Product Specification
Page 3
...have no liability whatsoever, and Intel® disclaims any features or instructions marked ―reserved‖ or ―undefined‖. Intel® may make changes to meet the intended thermal requirements of others. Intel's own chassis are trademarks or registered trademarks ...of Sale for such products, Intel® assumes no responsibility whatsoever for their published operating or non-operating limits. Intel Corporation cannot be held responsible if components ...
...have no liability whatsoever, and Intel® disclaims any features or instructions marked ―reserved‖ or ―undefined‖. Intel® may make changes to meet the intended thermal requirements of others. Intel's own chassis are trademarks or registered trademarks ...of Sale for such products, Intel® assumes no responsibility whatsoever for their published operating or non-operating limits. Intel Corporation cannot be held responsible if components ...
Product Specification
Page 7
... Code Diagnostic LED Decoder 129 Appendix D: POST Code Errors 133 Appendix E: Supported Intel® Server Chassis 136 Glossary ...137 Reference Documents ...141 Revision 1.0 vii Intel order number G13326-003 Intel® Light Guided Diagnostics 109 9.1 System Status LED (Only for The Intel® Server Board S1200BTL) ...107 8.3 ME Force Update Jumper 107 8.4 BIOS Recovery Jumper 108...
... Code Diagnostic LED Decoder 129 Appendix D: POST Code Errors 133 Appendix E: Supported Intel® Server Chassis 136 Glossary ...137 Reference Documents ...141 Revision 1.0 vii Intel order number G13326-003 Intel® Light Guided Diagnostics 109 9.1 System Status LED (Only for The Intel® Server Board S1200BTL) ...107 8.3 ME Force Update Jumper 107 8.4 BIOS Recovery Jumper 108...
Product Specification
Page 13
...Tables Appendix C - POST Code Diagnostic LED Decoder Appendix D - Supported Intel® Server Chassis Glossary Reference Documents 1.2 Server Board Use Disclaimer Intel Corporation server boards contain a number of high-density VLSI and power delivery components that when... conditions. BIOS User Interface Chapter 7 - Server Board Overview Chapter 3 - Intel Corporation cannot be ordered through its own chassis development and testing that need adequate airflow to determine the amount of these components. EPS and EDS ...
...Tables Appendix C - POST Code Diagnostic LED Decoder Appendix D - Supported Intel® Server Chassis Glossary Reference Documents 1.2 Server Board Use Disclaimer Intel Corporation server boards contain a number of high-density VLSI and power delivery components that when... conditions. BIOS User Interface Chapter 7 - Server Board Overview Chapter 3 - Intel Corporation cannot be ordered through its own chassis development and testing that need adequate airflow to determine the amount of these components. EPS and EDS ...
Product Specification
Page 20
Overview Intel®Server Board S1200BT TPS Description C SATA_KEY D Slot 7, PCI Express* Gen2 x8 (x16 connector) E Ethernet and Dual USB COMBO F Ethernet and Dual USB COMBO G Video port H External Serial port I CPU Power connector J SYS_FAN_2 K DIMM slots L MAIN power connector M TPM connector Description P CPU Fan connector Q Chassis Intrusion R SATA_SGPIO S SYS_FAN_3 T Six 3Gb/s SATA ports U Low profile USB connector V Internal USB W CMOS battery X Front Panel Y HDD LED 2.2.2 Intel® Server Board S1200BTL Mechanical Drawings 8 Revision 1.0 Intel order number G13326-003
Overview Intel®Server Board S1200BT TPS Description C SATA_KEY D Slot 7, PCI Express* Gen2 x8 (x16 connector) E Ethernet and Dual USB COMBO F Ethernet and Dual USB COMBO G Video port H External Serial port I CPU Power connector J SYS_FAN_2 K DIMM slots L MAIN power connector M TPM connector Description P CPU Fan connector Q Chassis Intrusion R SATA_SGPIO S SYS_FAN_3 T Six 3Gb/s SATA ports U Low profile USB connector V Internal USB W CMOS battery X Front Panel Y HDD LED 2.2.2 Intel® Server Board S1200BTL Mechanical Drawings 8 Revision 1.0 Intel order number G13326-003
Product Specification
Page 36
...beep is emitted to Digital Converters Sixteen fan tachometers Eight Pulse Width Modulators (PWM) Chassis intrusion logic 24 Revision 1.0 Intel order number G13326-003 Only on-board USB controllers are initialized by the BMC: 400MHz 32-bit ARM9 ... available USB controllers including add-in this platform: AXXRMS2AF040, AXXRMS2LL040 and AXX4SASMOD. 3.6 Integrated Baseboard Management Controller The Intel® Server Board S1200BTL has the highly integrated single-chip baseboard management controller based on the USB hub and then enables the devices that...
...beep is emitted to Digital Converters Sixteen fan tachometers Eight Pulse Width Modulators (PWM) Chassis intrusion logic 24 Revision 1.0 Intel order number G13326-003 Only on-board USB controllers are initialized by the BMC: 400MHz 32-bit ARM9 ... available USB controllers including add-in this platform: AXXRMS2AF040, AXXRMS2LL040 and AXX4SASMOD. 3.6 Integrated Baseboard Management Controller The Intel® Server Board S1200BTL has the highly integrated single-chip baseboard management controller based on the USB hub and then enables the devices that...
Product Specification
Page 39
... 9-pin internal DH-10 header (J1B1 on S1200BTS). J8A1 on S1200BTL; You can support any standard serial device. Revision 1.0 27 Intel order number G13326-003 Table 7. The Serial B port is ...a fully functional serial port that can use a standard DH-10 to DB9 cable to direct serial A port to support WS-MAN and CIMON. Serial B Header (J1B2 on S1200BTL...; All users disabled 3.6.2 Optional RMM4 Advanced Management Board On the Intel® Server Board S1200BTL provides RMM4 module. Give the customer the option to...
... 9-pin internal DH-10 header (J1B1 on S1200BTS). J8A1 on S1200BTL; You can support any standard serial device. Revision 1.0 27 Intel order number G13326-003 Table 7. The Serial B port is ...a fully functional serial port that can use a standard DH-10 to DB9 cable to direct serial A port to support WS-MAN and CIMON. Serial B Header (J1B2 on S1200BTL...; All users disabled 3.6.2 Optional RMM4 Advanced Management Board On the Intel® Server Board S1200BTL provides RMM4 module. Give the customer the option to...
Product Specification
Page 45
Intel®Server Board S1200BT TPS Platform Management 4.1 Feature Support 4.1.1 IPMI 2.0 Features Baseboard management controller (BMC). IPMI Watchdog timer Messaging support, including command bridging and user/session support Chassis device functionality, including power/reset...61607; ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the watchdog timer functionality. Chassis intrusion detection Basic fan control using IPMI FRU commands. System event log (SEL) device functionality: The...
Intel®Server Board S1200BT TPS Platform Management 4.1 Feature Support 4.1.1 IPMI 2.0 Features Baseboard management controller (BMC). IPMI Watchdog timer Messaging support, including command bridging and user/session support Chassis device functionality, including power/reset...61607; ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the watchdog timer functionality. Chassis intrusion detection Basic fan control using IPMI FRU commands. System event log (SEL) device functionality: The...
Product Specification
Page 46
... this generation servers: Sensor and SEL logging additions / enhancements (e.g. The chassis ID LED is a list of servers. It supports secure lockout of detailed data for later analysis by Intel® engineering. Provisioning and inventory enhancements: o Signed Firmware (improved security...conditions. System GUID storage and retrieval Front panel management: The BMC controls the system status LED and chassis ID LED. additional thermal monitoring capability, better isolation of faults to the FRU level) Embedded platform debug feature which...
... this generation servers: Sensor and SEL logging additions / enhancements (e.g. The chassis ID LED is a list of servers. It supports secure lockout of detailed data for later analysis by Intel® engineering. Provisioning and inventory enhancements: o Signed Firmware (improved security...conditions. System GUID storage and retrieval Front panel management: The BMC controls the system status LED and chassis ID LED. additional thermal monitoring capability, better isolation of faults to the FRU level) Embedded platform debug feature which...
Product Specification
Page 47
...; Intelligent Power Node Manager Support requires PMBus-compliant power supply Revision 1.0 35 Intel order number G13326-003 Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State Retention ARP...
...; Intelligent Power Node Manager Support requires PMBus-compliant power supply Revision 1.0 35 Intel order number G13326-003 Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State Retention ARP...
Product Specification
Page 52
...parameters, users, passwords, etc.) Configuration of alerting (SNMP and SMTP). Display system asset information for the product, board, and chassis. Display of BMC-owned sensors (name, status, current reading, enabled thresholds), including color-code status of sensors. Automatic refresh ...to support these advanced features. if a user does not have privilege to export this inactivity period is not meant to be sent to Intel® for debug purposes. Display of sensor data with a configurable refresh rate. On-line help. ...
...parameters, users, passwords, etc.) Configuration of alerting (SNMP and SMTP). Display system asset information for the product, board, and chassis. Display of BMC-owned sensors (name, status, current reading, enabled thresholds), including color-code status of sensors. Automatic refresh ...to support these advanced features. if a user does not have privilege to export this inactivity period is not meant to be sent to Intel® for debug purposes. Display of sensor data with a configurable refresh rate. On-line help. ...
Product Specification
Page 54
...(Static-OLTT): OLTT control registers are configured by exposing an external interface to management software through which supported chassis (Intel® or Non-Intel) and platform chassis configuration is a program used for a given system configuration, the BMC must have valid temp sensors and .... These policies are configured by System BIOS during POST. Support for the BMC controller to NVRAM for CLTT on . 4.4 Intel® Intelligent Power Node Manager 4.4.1 Overview Power management deals with the DIMM temperature sensors as determined by exploiting subsystem knobs (...
...(Static-OLTT): OLTT control registers are configured by exposing an external interface to management software through which supported chassis (Intel® or Non-Intel) and platform chassis configuration is a program used for a given system configuration, the BMC must have valid temp sensors and .... These policies are configured by System BIOS during POST. Support for the BMC controller to NVRAM for CLTT on . 4.4 Intel® Intelligent Power Node Manager 4.4.1 Overview Power management deals with the DIMM temperature sensors as determined by exploiting subsystem knobs (...
Product Specification
Page 90
System Information Screen (S1200BTL) 78 Revision 1.0 Intel order number G13326-003 To access this screen from the Main screen, select Server Management > System Information. System Information Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision...
System Information Screen (S1200BTL) 78 Revision 1.0 Intel order number G13326-003 To access this screen from the Main screen, select Server Management > System Information. System Information Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag BMC Firmware Revision HSC Firmware Revision ME Firmware Revision...
Product Specification
Page 91
Revision 1.0 79 Intel order number G13326-003 Intel®Server Board S1200BT TPS System Information Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag HSC Firmware Revision ME Firmware Revision UUID Server Management BIOS User Interface Figure 29.System Information Screen (S1200BTS) 6.5.2.15 BMC...
Revision 1.0 79 Intel order number G13326-003 Intel®Server Board S1200BT TPS System Information Board Part Number Board Serial Number System Part Number System Serial Number Chassis Part Number Chassis Serial Number Asset Tag HSC Firmware Revision ME Firmware Revision UUID Server Management BIOS User Interface Figure 29.System Information Screen (S1200BTS) 6.5.2.15 BMC...
Product Specification
Page 102
...headers, and jumpers on the server board. Table 17. Connector/Header Locations and Pin-outs Intel®Server Board S1200BT TPS 7. USB Internal 2 Header PCI-E x16 1 PCI-E x8 3 PCI 32 1 Chassis Intrusion 1 6Gb/s Serial ATA 2 3Gb/s Serial ATA 4 IPMB 1 HSBP 1 Smart ... all connector types available on the board and the corresponding reference designators printed on S1200BTL Connector Quantity Reference Designators Connector Type Power supply 3 CPU 1 Main memory 4 Intel® RMM4 Lite 1 Intel® RMM4 1 Dedicated NIC SAS Module 1 CPU Fan 1 System Fans 4...
...headers, and jumpers on the server board. Table 17. Connector/Header Locations and Pin-outs Intel®Server Board S1200BT TPS 7. USB Internal 2 Header PCI-E x16 1 PCI-E x8 3 PCI 32 1 Chassis Intrusion 1 6Gb/s Serial ATA 2 3Gb/s Serial ATA 4 IPMB 1 HSBP 1 Smart ... all connector types available on the board and the corresponding reference designators printed on S1200BTL Connector Quantity Reference Designators Connector Type Power supply 3 CPU 1 Main memory 4 Intel® RMM4 Lite 1 Intel® RMM4 1 Dedicated NIC SAS Module 1 CPU Fan 1 System Fans 4...
Product Specification
Page 103
Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-outs Table 18. Board Connector Matrix on ...System Fans 3 Battery 1 NIC/Stack 2x USB 2 Video 1 Serial port A 1 Front panel 1 USB Internal 1 Header PCI-E x16 1 PCI-E x8 2 PCI 32 1 Chassis Intrusion 1 3Gb/s Serial ATA 6 SATA RAID key 1 SATA_SGPIO 1 J9G1, J9A1 J5J1 J8H1, J8H2, J8H3, J9H1 J4J1 J2J3, J7J1, J7B1 BT2E1 JA4A1, JA5A1 J6A1 J8A1 J1C2... 17 GND 6 +5 Vdc 18 GND 7 GND 19 GND 8 PWRGD_P S 20 NC 9 5 VSB 21 +5 Vdc 10 +12 Vdc 22 +5 Vdc Revision 1.0 91 Intel order number G13326-003
Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-outs Table 18. Board Connector Matrix on ...System Fans 3 Battery 1 NIC/Stack 2x USB 2 Video 1 Serial port A 1 Front panel 1 USB Internal 1 Header PCI-E x16 1 PCI-E x8 2 PCI 32 1 Chassis Intrusion 1 3Gb/s Serial ATA 6 SATA RAID key 1 SATA_SGPIO 1 J9G1, J9A1 J5J1 J8H1, J8H2, J8H3, J9H1 J4J1 J2J3, J7J1, J7B1 BT2E1 JA4A1, JA5A1 J6A1 J8A1 J1C2... 17 GND 6 +5 Vdc 18 GND 7 GND 19 GND 8 PWRGD_P S 20 NC 9 5 VSB 21 +5 Vdc 10 +12 Vdc 22 +5 Vdc Revision 1.0 91 Intel order number G13326-003
Product Specification
Page 105
... Header Table 25. SGPIO Header Pin-out (J1J3 on S1200BTL and J2J2 on S1200BTS) Revision 1.0 93 Intel order number G13326-003 The following table provides the pin-out for use with Intel® and third-party chassis. Table 26. Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-...22 RXD_2 24 RXD_3 26 TX_CLK 28 RX_CLK 30 PRESENT# Table 23. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1 on S1200BTL or J1C2 on S1200BTS) Pin Signal Name 1 SGPIO_CLOCK 2 SGPIO_LOAD 3 GND 4 SGPIO_DATAOUT0 5 SGPIO_DATAOUT1 Description SGPIO Clock Signal SGPIO Load ...
... Header Table 25. SGPIO Header Pin-out (J1J3 on S1200BTL and J2J2 on S1200BTS) Revision 1.0 93 Intel order number G13326-003 The following table provides the pin-out for use with Intel® and third-party chassis. Table 26. Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-...22 RXD_2 24 RXD_3 26 TX_CLK 28 RX_CLK 30 PRESENT# Table 23. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1 on S1200BTL or J1C2 on S1200BTS) Pin Signal Name 1 SGPIO_CLOCK 2 SGPIO_LOAD 3 GND 4 SGPIO_DATAOUT0 5 SGPIO_DATAOUT1 Description SGPIO Clock Signal SGPIO Load ...
Product Specification
Page 107
...chassis ID button is pressed again with no degraded, non-critical, critical, or non-recoverable conditions exist. The BIOS does not affect the behavior of 10 and migrating to non-redundant systems. Correctable errors over a threshold of the reset button. 7.4.3 System Status Indicator LED The Intel® Server Board S1200BTL...on the front panel. This does not apply to a spare DIMM (memory sparing). If the button is pressed, then the chassis ID LED changes to the system status LED. 2. Non-recoverable temperature threshold asserted. Power fault/Power Control Failure. Non-critical...
...chassis ID button is pressed again with no degraded, non-critical, critical, or non-recoverable conditions exist. The BIOS does not affect the behavior of 10 and migrating to non-redundant systems. Correctable errors over a threshold of the reset button. 7.4.3 System Status Indicator LED The Intel® Server Board S1200BTL...on the front panel. This does not apply to a spare DIMM (memory sparing). If the button is pressed, then the chassis ID LED changes to the system status LED. 2. Non-recoverable temperature threshold asserted. Power fault/Power Control Failure. Non-critical...
Product Specification
Page 112
... P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND NC GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND NC NC GND P2E_CPU_S6_RXN P2E_CPU_S6_RXP GND GND 100 Revision 1.0 Intel order number G13326-003 The following table shows the pin-out for this riser slot. Connector/Header Locations and Pin-outs...
... P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND NC GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND GND P2E_CPU_S6_RXP P2E_CPU_S6_RXN GND NC NC GND P2E_CPU_S6_RXN P2E_CPU_S6_RXP GND GND 100 Revision 1.0 Intel order number G13326-003 The following table shows the pin-out for this riser slot. Connector/Header Locations and Pin-outs...
Product Specification
Page 115
...ground Power supply 12 V FAN_TACH signal is identical and defined in the following table: One 4-pin fan headers are designated as the CPU and chassis. Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-outs Pin # B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30... monitor the fan speed FAN_PWM signal to be used as processor cooling fans: o CPU fan (J5J1 on S1200BTL and J4J1 on S1200BTS) o SYS1 fan (J1J4 on S1200BTL and J7J1 on S1200BTS) o SYS2 fan (J5J2 on S1200BTL and J7B1 on S1200BTS) o SYS3 fan (J7J1 on S1200BTL and J2J1 on S1200BTS) o SYS4 fan (J7B1 for...
...ground Power supply 12 V FAN_TACH signal is identical and defined in the following table: One 4-pin fan headers are designated as the CPU and chassis. Intel®Server Board S1200BT TPS Connector/Header Locations and Pin-outs Pin # B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30... monitor the fan speed FAN_PWM signal to be used as processor cooling fans: o CPU fan (J5J1 on S1200BTL and J4J1 on S1200BTS) o SYS1 fan (J1J4 on S1200BTL and J7J1 on S1200BTS) o SYS2 fan (J5J2 on S1200BTL and J7B1 on S1200BTS) o SYS3 fan (J7J1 on S1200BTL and J2J1 on S1200BTS) o SYS4 fan (J7B1 for...
Product Specification
Page 118
... (covering pins 2 and 3). 4. Power down , after the procedure is followed and AC power is re-applied. Close the server chassis. 5. Close the server chassis. 9. The following procedure outlines the new usage model. 8.1.1 Clearing the CMOS To clear the CMOS, perform the following steps: 1. ...now cleared and can be reset by going into the BIOS setup. 106 Revision 1.0 Intel order number G13326-003 Jumper Blocks Intel®Server Board S1200BT TPS features has changed from previous generation Intel® server boards. Power up the server and wait 10 seconds or until POST...
... (covering pins 2 and 3). 4. Power down , after the procedure is followed and AC power is re-applied. Close the server chassis. 5. Close the server chassis. 9. The following procedure outlines the new usage model. 8.1.1 Clearing the CMOS To clear the CMOS, perform the following steps: 1. ...now cleared and can be reset by going into the BIOS setup. 106 Revision 1.0 Intel order number G13326-003 Jumper Blocks Intel®Server Board S1200BT TPS features has changed from previous generation Intel® server boards. Power up the server and wait 10 seconds or until POST...