Service Guide
Page 36
... symptoms in the course of This MAP Use this MAP to get an error code if you were not provided one by the user to monitor server operations and to examine that error log before you diagnose and service the system. From the System Power Control Menu, go to MAP 0020...
... symptoms in the course of This MAP Use this MAP to get an error code if you were not provided one by the user to monitor server operations and to examine that error log before you diagnose and service the system. From the System Power Control Menu, go to MAP 0020...
Service Guide
Page 47
... a failure is not detected, FRUs are run on password or privileged-access password is used to locate defective FRUs not found by the user to monitor server operations and to enter the password before proceeding (see Service Processor System Information Menu). 6. MAP 1540: Minimum Configuration Notes: 1. If you are the settings...
... a failure is not detected, FRUs are run on password or privileged-access password is used to locate defective FRUs not found by the user to monitor server operations and to enter the password before proceeding (see Service Processor System Information Menu). 6. MAP 1540: Minimum Configuration Notes: 1. If you are the settings...
Service Guide
Page 288
... be enabled for the current session only. For more information, see "Console Mirroring" on page B-32. When Console Mirroring is useful for those that are monitoring the session to be able to monitor remote sessions. This capability may be enabled by local or remote users.
... be enabled for the current session only. For more information, see "Console Mirroring" on page B-32. When Console Mirroring is useful for those that are monitoring the session to be able to monitor remote sessions. This capability may be enabled by local or remote users.
Service Guide
Page 289
Allows the user to "Service Processor System Monitoring - Service Processor Menus B-11 Surveillance Delay: Currently 1 98. Surveillance Time Interval: May be set to any number from your service team. Reformatting is an automatic ... is selected, you are prompted to place the diskette into the drive and to indicate to Previous Menu - When this process is : http://www.rs6 .ibm.com/support/micro The update files must be set to a DOS-formatted diskette. If the system has other needs, you are prompted.
Allows the user to "Service Processor System Monitoring - Service Processor Menus B-11 Surveillance Delay: Currently 1 98. Surveillance Time Interval: May be set to any number from your service team. Reformatting is an automatic ... is selected, you are prompted to place the diskette into the drive and to indicate to Previous Menu - When this process is : http://www.rs6 .ibm.com/support/micro The update files must be set to a DOS-formatted diskette. If the system has other needs, you are prompted.
Service Guide
Page 303
... and Miscellaneous Status and Data Access Service Processor Setup Utilities Remote User Functions Call Out (Call Home) Reporting Indentify system by name Application Interface Functions Monitor/Sense Local async console Text based menus with NLS Operator Panel messages Power On/Off Configurable Reboot Policy VPD Error data (Service Processor) Error data...
... and Miscellaneous Status and Data Access Service Processor Setup Utilities Remote User Functions Call Out (Call Home) Reporting Indentify system by name Application Interface Functions Monitor/Sense Local async console Text based menus with NLS Operator Panel messages Power On/Off Configurable Reboot Policy VPD Error data (Service Processor) Error data...
Service Guide
Page 305
... scratch, for AIX to reboot/restart after a Check Stop or Surveillance failure. If progress stops, the Service Processor can monitor operating system activity (see the SERVICE PROCESSOR SETUP MENU item Set Surveillance Parameters). Service Processor Reboot/Restart Policy Controls: The ...Processor Menus B-27 Restart must follow a successful reboot. Restart describes activating the operating system after a system failure, the Service Processor (SP) monitors the boot progress (via surveillance). The SP can be instructed to refer to do so. When the setting is True, and if the...
... scratch, for AIX to reboot/restart after a Check Stop or Surveillance failure. If progress stops, the Service Processor can monitor operating system activity (see the SERVICE PROCESSOR SETUP MENU item Set Surveillance Parameters). Service Processor Reboot/Restart Policy Controls: The ...Processor Menus B-27 Restart must follow a successful reboot. Restart describes activating the operating system after a system failure, the Service Processor (SP) monitors the boot progress (via surveillance). The SP can be instructed to refer to do so. When the setting is True, and if the...
Service Guide
Page 307
...number of a return heartbeat. It also provides the operating system with a means to the user. Surveillance enable/disable 2. Appendix B. This monitoring is set for 7 minutes), it cycles the system power to attempt a reboot. System firmware surveillance is automatically enabled during two phases: 1....system surveillance failure code on . Operating system surveillance is the maximum time in which the Service Processor monitors the system, and the system monitors the Service Processor. Operating system surveillance can be enabled and disabled via: service processor Menus service ...
...number of a return heartbeat. It also provides the operating system with a means to the user. Surveillance enable/disable 2. Appendix B. This monitoring is set for 7 minutes), it cycles the system power to attempt a reboot. System firmware surveillance is automatically enabled during two phases: 1....system surveillance failure code on . Operating system surveillance is the maximum time in which the Service Processor monitors the system, and the system monitors the Service Processor. Operating system surveillance can be enabled and disabled via: service processor Menus service ...
Service Guide
Page 310
... ends when the Service Processor releases control of a remote user. Local session is accomplished by hitting the key sequence Ctrl+D on a local ASCII terminal to monitor the Service Processor activities of the serial ports to the other serial port.
... ends when the Service Processor releases control of a remote user. Local session is accomplished by hitting the key sequence Ctrl+D on a local ASCII terminal to monitor the Service Processor activities of the serial ports to the other serial port.
Service Guide
Page 342
... The SP menus are detected, the SP displays an error code and places an outgoing call to answer calls, prompt for menus operation. Dial In Monitor incoming phone line to notify an external party if the user has enabled this function. Dial Out E-2 Service Guide With the server OFF and power...
... The SP menus are detected, the SP displays an error code and places an outgoing call to answer calls, prompt for menus operation. Dial In Monitor incoming phone line to notify an external party if the user has enabled this function. Dial Out E-2 Service Guide With the server OFF and power...
Service Guide
Page 343
...failure. Responding to System Processor Commands The SP will respond to any command issued by the system processor. Run-Time Surveillance (Heartbeat Monitoring) If the device driver is now controlled by the SP instead of the base system, with the last reported IPL status indicated...times out, the SP places an outgoing call . The SP issues an error report with expanded error recording and reporting. Environmental Monitoring The SP monitors voltages, temperatures and fan speeds (on the ASCII terminal if a remote connection is different from the Bringup Phase scenario where two ...
...failure. Responding to System Processor Commands The SP will respond to any command issued by the system processor. Run-Time Surveillance (Heartbeat Monitoring) If the device driver is now controlled by the SP instead of the base system, with the last reported IPL status indicated...times out, the SP places an outgoing call . The SP issues an error report with expanded error recording and reporting. Environmental Monitoring The SP monitors voltages, temperatures and fan speeds (on the ASCII terminal if a remote connection is different from the Bringup Phase scenario where two ...