x92h R ... device selection Trying boot device selection Trying boot device selection Trying boot device selection Trying boot device selection Started dispatching early initialization modules (PEIM) Initial memory found, configured, and installed correctly 44 Revision 2.2 Intel order number D71005-005
Appendix B: POST Code Diagnostic LED Decoder Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Diagnostic LED Decoder Checkpoint G=Green, R=Red, A=Amber MSB LSB Keyboard (PS2 or USB) 0x90h R OFF OFF R 0x91h R OFF OFF A 0x92h R ... device selection Trying boot device selection Trying boot device selection Trying boot device selection Trying boot device selection Started dispatching early initialization modules (PEIM) Initial memory found, configured, and installed correctly 44 Revision 2.2 Intel order number D71005-005
Product Specification
Page 54
...offset Supported? Codes that are common across all Intel® Server Boards and systems that use the Intel® 5000 Chipset are not sounded continuously. POST Error Beep Codes POST Progress Code Description System halted because a fatal error related to inform users...is followed by a sequence of failure conditions. Beeps Error Message 3 Memory error 6 BIOS rolling back error Table 31. Appendix C: POST Error Beep Codes Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix C: POST Error Beep Codes The ...
...offset Supported? Codes that are common across all Intel® Server Boards and systems that use the Intel® 5000 Chipset are not sounded continuously. POST Error Beep Codes POST Progress Code Description System halted because a fatal error related to inform users...is followed by a sequence of failure conditions. Beeps Error Message 3 Memory error 6 BIOS rolling back error Table 31. Appendix C: POST Error Beep Codes Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS and SR1530CLR/SR1530HCLR/SR1530HCLSR Appendix C: POST Error Beep Codes The ...