... Installing a SAS/SATA 4 Pac HDD option 63 Installing a second microprocessor 76 Thermal grease 80 Installing a memory module 81 © Copyright IBM Corp. 2010 iii Contents Safety vii Chapter 1. The System x3650 M2 Type 7947 server 1 The IBM Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser 3 Related documentation 4 Notices and statements in this document 6 Features and...
... Installing a SAS/SATA 4 Pac HDD option 63 Installing a second microprocessor 76 Thermal grease 80 Installing a memory module 81 © Copyright IBM Corp. 2010 iii Contents Safety vii Chapter 1. The System x3650 M2 Type 7947 server 1 The IBM Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser 3 Related documentation 4 Notices and statements in this document 6 Features and...
User Guide
Page 6
... a ServeRAID SAS controller from the World Wide Web 131 Software service and support 132 Hardware service and support 132 IBM Taiwan product service 132 iv System x3650 M2 Type 7947: Installation and User's Guide Configuring the server 111 Using the Setup utility 112 Starting the Setup utility 112 Setup utility menu choices 113 Passwords 116 Using...
... a ServeRAID SAS controller from the World Wide Web 131 Software service and support 132 Hardware service and support 132 IBM Taiwan product service 132 iv System x3650 M2 Type 7947: Installation and User's Guide Configuring the server 111 Using the Setup utility 112 Starting the Setup utility 112 Setup utility menu choices 113 Passwords 116 Using...
User Guide
Page 10
For example, if a caution statement is labeled with the server or optional device before you install the device. viii System x3650 M2 Type 7947: Installation and User's Guide Important: Each caution and danger statement in this document before you perform the procedures. Read any additional safety information that caution ...
For example, if a caution statement is labeled with the server or optional device before you install the device. viii System x3650 M2 Type 7947: Installation and User's Guide Important: Each caution and danger statement in this document before you perform the procedures. Read any additional safety information that caution ...
User Guide
Page 15
.... Important: This product is 240 V under any distribution fault condition. There are present inside these parts, contact a service technician. This server is suitable for use on an IT power-distribution system whose maximum phase-to Clause 2 of the German Ordinance for use with visual display workplace devices according to -phase voltage is...
.... Important: This product is 240 V under any distribution fault condition. There are present inside these parts, contact a service technician. This server is suitable for use on an IT power-distribution system whose maximum phase-to Clause 2 of the German Ordinance for use with visual display workplace devices according to -phase voltage is...
User Guide
Page 17
... and are measured in the design of technology, best practices, and innovative solutions; Chapter 1. The IBM System x3650 M2 Type 7947 server is a 2-U1-high server that is ideally suited for the future. For more information about the terms of 1.75 inches each...performance and reliability. Each increment is 1.75 inches tall. © Copyright IBM Corp. 2010 1 For information about the IBM client reference program, see "What your IBM® System x3650 M2 Type 7947 server, instructions for installing optional devices, and instructions for information and downloads, and ...
... and are measured in the design of technology, best practices, and innovative solutions; Chapter 1. The IBM System x3650 M2 Type 7947 server is a 2-U1-high server that is ideally suited for the future. For more information about the terms of 1.75 inches each...performance and reliability. Each increment is 1.75 inches tall. © Copyright IBM Corp. 2010 1 For information about the IBM client reference program, see "What your IBM® System x3650 M2 Type 7947 server, instructions for installing optional devices, and instructions for information and downloads, and ...
User Guide
Page 18
... locating firmware and documentation might vary slightly from the IBM Web site. The server might have features that are on the ID label on the server front, above each bay is not included in the server documentation. Product name Machine type Model number Serial number IBM System x3650 M2 server 7947 The model number and serial number are not described...
... locating firmware and documentation might vary slightly from the IBM Web site. The server might have features that are on the ID label on the server front, above each bay is not included in the server documentation. Product name Machine type Model number Serial number IBM System x3650 M2 server 7947 The model number and serial number are not described...
User Guide
Page 19
... the language for your hardware. If a document is enabled, insert the CD into the CD or DVD drive. The System x3650 M2 Type 7947 server 3 Chapter 1. The Documentation Browser starts automatically. For more information, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. See the Rack Installation Instructions document on page 119. You can download an...
... the language for your hardware. If a document is enabled, insert the CD into the CD or DVD drive. The System x3650 M2 Type 7947 server 3 Chapter 1. The Documentation Browser starts automatically. For more information, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. See the Rack Installation Instructions document on page 119. You can download an...
User Guide
Page 20
.... It contains information about the server, including how to set up the server, how to install supported optional devices, and how to view it contains information for service technicians. 4 System x3650 M2 Type 7947: Installation and User's Guide Each... caution and danger statement that appears in Acrobat Reader or xpdf. v Problem Determination and Service Guide This document is in PDF on the IBM...
.... It contains information about the server, including how to set up the server, how to install supported optional devices, and how to view it contains information for service technicians. 4 System x3650 M2 Type 7947: Installation and User's Guide Each... caution and danger statement that appears in Acrobat Reader or xpdf. v Problem Determination and Service Guide This document is in PDF on the IBM...
User Guide
Page 21
... procedure might be included on the IBM Documentation CD. Chapter 1. It contains translated environmental notices. v IBM Linux License Information and Attributions This document is at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp. The System x® and xSeries® Tools Center is an online information center that comes with the server. The System x3650 M2 Type 7947 server 5
... procedure might be included on the IBM Documentation CD. Chapter 1. It contains translated environmental notices. v IBM Linux License Information and Attributions This document is at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp. The System x® and xSeries® Tools Center is an online information center that comes with the server. The System x3650 M2 Type 7947 server 5
User Guide
Page 22
...also in the multilingual Safety Information document, which damage might exceed the average values stated because of computers will operate. 6 System x3650 M2 Type 7947: Installation and User's Guide Depending on the number and type of optional features that are marked in vertical increments of ... sound levels were measured in controlled acoustical environments according to you. A caution statement is placed just before the description of the server. A 1-U-high device is referred to the corresponding statement in your language in this document are reported in use. 2. Power ...
...also in the multilingual Safety Information document, which damage might exceed the average values stated because of computers will operate. 6 System x3650 M2 Type 7947: Installation and User's Guide Depending on the number and type of optional features that are marked in vertical increments of ... sound levels were measured in controlled acoustical environments according to you. A caution statement is placed just before the description of the server. A 1-U-high device is referred to the corresponding statement in your language in this document are reported in use. 2. Power ...
User Guide
Page 23
.../100/1000 Ethernet controller with Wake on LAN support and TCP/IP Offload Engine (TOE) support v Four Ethernet ports (two on system board and two additional ports when the optional IBM Dual-Port 1 Gb Ethernet Daughter Card is installed) v One serial port, shared with SVGA and VGA v 16 MB DDR2 SDRAM video... Btu per hour (194 watts) v Maximum configuration: 2302 Btu per microprocessor v Maximum: 128 GB (when 8 GB DIMMs are installed in hot-swap models only. 2. The System x3650 M2 Type 7947 server 7
.../100/1000 Ethernet controller with Wake on LAN support and TCP/IP Offload Engine (TOE) support v Four Ethernet ports (two on system board and two additional ports when the optional IBM Dual-Port 1 Gb Ethernet Daughter Card is installed) v One serial port, shared with SVGA and VGA v 16 MB DDR2 SDRAM video... Btu per hour (194 watts) v Maximum configuration: 2302 Btu per microprocessor v Maximum: 128 GB (when 8 GB DIMMs are installed in hot-swap models only. 2. The System x3650 M2 Type 7947 server 7
User Guide
Page 24
... redundant cooling. UEFI replaces the basic input/output system (BIOS) and defines a standard interface between the operating system, platform firmware, and external devices. The IMM provides remote server management through industry-standard interfaces: - Remotely accessing the server, using the keyboard and mouse from a remote client 8 System x3650 M2 Type 7947: Installation and User's Guide Features and specifications (continued...
... redundant cooling. UEFI replaces the basic input/output system (BIOS) and defines a standard interface between the operating system, platform firmware, and external devices. The IMM provides remote server management through industry-standard interfaces: - Remotely accessing the server, using the keyboard and mouse from a remote client 8 System x3650 M2 Type 7947: Installation and User's Guide Features and specifications (continued...
User Guide
Page 25
... text report file. v Active Energy Manager The Active Energy Manager solution is an IBM Systems Director extension that are stored on the IBM Documentation CD v IBM Systems Director IBM Systems Director is collected into a file that includes events from a Web browser. Uploading ... the server: - This enables you can use to assist in diagnosing server problems. The diagnostic programs collect the following information about DSA Preboot diagnostics, see the Problem Determination and Service Guide on the integrated USB memory. Chapter 1. The System x3650 M2 Type 7947 server 9
... text report file. v Active Energy Manager The Active Energy Manager solution is an IBM Systems Director extension that are stored on the IBM Documentation CD v IBM Systems Director IBM Systems Director is collected into a file that includes events from a Web browser. Uploading ... the server: - This enables you can use to assist in diagnosing server problems. The diagnostic programs collect the following information about DSA Preboot diagnostics, see the Problem Determination and Service Guide on the integrated USB memory. Chapter 1. The System x3650 M2 Type 7947 server 9
User Guide
Page 26
...pair of DIMMs. v Redundant connection The addition of memory through memory mirroring. Large system-memory capacity The memory bus supports up to 128 GB of DIMMs simultaneously. - v IBM ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD, which support connection...the Gigabit Ethernet controller" on the server, all Ethernet traffic that is associated with two integrated Broadcom Gigabit Ethernet controllers, which you can add, remove, or replace hard disk drives without user intervention. 10 System x3650 M2 Type 7947: Installation and User's Guide Active™...
...pair of DIMMs. v Redundant connection The addition of memory through memory mirroring. Large system-memory capacity The memory bus supports up to 128 GB of DIMMs simultaneously. - v IBM ServerGuide Setup and Installation CD The ServerGuide Setup and Installation CD, which support connection...the Gigabit Ethernet controller" on the server, all Ethernet traffic that is associated with two integrated Broadcom Gigabit Ethernet controllers, which you can add, remove, or replace hard disk drives without user intervention. 10 System x3650 M2 Type 7947: Installation and User's Guide Active™...
User Guide
Page 27
...See the operating-system documentation for a typical configuration. The System x3650 M2 Type 7947 server 11 The addition of this document, the Linux operating system does not support TOE. The IMM also provides system monitoring, event recording, and dial-out alert capability. When an operating system that offloads ... LED panels v Integrated management module (service processor) v Memory mirroring Chapter 1. Note: As of the date of the optional IBM Virtual Media Key provides remote presence and blue-screen capture capability. Note: If the maximum load on most connectors v Chipkill memory...
...See the operating-system documentation for a typical configuration. The System x3650 M2 Type 7947 server 11 The addition of this document, the Linux operating system does not support TOE. The IMM also provides system monitoring, event recording, and dial-out alert capability. When an operating system that offloads ... LED panels v Integrated management module (service processor) v Memory mirroring Chapter 1. Note: As of the date of the optional IBM Virtual Media Key provides remote presence and blue-screen capture capability. Note: If the maximum load on most connectors v Chipkill memory...
User Guide
Page 29
The System x3650 M2 Type 7947 server 13 The UpdateXpress System Pack Installer The UpdateXpress System Pack Installer detects supported and installed device drivers and firmware in the server and installs available updates. For additional information and to download the UpdateXpress System Pack Installer, go to the System x and BladeCenter Tools Center at http://www.ibm.com/systems/management/, which presents an overview...
The System x3650 M2 Type 7947 server 13 The UpdateXpress System Pack Installer The UpdateXpress System Pack Installer detects supported and installed device drivers and firmware in the server and installs available updates. For additional information and to download the UpdateXpress System Pack Installer, go to the System x and BladeCenter Tools Center at http://www.ibm.com/systems/management/, which presents an overview...
User Guide
Page 30
... from the rack. When the LED is flashing rapidly (three flashes per second), it indicates that the drive is in use . 14 System x3650 M2 Type 7947: Installation and User's Guide Front view The following illustration shows the controls, connectors, and hard disk drive bays on the front of the... lit, it indicates that the CD-RW/DVD drive is being rebuilt as USB mouse, keyboard, or other USB device, to release the server from the CD-RW/DVD drive. Operator information panel: This panel contains controls, light-emitting diodes (LEDs), and connectors. Hard disk drive status...
... from the rack. When the LED is flashing rapidly (three flashes per second), it indicates that the drive is in use . 14 System x3650 M2 Type 7947: Installation and User's Guide Front view The following illustration shows the controls, connectors, and hard disk drive bays on the front of the... lit, it indicates that the CD-RW/DVD drive is being rebuilt as USB mouse, keyboard, or other USB device, to release the server from the CD-RW/DVD drive. Operator information panel: This panel contains controls, light-emitting diodes (LEDs), and connectors. Hard disk drive status...
User Guide
Page 31
... illustration shows the controls and LEDs on the Chapter 1. To wake the server, press the power-control button or use IBM Systems Director to turn off and is also lit to visually locate the server among other servers. For information about logging on to the IMM Web interface, see "Logging...is on . Light path diagnostics panel The light path diagnostics panel is lit, it indicates that a noncritical event has occurred. The System x3650 M2 Type 7947 server 15 You can press the power-control button to light this latch to the left . You can use the IMM Web interface. ...
... illustration shows the controls and LEDs on the Chapter 1. To wake the server, press the power-control button or use IBM Systems Director to turn off and is also lit to visually locate the server among other servers. For information about logging on to the IMM Web interface, see "Logging...is on . Light path diagnostics panel The light path diagnostics panel is lit, it indicates that a noncritical event has occurred. The System x3650 M2 Type 7947 server 15 You can press the power-control button to light this latch to the left . You can use the IMM Web interface. ...
User Guide
Page 32
...that you are aware of the light path diagnostics panel. Do not run the power-on the IBM Documentation CD. 16 System x3650 M2 Type 7947: Installation and User's Guide By placing the system-error LED indicator in the lower-right corner of the last failure but will not take immediate ...press the button. You might have to use a pen or the end of a straightened paper clip to reset the server and run the server for an extended period of the server. 2. Notes: 1. For more information about light path diagnostics, see the Problem Determination and Service Guide on self-test ...
...that you are aware of the light path diagnostics panel. Do not run the power-on the IBM Documentation CD. 16 System x3650 M2 Type 7947: Installation and User's Guide By placing the system-error LED indicator in the lower-right corner of the last failure but will not take immediate ...press the button. You might have to use a pen or the end of a straightened paper clip to reset the server and run the server for an extended period of the server. 2. Notes: 1. For more information about light path diagnostics, see the Problem Determination and Service Guide on self-test ...
User Guide
Page 33
...(IMM). This connector is an active link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for systems-management information control. Chapter 1. The System x3650 M2 Type 7947 server 17 Serial connector: Connect a 9-pin serial device to this connector. The video connectors on the front and ...rear of the server can take control of the shared serial port to perform text console redirection and to the ...
...(IMM). This connector is an active link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for systems-management information control. Chapter 1. The System x3650 M2 Type 7947 server 17 Serial connector: Connect a 9-pin serial device to this connector. The video connectors on the front and ...rear of the server can take control of the shared serial port to perform text console redirection and to the ...