Hardware Maintenance Manual - Page 8

... controller 146 Installing the ServeRAID controller 146 Connecting external devices 150 Step 2: Updating BIOS and firmware code 151 Step 3: Configuring ServeRAID controllers 151 Using the ServeRAID Manager program 152 Using Configuration mode 154 Using Information mode 162 Obtaining ServeRAID updates 162 Downloadable files from the World Wide Web . . . 163 ServeRAID device driver order on...
Hardware Maintenance Manual - Page 45

... Ethernet controller manually to another device in the Configuration/Setup Utility program. If the Ethernet Transmit/Receive Activity light is off , there might be a defective connector or cable, or a problem with the hub. - If the label contains an X, the hub has an X port. • Determine if the hub supports auto-negotiation. Ethernet controller troubleshooting chart...
Hardware Maintenance Manual - Page 48

... Link Support Layer (LSL). Type 8665 Models 1RY, 2RY Action: Restart the server. If the problem persists, go to "Starting the diagnostic programs" on page 25 to specify a mode (such as, redundancy) that your hardware configuration matches the software settings. Table 3. If you try to run the diagnostic programs. PCNTNW-NW-086 The driver parameter...
Hardware Maintenance Manual - Page 50

... fails to respond. pnt0-19 Explanation: The SunSoft Solaris driver has been reset due to match the hardware settings. pnt0-15 Explanation: The SunSoft Solaris driver cannot find an Ethernet controller. Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that fails to respond. Cannot allocate...
Hardware Maintenance Manual - Page 58

... start the Configuration/Setup Utility program and change , or delete both the administrator and power-on passwords, and allow a power-on password and administrator password. You can use any changes, the program will prompt you can regain access to the server through one of the password features. 48 Hardware Maintenance Manual: Netfinity 7600 - Type 8665 Models 1RY, 2RY
Hardware Maintenance Manual - Page 86

...the connector. 8. Hazardous voltage, current, and energy levels are no serviceable parts inside any component that has this label attached. There are present inside these parts, contact a service technician. If you suspect a problem with the power supply-installation procedure, review the following label attached. Before you install a power supply in the right-most power supply bay, you...
Hardware Maintenance Manual - Page 99

... can install in the network be automatic or manually controlled, depending on the setup and operating...set any user intervention. This controller provides an interface for redundant Ethernet The IBM...to the primary Ethernet controller. The controller supports half-duplex (HDX) and full-duplex ...the operating system before you must install a device driver to enable the operating system to ...
Hardware Maintenance Manual - Page 106

... Enhancement) - To use as a system-management console, and then install Client Services for Netfinity Manager on your Netfinity server. IBM TCP/IP for OS/2 version 1.2 or later (required for Windows NT system requirements" on page 122. IPX - Netfinity Manager supports only server-to additional installations of hard disk space (space required depends on a system in...
Hardware Maintenance Manual - Page 110

... service on this service to monitor and manage IBM Advanced System Management processors and adapters. Type 8665 Models 1RY, 2RY There is an easy to use resource management and planning tool for network managers and administrators, allowing remote performance monitoring of remote systems that are : • Advanced System Management Support Click Advanced System Management Support to install...
Hardware Maintenance Manual - Page 111

... • System Monitor • System Partition Access (requires System Partition) • Update Connector Manager (available only on client systems using a World Wide Web browser. 8. Install Netfinity Manager. Network communication drivers and the following Netfinity Manager services are available from the IBM selection server. • World Wide Web Enhancement (TCP/IP Required) Click World...
Hardware Maintenance Manual - Page 134

...Manual: Netfinity 7600 - Important: Be sure to install from the appropriate Netfinity Manager directory. This parameter is ignored if the ChangeConfig parameter in which the files were copied. /T: drive Specifies the drive to install to update...response file. Type 8665 Models 1RY, 2RY To create a source directory for a Client Services for a Netfinity Manager installation: 1. Create a ...
Hardware Maintenance Manual - Page 162

... mode. Type 8665 Models 1RY, 2RY The information in this mode is active, a limited set of functions is available from the menu and tool bars. To start the ServeRAID Manager program from the startable IBM ServeRAID Support CD, you can configure your hot-spare drives. See "Using Configuration mode" on specific processes using the ServeRAID...
Hardware Maintenance Manual - Page 175

... settings, and view the controller and PCI information. (See "Using the advanced configuration functions" on page 166 for more information.) • Advanced Functions is loaded before any device drivers you add at installation time, such as follows: • View Controller Status shows the current status of the configuration functions without using the IBM ServeRAID Support...
Hardware Maintenance Manual - Page 242

..." on page 55. 232 Hardware Maintenance Manual: Netfinity 7600 - Ensure all processors are the same stepping level and cache size. 2. If RAID system, refer to help you solve ServeRAID problems when servicing the computer. No ISPR Error Present. 1XXX (Microcode Checksum Error) 1. Type 8665 Models 1RY, 2RY Processor 2 01298103 (Bad update data for processor 1) 1. I/O Legacy Board...
Hardware Maintenance Manual - Page 244

...a.. Check termination of identified channel in the POST (ISPR) error procedures. 234 Hardware Maintenance Manual: Netfinity 7600 - c. and reboot each time to those codes. (EF10 is a default code for jumper locations. 2. If original ISPR code is functioning properly. 3. FFFF or other code not listed 1. Only replace a ServeRAID 3HB Adapter or controller if ind8icated to channel...

IBM 86655RY Reviews

Do you have an experience with the IBM 86655RY that you would like to share?
Earn 750 points for your review!
We have not received any reviews for IBM yet.

Popular IBM 86655RY Search Terms

The following terms are frequently used to search for IBM 86655RY support:

Ask a New Question
Use the box below to post a new question about IBM 86655RY.
Manuals / Documents
Download any of our IBM 86655RY manuals for free!

We have the following 1 documents available for the IBM 86655RY:
  • Hardware Maintenance Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

IBM Manuals

Find free IBM 86655RY - Netfinity 7600 - 8665 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

IBM Reviews

View thousands of IBM 86655RY - Netfinity 7600 - 8665 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete IBM customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed IBM customer service rankings, employee comments and much more from our sister site.

IBM Recalls

Find comprehensive IBM recall information updated hourly on RecallOwl.com.