Owner's Manual
Page 3
... and thank you have selected one of our broad line of service. We are designed for buying a Hunter product. Table Of Contents Installation Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Operation Start-Up 16 Reviewing Current Temperature Setting 16 Setting New Temperature 17...
... and thank you have selected one of our broad line of service. We are designed for buying a Hunter product. Table Of Contents Installation Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Operation Start-Up 16 Reviewing Current Temperature Setting 16 Setting New Temperature 17...
Owner's Manual
Page 4
...the entire installation section of your Hunter Thermostat. This Hunter Thermostat will prevent damage to install or operate your thermostat. It does not provide a delay when there are power outages. PROGRAMMING 3You can be restarted. OPERATION 4 Your Hunter Thermostat is normally performed at your Hunter Thermostat. • Remove the mylar ... control multistage heating or cooling systems, 110/220 V systems, or 3 wire zone systems. COMPRESSOR PROTECTION 5The thermostat provides a 4-minute delay after shutting off the compressor before it can be done while you begin to your...
...the entire installation section of your Hunter Thermostat. This Hunter Thermostat will prevent damage to install or operate your thermostat. It does not provide a delay when there are power outages. PROGRAMMING 3You can be restarted. OPERATION 4 Your Hunter Thermostat is normally performed at your Hunter Thermostat. • Remove the mylar ... control multistage heating or cooling systems, 110/220 V systems, or 3 wire zone systems. COMPRESSOR PROTECTION 5The thermostat provides a 4-minute delay after shutting off the compressor before it can be done while you begin to your...
Owner's Manual
Page 5
... batteries should be away from 32°F to 99°F (0°C to leaving. Once the "LOW BATT" indicator appears, the thermostat will display room temperatures from the premises over 30 days, we recommend that you plan to not operate properly. Rechargeable batteries have different properties... which may cause the thermostat to be used to operate for approximately 30 days. (Only alkaline batteries should last one year. BATTERY WARNING 8When the batteries are...
... batteries should be away from 32°F to 99°F (0°C to leaving. Once the "LOW BATT" indicator appears, the thermostat will display room temperatures from the premises over 30 days, we recommend that you plan to not operate properly. Rechargeable batteries have different properties... which may cause the thermostat to be used to operate for approximately 30 days. (Only alkaline batteries should last one year. BATTERY WARNING 8When the batteries are...
Owner's Manual
Page 6
... FAN RESET s To reset filter counter back to clean or replace your heating and air conditioning filters. s Reset Button For resetting thermostat. s Fan ON and AUTO Selector Switch. Features (Model 42999) 6-7 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature...
... FAN RESET s To reset filter counter back to clean or replace your heating and air conditioning filters. s Reset Button For resetting thermostat. s Fan ON and AUTO Selector Switch. Features (Model 42999) 6-7 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature...
Owner's Manual
Page 7
... or replace your heating and air conditioning filters. s Display backlight for viewing in the dark. s Fan ON and AUTO Selector Switch. s Reset Button For resetting thermostat. Features (Model 44050) 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature, set...
... or replace your heating and air conditioning filters. s Display backlight for viewing in the dark. s Fan ON and AUTO Selector Switch. s Reset Button For resetting thermostat. Features (Model 44050) 69 TEMP SET TEMP C FILTER LO BAT HOLD HEAT COOL s Easy-To-Read Digital Display Liquid crystal display shows room temperature, set...
Owner's Manual
Page 8
... have screws or other locking devices that open to removal. Some models have the following tools and materials. s Remove existing thermostat cover and thermostat. Once wall mounting plate is exposed, look for screws, tabs, etc. See Figure 1. To install your unit, you ... s Slotted screwdriver s Hammer s Electric drill and 3/16" bit s Two 1.5V (AA) Size Alkaline batteries Remove Old Thermostat CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. s If wires are not visible, they may be connected to the furnace at the main power...
... have screws or other locking devices that open to removal. Some models have the following tools and materials. s Remove existing thermostat cover and thermostat. Once wall mounting plate is exposed, look for screws, tabs, etc. See Figure 1. To install your unit, you ... s Slotted screwdriver s Hammer s Electric drill and 3/16" bit s Two 1.5V (AA) Size Alkaline batteries Remove Old Thermostat CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. s If wires are not visible, they may be connected to the furnace at the main power...
Owner's Manual
Page 9
TYPICAL HOME THERMOSTATS FIGURE 1 Wall Mounting Plate Thermostat Cover Wall Mounting Plate Thermostat Cover
TYPICAL HOME THERMOSTATS FIGURE 1 Wall Mounting Plate Thermostat Cover Wall Mounting Plate Thermostat Cover
Owner's Manual
Page 10
...the other wire to the W terminal to complete the circuit. s IMPORTANT! Installation 10-11 Label Wires s Each wire coming from the wall to the existing thermostat is connected to a terminal point on that no terminal marking on page 9. s After labeling wires, disconnect them to the wall. s If hole in ... is larger than necessary for heat only systems), as shown in Table A on the existing thermostat of two wire, heat only systems. Do not worry, just connect either of wires in your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these terminal points is often no hot or cold...
...the other wire to the W terminal to complete the circuit. s IMPORTANT! Installation 10-11 Label Wires s Each wire coming from the wall to the existing thermostat is connected to a terminal point on that no terminal marking on page 9. s After labeling wires, disconnect them to the wall. s If hole in ... is larger than necessary for heat only systems), as shown in Table A on the existing thermostat of two wire, heat only systems. Do not worry, just connect either of wires in your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these terminal points is often no hot or cold...
Owner's Manual
Page 11
If the code letter on your Hunter Thermostat. Wire Labeling This table will help you match the labels to the wires so you can attach them to thermostat Terminal shown RH RH RED RC RC BLUE G G GREEN Y Y YELLOW W W WHITE G or F Fan Y, C or M (See Note) Air Conditioning then mark wire with label shown RH RC G Y W or H Heating W TABLE A and connect to your existing thermostat is RH, R, VR or 4 24 Volt RC, VC 24 Volt Cool NOTE: Follow the labels when connecting wires since many installations do not follow color coding of wires.
If the code letter on your Hunter Thermostat. Wire Labeling This table will help you match the labels to the wires so you can attach them to thermostat Terminal shown RH RH RED RC RC BLUE G G GREEN Y Y YELLOW W W WHITE G or F Fan Y, C or M (See Note) Air Conditioning then mark wire with label shown RH RC G Y W or H Heating W TABLE A and connect to your existing thermostat is RH, R, VR or 4 24 Volt RC, VC 24 Volt Cool NOTE: Follow the labels when connecting wires since many installations do not follow color coding of wires.
Owner's Manual
Page 12
Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals. Installation 12-13 Wire Labeling (Continued) NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Tape up the wire and do not use. NOTE: Do not connect a "Common" wire (sometimes labelled "C") to any terminal on this thermostat.
Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals. Installation 12-13 Wire Labeling (Continued) NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Tape up the wire and do not use. NOTE: Do not connect a "Common" wire (sometimes labelled "C") to any terminal on this thermostat.
Owner's Manual
Page 13
Position wallplate on the bottom of the thermostat. Reposition wallplate to wall, pulling wires through large opening . Mark holes for appearance. Drill holes with 3/16" bit and gently tap anchors into wall anchor ... 2 Then level for plastic anchors provided if existing holes do not line up with wall. Insert mounting screws provided into the holes until flush with Hunter Thermostat holes. Mount Wallplate and Thermostat Snap open the wallplate from your thermostat by pressing the release tab on wall and pull existing wires through large opening .
Position wallplate on the bottom of the thermostat. Reposition wallplate to wall, pulling wires through large opening . Mark holes for appearance. Drill holes with 3/16" bit and gently tap anchors into wall anchor ... 2 Then level for plastic anchors provided if existing holes do not line up with wall. Insert mounting screws provided into the holes until flush with Hunter Thermostat holes. Mount Wallplate and Thermostat Snap open the wallplate from your thermostat by pressing the release tab on wall and pull existing wires through large opening .
Owner's Manual
Page 14
... Unless reset button is a switch on the Printed Circuit Board on as expected. Leave the switch in the cooling mode. Connect Wires and Mount Thermostat Cover to Wall Plate s Match and connect the labeled wires to the appropriate coded terminal screws on the Printed Circuit Board. s Heating system selector ...HG button is at "HG" position. In order to change to C° mode, slide the switch to C° and press reset button on when the thermostat calls for heat, change the mode. The switch is located near the display. NOTE: "HG" position is for gas and most other systems. "HE"...
... Unless reset button is a switch on the Printed Circuit Board on as expected. Leave the switch in the cooling mode. Connect Wires and Mount Thermostat Cover to Wall Plate s Match and connect the labeled wires to the appropriate coded terminal screws on the Printed Circuit Board. s Heating system selector ...HG button is at "HG" position. In order to change to C° mode, slide the switch to C° and press reset button on when the thermostat calls for heat, change the mode. The switch is located near the display. NOTE: "HG" position is for gas and most other systems. "HE"...
Owner's Manual
Page 15
... shows random numbers or partial HEAT OFF COOL AUTO FAN RESET digits, press the reset button once again. If it does not snap properly, the thermostat may be damaged. Press top of the wallplate. s The installation is in AUTO. RH RH RC RH G W Y FIGURE 3 FIGURE 4 ...FIGURE 5 s Insert the bottom tab on the thermostat body into hole to prevent interference with your house. s Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with...
... shows random numbers or partial HEAT OFF COOL AUTO FAN RESET digits, press the reset button once again. If it does not snap properly, the thermostat may be damaged. Press top of the wallplate. s The installation is in AUTO. RH RH RC RH G W Y FIGURE 3 FIGURE 4 ...FIGURE 5 s Insert the bottom tab on the thermostat body into hole to prevent interference with your house. s Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with...
Owner's Manual
Page 16
... will prevent memory loss and avoid reprogramming. s The thermostat will display room temperature from 40°F to 95°F. (5°C to 37°C). Replace batteries as soon as explained below. s Room temperature is current ... seconds, you will adjust the set from 32°F to 99°F. (0°C to 35°C). Reviewing Current Temperature Setting s 69° is displayed. s The thermostat is preset at the factory to your air conditioner compressor, caused by rapid cycling, by providing a delay of the...
... will prevent memory loss and avoid reprogramming. s The thermostat will display room temperature from 40°F to 95°F. (5°C to 37°C). Replace batteries as soon as explained below. s Room temperature is current ... seconds, you will adjust the set from 32°F to 99°F. (0°C to 35°C). Reviewing Current Temperature Setting s 69° is displayed. s The thermostat is preset at the factory to your air conditioner compressor, caused by rapid cycling, by providing a delay of the...
Owner's Manual
Page 18
72. 7 I. 70. Operations 18-19 Filter Monitor The Hunter Digital Thermostat measures and stores the amount of usage, the word "FILTER" will appear and flash on the display, reminding you to check or replace your system filter. 69 TEMP SET TEMP c FILTER LO BAT HOLD HEAT COOL The word "FILTER" will continue flashing until the filter counter is reset back to zero. 69 TEMP SET TEMP c FILTER LO BAT HOLD HEAT COOL After 500 hours of time the heating or air conditioning system operated.
72. 7 I. 70. Operations 18-19 Filter Monitor The Hunter Digital Thermostat measures and stores the amount of usage, the word "FILTER" will appear and flash on the display, reminding you to check or replace your system filter. 69 TEMP SET TEMP c FILTER LO BAT HOLD HEAT COOL The word "FILTER" will continue flashing until the filter counter is reset back to zero. 69 TEMP SET TEMP c FILTER LO BAT HOLD HEAT COOL After 500 hours of time the heating or air conditioning system operated.
Owner's Manual
Page 19
...reset, and the light will remain backlit for easy viewing of the display in the dark. Backlighting (Model 44050 only) Press LIGHT Your thermostat comes with an electroluminescent lamp for approximately five (5) seconds. If another button is pressed. If Filter button is pressed when "FILTER" ...displayed on the display. Note: Filter button works only when "FILTER" is not displayed, the internal counter will not reset. Temperature Span Your thermostat is reset, the "FILTER" disappears from the display. To Reset Filter Counter To Zero Press FILTER 69 TEMP SET TEMP c FILTER LO ...
...reset, and the light will remain backlit for easy viewing of the display in the dark. Backlighting (Model 44050 only) Press LIGHT Your thermostat comes with an electroluminescent lamp for approximately five (5) seconds. If another button is pressed. If Filter button is pressed when "FILTER" ...displayed on the display. Note: Filter button works only when "FILTER" is not displayed, the internal counter will not reset. Temperature Span Your thermostat is reset, the "FILTER" disappears from the display. To Reset Filter Counter To Zero Press FILTER 69 TEMP SET TEMP c FILTER LO ...
Owner's Manual
Page 21
Replace unit. ERRATIC DISPLAY 1. IF UNIT CONTINUES TO OPERATE IN OFF 1. If you experience any other problems, call 1-901-745-9222 from 8AM to 5PM Central Standard time for two seconds. POSITION THERMOSTAT READS , HI, LO PERMANENTLY 1. Then reprogram. Press the reset button once with a small pin and hold in for technical assistance. Replace unit.
Replace unit. ERRATIC DISPLAY 1. IF UNIT CONTINUES TO OPERATE IN OFF 1. If you experience any other problems, call 1-901-745-9222 from 8AM to 5PM Central Standard time for two seconds. POSITION THERMOSTAT READS , HI, LO PERMANENTLY 1. Then reprogram. Press the reset button once with a small pin and hold in for technical assistance. Replace unit.
Owner's Manual
Page 22
Wiring Diagrams 22-23 4-wire Heat/Cool System THERMOSTAT Jumper RC RH G W Y Heat/Cool Transformer Fan Heat Relay Cool Relay or Valve Contactor 5-wire Heat/Cool System THERMOSTAT RC RH G W Y Cool Heat Fan Heat Relay Cool Transformer Transformer Relay or Valve Contactor
Wiring Diagrams 22-23 4-wire Heat/Cool System THERMOSTAT Jumper RC RH G W Y Heat/Cool Transformer Fan Heat Relay Cool Relay or Valve Contactor 5-wire Heat/Cool System THERMOSTAT RC RH G W Y Cool Heat Fan Heat Relay Cool Transformer Transformer Relay or Valve Contactor
Owner's Manual
Page 23
2-wire Heat Only THERMOSTAT RC RH G W Y 3-wire Heat Only Heat Transformer Heat Relay or Valve THERMOSTAT RC RH G W Y 3-wire Cool Only Heat Fan Transformer Relay Heat Relay or Valve THERMOSTAT RC RH G W Y Cool Fan Transformer Relay Cool Contactor
2-wire Heat Only THERMOSTAT RC RH G W Y 3-wire Heat Only Heat Transformer Heat Relay or Valve THERMOSTAT RC RH G W Y 3-wire Cool Only Heat Fan Transformer Relay Heat Relay or Valve THERMOSTAT RC RH G W Y Cool Fan Transformer Relay Cool Contactor
Owner's Manual
Page 3
We are designed for buying a Hunter product. Table Of Contents Installation Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Operation Start-Up 16 Reviewing Current Temperature Setting 16 Setting New Temperature 17 Filter Monitor 18 Resetting Filter Counter To ...
We are designed for buying a Hunter product. Table Of Contents Installation Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Operation Start-Up 16 Reviewing Current Temperature Setting 16 Setting New Temperature 17 Filter Monitor 18 Resetting Filter Counter To ...