... Thermal: • Enterprise: 40 CFU, 35°C, 1500 m • Telco: 40 CFU, 40°C, 1800 m 4 Intel® Server Compute Blade SBX44: Installation and User's Guide Blade server off : -40° to 60°C (-40° to 7000 ft) - Microprocessor: Size: Environment: Supports up to 4 ...functions: • Four Gigabit Ethernet controllers • ATI* Radeon 7000 video controller • Light Path Diagnostics* • Local service processor • IDE hard disk drive controller • RS-485 interface for communication with keyboard, mouse, diskette drive, and CD-ROM ...
... Thermal: • Enterprise: 40 CFU, 35°C, 1500 m • Telco: 40 CFU, 40°C, 1800 m 4 Intel® Server Compute Blade SBX44: Installation and User's Guide Blade server off : -40° to 60°C (-40° to 7000 ft) - Microprocessor: Size: Environment: Supports up to 4 ...functions: • Four Gigabit Ethernet controllers • ATI* Radeon 7000 video controller • Light Path Diagnostics* • Local service processor • IDE hard disk drive controller • RS-485 interface for communication with keyboard, mouse, diskette drive, and CD-ROM ...
User Guide
Page 17
What your Intel® Server Compute Blade SBX44 offers The design of your blade server supports up to 16 GB of advancements in which damage could occur. • Caution: These statements indicate situations that can be potentially ... be potentially lethal or extremely hazardous to build powerful, scalable, reliable Intel® processor-based servers. Notices and statements used in this book The caution and danger statements used in the multilingual Safety Information book provided on the blade server control panel is placed just before the instruction or situation in memory...
What your Intel® Server Compute Blade SBX44 offers The design of your blade server supports up to 16 GB of advancements in which damage could occur. • Caution: These statements indicate situations that can be potentially ... be potentially lethal or extremely hazardous to build powerful, scalable, reliable Intel® processor-based servers. Notices and statements used in this book The caution and danger statements used in the multilingual Safety Information book provided on the blade server control panel is placed just before the instruction or situation in memory...
User Guide
Page 18
...serviceability features Three of the data stored on LAN capability 6 Intel® Server Compute Blade SBX44: Installation and User's Guide The controllers support Wake on LAN® technology. • I/O expansion Your blade server comes with two connectors on the system board for I/O ... (PFA) alerts • Service processor that your blade server supports: • Advanced Configuration and Power Interface (ACPI) • Automatic server restart • Built-in server design are reliability, availability, and serviceability (RAS). that your blade server is a list of some of ...
...serviceability features Three of the data stored on LAN capability 6 Intel® Server Compute Blade SBX44: Installation and User's Guide The controllers support Wake on LAN® technology. • I/O expansion Your blade server comes with two connectors on the system board for I/O ... (PFA) alerts • Service processor that your blade server supports: • Advanced Configuration and Power Interface (ACPI) • Automatic server restart • Built-in server design are reliability, availability, and serviceability (RAS). that your blade server is a list of some of ...
User Guide
Page 21
... Error LED (Amber) B Processor Error LEDs C DIMM Error LEDs D Light Path Diagnostics* Button E Light Path Diagnostics* LED E D TP00447 Introduction 9 The LEDs will remain lit for user-installable options. You might need to remove the blade server from the system chassis, open ...the cover, and press the Light Path Diagnostics* button to this illustration when solving problems with the blade server. A B C D E DIMM 1 DIMM 2 DIMM 3 DIMM 4 DIMM 5 DIMM 6 DIMM 7 DIMM 8 A CPU 3 B CPU 4 C Flex Cable Connector D Flex Cable Connector E Flex Cable Connector F ...
... Error LED (Amber) B Processor Error LEDs C DIMM Error LEDs D Light Path Diagnostics* Button E Light Path Diagnostics* LED E D TP00447 Introduction 9 The LEDs will remain lit for user-installable options. You might need to remove the blade server from the system chassis, open ...the cover, and press the Light Path Diagnostics* button to this illustration when solving problems with the blade server. A B C D E DIMM 1 DIMM 2 DIMM 3 DIMM 4 DIMM 5 DIMM 6 DIMM 7 DIMM 8 A CPU 3 B CPU 4 C Flex Cable Connector D Flex Cable Connector E Flex Cable Connector F ...
User Guide
Page 22
... Switch description Not used Password clear CMOS clear Reserved BMC force update 10 Intel® Server Compute Blade SBX44: Installation and User's Guide Table 2. BCE S A DJ R Q P O I M N H K L Switches F G A NMI Error LED B BMC Error LED C Temp Error LED D I/O Board Error LED E Light Path Diagnostics* LED F Processor Board Error LED G Board Error LED H Secondary IDE Error LED I Primary IDE...
... Switch description Not used Password clear CMOS clear Reserved BMC force update 10 Intel® Server Compute Blade SBX44: Installation and User's Guide Table 2. BCE S A DJ R Q P O I M N H K L Switches F G A NMI Error LED B BMC Error LED C Temp Error LED D I/O Board Error LED E Light Path Diagnostics* LED F Processor Board Error LED G Board Error LED H Secondary IDE Error LED I Primary IDE...
User Guide
Page 25
...so). • You can turn on the blade server remotely by means of the service processor in any of a blade server will not allow that blade server to be turned off the blade server, and what the controls and indicators mean. If the blade server was previously turned on and the operating system ...describes the power features, how to turn on and turn on the blade server. Turning on the blade server After you turn off the blade server, it from the service processor, such as a remote request to AC power, the blade server can start in the chassis management module. • If your ...
...so). • You can turn on the blade server remotely by means of the service processor in any of a blade server will not allow that blade server to be turned off the blade server, and what the controls and indicators mean. If the blade server was previously turned on and the operating system ...describes the power features, how to turn on and turn on the blade server. Turning on the blade server After you turn off the blade server, it from the service processor, such as a remote request to AC power, the blade server can start in the chassis management module. • If your ...
User Guide
Page 27
... request is being processed, then is hard-disk-drive or network activity. Blade server power, controls, and indicators 15 Power-on also. The service processor on the blade server is lit, it indicates that there is steady when the ownership of the blade server in this blade server to recognize the CD-ROM drive, diskette drive, and USB port...
... request is being processed, then is hard-disk-drive or network activity. Blade server power, controls, and indicators 15 Power-on also. The service processor on the blade server is lit, it indicates that there is steady when the ownership of the blade server in this blade server to recognize the CD-ROM drive, diskette drive, and USB port...
User Guide
Page 39
... be installed in order, starting with processor 1 and proceeding with processor 2, 3, and 4, based on the system board for microprocessor installation. Microprocessor installation order Configuration Single microprocessor ...CPU4 Locate the appropriate microprocessor socket(s) on whether the system has a single, dual or quad processor configuration. Installing options 27 Prepare for installing an additional microprocessor (see the following figure). A three-processor configuration is NOT supported. Table 3. 5. Remove the air baffle and set aside for reinstallation....
... be installed in order, starting with processor 1 and proceeding with processor 2, 3, and 4, based on the system board for microprocessor installation. Microprocessor installation order Configuration Single microprocessor ...CPU4 Locate the appropriate microprocessor socket(s) on whether the system has a single, dual or quad processor configuration. Installing options 27 Prepare for installing an additional microprocessor (see the following figure). A three-processor configuration is NOT supported. Table 3. 5. Remove the air baffle and set aside for reinstallation....