Installation Instructions
Page 1
... disposal of an old control. TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat APPLICATION INSTALLATION INSTRUCTIONS The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of properly. Check ratings given in the trash. TB7100A Thermostat Description. After installation is replacing ... 2 Pipe Fan Coil with Auxiliary Heat • 4 Pipe Fan Coil • PTAC (up to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool-Auto Auto, On Low, Medium, High Remote Setback Input for occupancy sensor or DDC setback ...
... disposal of an old control. TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat APPLICATION INSTALLATION INSTRUCTIONS The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of properly. Check ratings given in the trash. TB7100A Thermostat Description. After installation is replacing ... 2 Pipe Fan Coil with Auxiliary Heat • 4 Pipe Fan Coil • PTAC (up to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool-Auto Auto, On Low, Medium, High Remote Setback Input for occupancy sensor or DDC setback ...
Installation Instructions
Page 10
...coil or PTAC applications. 62-0273-05 10 Auto only for CNV, HP, PTAC and 4 pipe fan coil (ISU 0170). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Sensor/Remote program Setback/ mable) Changeover Input 0-None 1-Remote 10K Indoor 2-Remote 20K Indoor 3-Changeover 2 pipe Fan Coil... Temp 0 (Non- Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU 0170). NO input (default mode is Heat) NO input (...
...coil or PTAC applications. 62-0273-05 10 Auto only for CNV, HP, PTAC and 4 pipe fan coil (ISU 0170). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Sensor/Remote program Setback/ mable) Changeover Input 0-None 1-Remote 10K Indoor 2-Remote 20K Indoor 3-Changeover 2 pipe Fan Coil... Temp 0 (Non- Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU 0170). NO input (default mode is Heat) NO input (...
Installation Instructions
Page 13
... Pump and conventional use a single fan speed. Unoccupied heating (ISU 343) and unoccupied cooling (ISU 346) setpoints are manual changeover only. The default override time can manually be configured through ISU 342. OPERATION TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Sequence Operations (ISU 347, 348, 349) If heat pump or conventional application modes are...
... Pump and conventional use a single fan speed. Unoccupied heating (ISU 343) and unoccupied cooling (ISU 346) setpoints are manual changeover only. The default override time can manually be configured through ISU 342. OPERATION TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Sequence Operations (ISU 347, 348, 349) If heat pump or conventional application modes are...