Product Guide
Page 7
... how to start up and shut down the server. • Chapter 3 describes the Intel® Server System S7000FC4UR Deployment Toolkit CD. • Chapter 4 provides instructions for using the Intel® Server System S7000FC4UR. This document provides a brief overview of the...BIOS Setup screens, how to perform BIOS and firmware updates, and how to perform these tasks. • Chapter 6 provides instructions for system technicians who are shipped with the server system or that require a certified service technician. In this chapter, you will find a list of the Server System S7000FC4UR...
... how to start up and shut down the server. • Chapter 3 describes the Intel® Server System S7000FC4UR Deployment Toolkit CD. • Chapter 4 provides instructions for using the Intel® Server System S7000FC4UR. This document provides a brief overview of the...BIOS Setup screens, how to perform BIOS and firmware updates, and how to perform these tasks. • Chapter 6 provides instructions for system technicians who are shipped with the server system or that require a certified service technician. In this chapter, you will find a list of the Server System S7000FC4UR...
Product Guide
Page 8
... For drivers For firmware and BIOS updates For software to manage your Intel® server Use this Document or Software Intel® Server System S7000FC4UR Technical Product Specification Intel® Server System S7000FC4UR Quick Start User's Guide in the search field at the left side of drivers available) Operating System Driver (for operating system drivers) Firmware Update Intel System Management Software viii Intel® Server System S7000FC4UR Product Guide
... For drivers For firmware and BIOS updates For software to manage your Intel® server Use this Document or Software Intel® Server System S7000FC4UR Technical Product Specification Intel® Server System S7000FC4UR Quick Start User's Guide in the search field at the left side of drivers available) Operating System Driver (for operating system drivers) Firmware Update Intel System Management Software viii Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 10
...Server 37 Chapter 3: Intel® Server Deployment Toolkit 39 Chapter 4: Server Utilities 41 Using the BIOS Setup Utility 41 Navigating the BIOS Setup Utility 41 System Configuration Reset 43 Rolling BIOS 45 Booting from Backup Image 45 Console Redirection 46 Serial Configuration Settings 46 Keystroke Mappings 47 Limitations 48 Interface to Server... a Hot-swap PCI Card, Operating System Interface 69 Removing a Hot-swap PCI Card, Hardware Interface 71 Installing a Hot-swap PCI Card 72 Removing a Non-hot-swap PCI Card 74 x Intel® Server System S7000FC4UR Product Guide
...Server 37 Chapter 3: Intel® Server Deployment Toolkit 39 Chapter 4: Server Utilities 41 Using the BIOS Setup Utility 41 Navigating the BIOS Setup Utility 41 System Configuration Reset 43 Rolling BIOS 45 Booting from Backup Image 45 Console Redirection 46 Serial Configuration Settings 46 Keystroke Mappings 47 Limitations 48 Interface to Server... a Hot-swap PCI Card, Operating System Interface 69 Removing a Hot-swap PCI Card, Hardware Interface 71 Installing a Hot-swap PCI Card 72 Removing a Non-hot-swap PCI Card 74 x Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 41
... components • Processor sockets • Four memory board connectors • Video components • Trusted Platform Module • BIOS Flash components Intel® Server System S7000FC4UR Product Guide 23 CPU 4 CPU 3 CPU 2 CPU 1 Memory Riser A FBD DDR2 533/667 Memory Riser B FBD ... 5 A-Video #2 A-Video #1 Video (ATI RN50) Rear Video Connector Video Memory (32 Mb, 16Mx16) Rear Rear Internal USB USB USB Header Internal 4 SATA SATA Ports FMLs, IPMB, SMBusses DVO, DDC Intel Remote Management Module GCM3 PHY MII (General 10/100 LAN RJ45 Communications Module #3) RMM2/ASMI...
... components • Processor sockets • Four memory board connectors • Video components • Trusted Platform Module • BIOS Flash components Intel® Server System S7000FC4UR Product Guide 23 CPU 4 CPU 3 CPU 2 CPU 1 Memory Riser A FBD DDR2 533/667 Memory Riser B FBD ... 5 A-Video #2 A-Video #1 Video (ATI RN50) Rear Video Connector Video Memory (32 Mb, 16Mx16) Rear Rear Internal USB USB USB Header Internal 4 SATA SATA Ports FMLs, IPMB, SMBusses DVO, DDC Intel Remote Management Module GCM3 PHY MII (General 10/100 LAN RJ45 Communications Module #3) RMM2/ASMI...
Product Guide
Page 44
AC D B EF AF002276 Label A Name Rolling BIOS B Password disable or clear C Clear CMOS / NVRAM D BMC force update E BMC flash write protect Location J3D1 J3C2 J3C3 J5C1 J6D1 Default Empty Stuff Stuff Empty ... 2 - 3 = Password disabled / cleared 1 - 2 = Normal 2 - 3 = Forced CMOS / NVRAM clear 1 - 2 = Disable BMC force update 2 - 3 = Enable BMC force update 1 - 2 = Disable flash write protect 2 - 3 = Enable flash write protect 26 Intel® Server System S7000FC4UR Product Guide
AC D B EF AF002276 Label A Name Rolling BIOS B Password disable or clear C Clear CMOS / NVRAM D BMC force update E BMC flash write protect Location J3D1 J3C2 J3C3 J5C1 J6D1 Default Empty Stuff Stuff Empty ... 2 - 3 = Password disabled / cleared 1 - 2 = Normal 2 - 3 = Forced CMOS / NVRAM clear 1 - 2 = Disable BMC force update 2 - 3 = Enable BMC force update 1 - 2 = Disable flash write protect 2 - 3 = Enable flash write protect 26 Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 48
... option to disable Gbit port A and / or port B in the BIOS. A B C D Item A Description Intel® RMM2 NIC AF002241 Item C Description Dual gigabit LAN Ethernet ports 30 Intel® Server System S7000FC4UR Product Guide The Intel® Remote Management Module 2 (Intel® RMM2) and RMM2 NIC plug into the server, with a dedicated maintenance Ethernet port, and additional dual-gigabit Ethernet...
... option to disable Gbit port A and / or port B in the BIOS. A B C D Item A Description Intel® RMM2 NIC AF002241 Item C Description Dual gigabit LAN Ethernet ports 30 Intel® Server System S7000FC4UR Product Guide The Intel® Remote Management Module 2 (Intel® RMM2) and RMM2 NIC plug into the server, with a dedicated maintenance Ethernet port, and additional dual-gigabit Ethernet...
Product Guide
Page 53
... 7 Figure 21. Server and Platform Management The server management embedded technologies include: • Board instrumentation • Sensors • Interconnects • Server management controllers • Firmware algorithms • System BIOS The platform management system includes: • Baseboard management controller (BMC) • Watchdog timer • Messaging support, including command bridging and user/session support Intel® Server System S7000FC4UR Product Guide 35
... 7 Figure 21. Server and Platform Management The server management embedded technologies include: • Board instrumentation • Sensors • Interconnects • Server management controllers • Firmware algorithms • System BIOS The platform management system includes: • Baseboard management controller (BMC) • Watchdog timer • Messaging support, including command bridging and user/session support Intel® Server System S7000FC4UR Product Guide 35
Product Guide
Page 54
• Chassis device functionality, including power/reset control and BIOS boot flag support • Alert processing device, including platform event trap (PET) and Simple Network Management Protocol (SNMP) alerts via LAN interfaces • Platform ...-over-LAN protocol (RMCP, RMCP+) • Serial-over-LAN (SOL) • Chassis intrusion detection and chassis intrusion cable presence detection • Support for the Intel® Remote Management Module 2 • Platform environment control interface (PECI) thermal management support 36 Intel® Server System S7000FC4UR Product Guide
• Chassis device functionality, including power/reset control and BIOS boot flag support • Alert processing device, including platform event trap (PET) and Simple Network Management Protocol (SNMP) alerts via LAN interfaces • Platform ...-over-LAN protocol (RMCP, RMCP+) • Serial-over-LAN (SOL) • Chassis intrusion detection and chassis intrusion cable presence detection • Support for the Intel® Remote Management Module 2 • Platform environment control interface (PECI) thermal management support 36 Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 59
... set of which contains information or links to configure the system and view and change device settings and view environmental information for a link to pages containing specific configuration settings. 4 Server Utilities Using the BIOS Setup Utility The BIOS Setup Utility is a text-based utility that allows you...example, colors, some keys or key sequences, and mouse support may limit some functionality due to access the Systems Options Menu. Navigating the BIOS Setup Utility The BIOS Setup Utility screens are divided into functional areas: • The title bar is at the top of ...
... set of which contains information or links to configure the system and view and change device settings and view environmental information for a link to pages containing specific configuration settings. 4 Server Utilities Using the BIOS Setup Utility The BIOS Setup Utility is a text-based utility that allows you...example, colors, some keys or key sequences, and mouse support may limit some functionality due to access the Systems Options Menu. Navigating the BIOS Setup Utility The BIOS Setup Utility screens are divided into functional areas: • The title bar is at the top of ...
Product Guide
Page 61
...BIOS Setup Utility Exit menu, select "Load Default Values". • Use the main board CMOS/NVRAM Clear jumper (J3C3). - System Configuration Reset You can configure. Move the NVRAM Clear jumper to clear NVRAM. If a value cannot be changeable. Power down the system but do not remove the AC power cords. - Note: Intel® Server System S7000FC4UR... does not support any existing values. Intel® Server System S7000FC4UR Product Guide 43 Key Table 5....
...BIOS Setup Utility Exit menu, select "Load Default Values". • Use the main board CMOS/NVRAM Clear jumper (J3C3). - System Configuration Reset You can configure. Move the NVRAM Clear jumper to clear NVRAM. If a value cannot be changeable. Power down the system but do not remove the AC power cords. - Note: Intel® Server System S7000FC4UR... does not support any existing values. Intel® Server System S7000FC4UR Product Guide 43 Key Table 5....
Product Guide
Page 62
AC D B EF Label A Name Rolling BIOS B Password disable or clear C Clear CMOS / NVRAM D BMC force update E BMC flash write protect F Circuit breaker AF002276 Location J3D1 J3C2 J3C3 J5C1 J6D1 J6F1 Default ... / NVRAM clear 1 - 2 = Disable BMC force update 2 - 3 = Enable BMC force update 1 - 2 = Disable flash write protect 2 - 3 = Enable flash write protect 1 - 2 = 20A/110V (USA) 2 - 3 = 15A/100V (Japan) 44 Intel® Server System S7000FC4UR Product Guide
AC D B EF Label A Name Rolling BIOS B Password disable or clear C Clear CMOS / NVRAM D BMC force update E BMC flash write protect F Circuit breaker AF002276 Location J3D1 J3C2 J3C3 J5C1 J6D1 J6F1 Default ... / NVRAM clear 1 - 2 = Disable BMC force update 2 - 3 = Enable BMC force update 1 - 2 = Disable flash write protect 2 - 3 = Enable flash write protect 1 - 2 = 20A/110V (USA) 2 - 3 = 15A/100V (Japan) 44 Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 63
... the backup image: 1. The Intel® Server System S7000FC4UR supports two physical 4 MB flash parts that holds the BIOS image used to boot the system is corrupted or non-functional, perform a BIOS update to the new BIOS. The user reset the system and was not able to boot to overwrite this : 1. Boots the system with the old BIOS image. - The flash part...
... the backup image: 1. The Intel® Server System S7000FC4UR supports two physical 4 MB flash parts that holds the BIOS image used to boot the system is corrupted or non-functional, perform a BIOS update to the new BIOS. The user reset the system and was not able to boot to overwrite this : 1. Boots the system with the old BIOS image. - The flash part...
Product Guide
Page 64
...null modem cable, the modem needs to command state (Example: AT&D1). Keyboard inputs from a remote console. 5. Console Redirection The BIOS supports keyboard and video redirection through console redirection. An EMP option utilizing CD should not be set to return to be operated without ...modems from sending video updates to the remote console through a modem instead of the Legacy OS boot (INT 19h). 46 Intel® Server System S7000FC4UR Product Guide Serial Configuration Settings When redirecting through the serial link. Handshaking must be used if a modem is not used ...
...null modem cable, the modem needs to command state (Example: AT&D1). Keyboard inputs from a remote console. 5. Console Redirection The BIOS supports keyboard and video redirection through console redirection. An EMP option utilizing CD should not be set to return to be operated without ...modems from sending video updates to the remote console through a modem instead of the Legacy OS boot (INT 19h). 46 Intel® Server System S7000FC4UR Product Guide Serial Configuration Settings When redirecting through the serial link. Handshaking must be used if a modem is not used ...
Product Guide
Page 65
...UTF8 format with a modem running a communication program, sends keystrokes to the local server. Console Redirection Escape Sequences Escape Sequence RrR Defaults to the BIOS from the remote terminal. Keystroke Mappings During console redirection, the remote terminal, which ... system with the following extensions. Table 6. These are interpreted as plus the character or characters, not as VT100+) 2 = VT100+ 3 = VT-UTF8 Inhibit console redirection Restart console redirection "Soft" inhibit console redirection without serial port or modem reset Intel® Server System S7000FC4UR...
...UTF8 format with a modem running a communication program, sends keystrokes to the local server. Console Redirection Escape Sequences Escape Sequence RrR Defaults to the BIOS from the remote terminal. Keystroke Mappings During console redirection, the remote terminal, which ... system with the following extensions. Table 6. These are interpreted as plus the character or characters, not as VT100+) 2 = VT100+ 3 = VT-UTF8 Inhibit console redirection Restart console redirection "Soft" inhibit console redirection without serial port or modem reset Intel® Server System S7000FC4UR...
Product Guide
Page 66
... Intelligent Platform Management Bus (IPMB) to configure the console/host and server for the name and click "OK". 48 Intel® Server System S7000FC4UR Product Guide Power on the server. 2. Use the arrow keys move to "115.2K". 9. Set the Bit Rate to the Server Management menu. 5. BIOS console redirection is running under Windows*. In this example, the...
... Intelligent Platform Management Bus (IPMB) to configure the console/host and server for the name and click "OK". 48 Intel® Server System S7000FC4UR Product Guide Power on the server. 2. Use the arrow keys move to "115.2K". 9. Set the Bit Rate to the Server Management menu. 5. BIOS console redirection is running under Windows*. In this example, the...
Product Guide
Page 67
...default settings for field replaceable units, such as the processor modules, the server board, drives, and memory. Click "OK" to match that which was configured in BIOS Setup (CTS/RTS is included on the server. The test displays results for the other boxes. The console displays the...match that which was configured on the number of processors and the amount of each test and after the video synchronizes on the Intel® Server System S7000FC4UR Server Deployment Toolkit CD. At the COM1 Properties window, select "115200" in the Bits per second (Baud rate) box to ...
...default settings for field replaceable units, such as the processor modules, the server board, drives, and memory. Click "OK" to match that which was configured in BIOS Setup (CTS/RTS is included on the server. The test displays results for the other boxes. The console displays the...match that which was configured on the number of processors and the amount of each test and after the video synchronizes on the Intel® Server System S7000FC4UR Server Deployment Toolkit CD. At the COM1 Properties window, select "115200" in the Bits per second (Baud rate) box to ...
Product Guide
Page 68
...integrated components, and the chipset. Insert the Intel® Server System S7000FC4UR Server Deployment Toolkit CD into your USB flash drive. 5. Allow the autorun feature to enter the BIOS Setup utility. 7. Comprehensive Test with the number of your Intel® Server System S7000FC4UR to be tested. Boot the system. 6. Choose an appropriate option: - ... (FPU) is identical to the comprehensive test, but it manually by pressing the key. From the BIOS Setup utility, go to the Boot Manager menu and choose "EFI Shell." 50 Intel® Server System S7000FC4UR Product Guide
...integrated components, and the chipset. Insert the Intel® Server System S7000FC4UR Server Deployment Toolkit CD into your USB flash drive. 5. Allow the autorun feature to enter the BIOS Setup utility. 7. Comprehensive Test with the number of your Intel® Server System S7000FC4UR to be tested. Boot the system. 6. Choose an appropriate option: - ... (FPU) is identical to the comprehensive test, but it manually by pressing the key. From the BIOS Setup utility, go to the Boot Manager menu and choose "EFI Shell." 50 Intel® Server System S7000FC4UR Product Guide
Product Guide
Page 69
... • Save and Restore System Configuration (SysConfig) Intel® Server System S7000FC4UR Product Guide 51 Intel® Deployment Assistant The Intel® Deployment Assistant provides a single interface with the latest system software. The latest drivers for later use HTMLlike graphical user interface to identical model servers. System Setup and Configuration Utilities Setup and configuration utilities are : BIOS, ESB2, HSC, LCP, as...
... • Save and Restore System Configuration (SysConfig) Intel® Server System S7000FC4UR Product Guide 51 Intel® Deployment Assistant The Intel® Deployment Assistant provides a single interface with the latest system software. The latest drivers for later use HTMLlike graphical user interface to identical model servers. System Setup and Configuration Utilities Setup and configuration utilities are : BIOS, ESB2, HSC, LCP, as...
Product Guide
Page 70
FWPIAUPD Firmware Load Utility The Firmware Update utility updates these server management controllers: • Baseboard management controller (BMC) • Hot-swap controller (HSC) • LCD control panel (LCP) 52 Intel® Server System S7000FC4UR Product Guide • FWPIAUPD Firmware Load utility • iFlash32 BIOS Load utility • FRUSDR Load utility Available utilities for EFI include: • SELViewer...
FWPIAUPD Firmware Load Utility The Firmware Update utility updates these server management controllers: • Baseboard management controller (BMC) • Hot-swap controller (HSC) • LCD control panel (LCP) 52 Intel® Server System S7000FC4UR Product Guide • FWPIAUPD Firmware Load utility • iFlash32 BIOS Load utility • FRUSDR Load utility Available utilities for EFI include: • SELViewer...
Product Guide
Page 71
...to upgrade the system BIOS. The FRU is an OS-present command-line utility that the server management software monitors. excluding add-in your server; Intel® Server System S7000FC4UR Product Guide 53 FRUSDR Load Utility The FRUSDR Load utility updates and modifies the server management subsystem's product...the baseboard management controller (BMC) • Hot-swap controller (HSC) firmware • Intel® Local Control Panel firmware • Field replaceable units (FRU). With the FRUSDR Load Utility, you upgrade or replace the hardware in cards, hard drives, fans, and RAM.
...to upgrade the system BIOS. The FRU is an OS-present command-line utility that the server management software monitors. excluding add-in your server; Intel® Server System S7000FC4UR Product Guide 53 FRUSDR Load Utility The FRUSDR Load utility updates and modifies the server management subsystem's product...the baseboard management controller (BMC) • Hot-swap controller (HSC) firmware • Intel® Local Control Panel firmware • Field replaceable units (FRU). With the FRUSDR Load Utility, you upgrade or replace the hardware in cards, hard drives, fans, and RAM.