IBM 8639 - PC Server 325 Support and Manuals
IBM 8639 Videos
Popular IBM 8639 Manual Pages
Hardware Maintenance Manual - Page 3
...Index, service information, error codes, error messages, and configuration information for trained servicers who are familiar with the advanced diagnostic tests and the information in the IBM Personal System/2 Hardware Maintenance Manual (part number 83G8990, form number S52G-9971) and IBM PC Servers Hardware Maintenance Manual (part number 70H0751, form number S30H-2501 to troubleshoot problems...
Hardware Maintenance Manual - Page 9
...can view the IRQ/DMA assignments, memory usage, device drivers, and so on ) Specify the number of passes ...Error Messages
Messages generated by the POST. Multiple messages
Error Message
POST Error Messages
POST Beep Codes
Diagnostic Error Messages
Description
Displayed when POST finds problems with a hardware option.
4 PC Server HMM POST error messages Diagnostic error messages POST beep codes...
Hardware Maintenance Manual - Page 18
... Novell NetWare OS/2 ODI Driver Messages . 52 NDIS 2.01 Driver Messages 54 NDIS 3.0 Driver Messages 57 Packet Driver Messages 59 UNIX Messages 62 Ethernet Device Drivers 66 Ethernet Diagnostics 67 Backing Up the Ethernet Diagnostic Diskette . 67 Starting the Ethernet Diagnostics 67 Ethernet Ports 67 Password 68 Alarm/Wakeup Settings 68
© Copyright IBM Corp. 1996
13 PC...
Hardware Maintenance Manual - Page 19
... the Low-Level Format Program . . 85 Specifications (PC Server 325 - Type 8639) . . . 86 System/Processor Board Replacement . . . . . 87 Symmetric Multiprocessors/Multiprocessing . . . 87 Locations 88 Bezels 88 Controls and Status Indicators 89 Covers 91 Doors 91 Drawer Model Rails 92 Drives 92 Expansion Slots 93 Input/Output Connectors 94 Internal Drive Bays 95 Keylock Assembly...
Hardware Maintenance Manual - Page 35
... is installed that requires the same resource as a hardware device (for example, an expanded memory specification (EMS) device driver that currently do not support sharing of the adapters can also press Esc to two different serial ports).
For information on manually overriding the interrupt, see "Advanced Setup" on page 30. You can bypass the error or start...
Hardware Maintenance Manual - Page 46
... to register with the LSL.
Action: Add more information. Make sure that this driver is seated properly. Type 8639 41 PCNTNW-NW-072 A resource tag is set . Then, restart the server.
Explanation: An error occurred while the driver was not successful.
Action: If you are using . Action: Add or free some memory resources in the...
Hardware Maintenance Manual - Page 47
.... Action: Make sure that the support files that you are using . Action: Restart the server.
If the error recurs, replace the system board.
42 PC Server HMM PCNTNW-NW-076 The polling procedure cannot be read.
Explanation: The driver failed to read process failed. Restart the server. The read a firmware file.
Action: Restart the server...
Hardware Maintenance Manual - Page 58
...the Configuration/Setup utility programs. The IRQ numbers might be assigned automatically, or you might have manually assigned the IRQ number. Verify that the Ethernet jumper on setting the ... Ethernet enable jumper is set to "General Checkout/Diagnostics QAPlus/PRO" on page 34 for the virtual board. If the problem persists, go to the default (enable) position.
Type 8639 53 Or, see "...
Hardware Maintenance Manual - Page 62
...: Modify the IRQ setting in this manual. Explanation: The configuration is already in the setup dialog box. Error messages appear with the...specification from the setup. PC Server 325 - Explanation: The driver cannot locate the Ethernet controller on the hardware or modify the IO Address setting in use by another device. Type 8639 57 Explanation: The specified IO address number is set...
Hardware Maintenance Manual - Page 77
... you do not have the EISA Configuration Utility program or the Configuration/Setup Utility ISA Legacy Resources option follow this procedure.
1. Make sure the adapter configuration diskette is displayed:
Flash Utility
Select one:
Configure Service Processor View Service Processor Configuration Update Service Processor Set Up COM Ports Configure OS Watchdog Timer Exit
Enter F1=Help F3...
Hardware Maintenance Manual - Page 79
... TME 10 NetFinity Version 4.1 documentation for device driver installation instructions. Restart the system to exit from the adapter configuration utility program.
8. Refer to "Device Driver Installation" for information on page 75. Type SETUP
74 PC Server HMM If the operating system is Novell NetWare, go to "OS/2 Device Driver Installation." If the operating system is Windows NT...
Hardware Maintenance Manual - Page 92
... on the processor board to support Symmetric Multiprocessors/Multiprocessing (SMP). The SMP capability also provides a level of the processors should experience a failure. Note If the processor(s) are installed and seated correctly on the new system board. Symmetric Multiprocessors/Multiprocessing
The PC Server 325 Type 8639 has a second upgradeable processor socket on the processor...
Hardware Maintenance Manual - Page 112
...IBM devices not supported by pauses (intervals without sound).
Beeps 1-2-X
4
Description
One beep A pause (or break) Two beeps A pause (or break) Any number of short tones separated by the QAPlus/PRO diagnostics code, refer to help . (For example, 0S/2 Trap)errors, or
Possible software and hardware mismatch problems. (Not repairable by replacing FRUs)
Memory Configuration Problems
Replacing...
Hardware Maintenance Manual - Page 130
... Numbers, U.S.
Related Service Information
Important
The service procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this supplement and the PS/2 Hardware Maintenance Manual (part number 83G8990, form...
Hardware Maintenance Manual - Page 141
... requesting assistance from Service Support and Engineering functions. Are the exact machine type and models 2. Have the same software versions and levels 6. What, when, where, single, or multiple systems? - Have the same Reference/Diagnostics Diskette
(version) 7. Have the same setup for the operation system
control files
Comparing the configuration and software set in use the...